Gaschromatographs

HP 5890 II GC with FID and NPD, Dual Split/splitle

Preis auf Anfrage
ID-number: 12305
Status: LabprocureLabprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.?
Shipping: 4-6 weeks
Description:
Specifications Heated devices. Five heated areas as standard: two detectors, two inlets, one auxiliary port. Stored Methods: Two. Split/splitless capillary. Temperature range up to 400°C in 1°C increments. Back pressure design allows independent adjustment of split flow rate without affecting column flow. Built-in septum rinsing at 3 ml/min. Accepts columns up to an outside diameter of 1.2 mm. Multi-mode design includes split and splitless injection. The splitless rinse time can be changed in 0.01 minute increments. Flame ionization detector. Temperature range up to 450°C. Grounded nozzle and current limiting design for operator safety. Flame ignition at the touch of a button. Sensitivities:. - 18 mCoul/gm Carbon:Nitrogen carrier, 0.018" ID nozzle. - 15 mCoul/gm Carbon:Helium carrier, 0.018" ID nozzle. - 22mCoul/gm Carbon:Nitrogen carrier, 0.018" ID capillary nozzle. - 18 mCoul/gm Carbon:Helium carrier, 0.018" ID capillary nozzle. Minimum detectable: 5 pg carbon/second, nitrogen carrier at S/N=2. Linear dynamic range: +/- 10% over a 10^7 range with 0.018" ID nozzle. -Conditions: Column flow 50 ml/min, 45 ml/min H2, 650 ml/min air, sampling with propane. Flame photometic detector. Temperature range up to 300°C. 100-530 u ID capillary columns fit through the transmission line to the base of the flame. Two combustion modes: air/hydrogen or oxygen/hydrogen. Display the detector signal to check whether the flame is burning. Flame ignition at the touch of a button. Sulfur mode: Sensitivity up to 20 pg S/second, range 10^3, selectivity 10^5 g S/g C. Phosphorus mode: Sensitivity up to 0.9 pg P/second, range 10^4, selectivity 10^6 g P /g C. Column oven. Operating range: 4°C above ambient temperature up to 450°C. Set point entry: 1°C for temperatures, 0.1°C for program rates. Programming: Rates from 0.1 to 70°C per minute, maximum run time of 650 minutes, three ramps with start/end hold times. This refurbished HP 5890 II GC with FID and NPD, dual split/splitless inlets is in great condition. Several available Labprocure is responsible for this device.
Quotation
More Information
Objektnummer C00012305
ID-number 12305
Object name HP 5890 II GC with FID and NPD, Dual Split/splitle
Status Labprocure Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.
Manufacture Hewlett Packard
Shipping 4-6 weeks

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Product group: GC

Back to Top
part-of-labexchange-group
Search engine powered by ElasticSuite
lazyOwllazyOwl
Labprocure