Specifications Heated devices. Five standard heated zones: two detectors, two inlets, one additional zone. Stored Methods: Two. Capillary split/splitless. Range up to 400°C in 1°C increments. The back pressure design allows the split flow rate to be adjusted independently without affecting the column flow rate. Built-in septum purge at 3 ml/min. Accepts columns up to 1.2mm outside diameter. Multi-mode design includes split and splitless injection. Splitless tracking time variable in 0.01 min increments. Thermal conductivity detector. Range up to 400°C. Single-filament design (for single column) has fluidic switching of reference and analyte carrier gas flows. Minimum detectable: 400 pg/ml carrier gas - equivalent to 1 ppm neon in 1 ml air. Linear dynamic range: +/- 5% over the 10^5 range. Digital gain setting can be time-programmed via the keyboard. Conditions: detector. -100°C, 45 ml/min switching flow and 30 ml/min analyte flow of helium, sample material propane. Flame photometric detector. Range up to 300°C. Capillary columns with an inner diameter of 100-530 µm fit through the transfer line to the base of the flame. Two combustion modes: air/hydrogen or oxygen/hydrogen. Detector signal display to detect when the flame is burning. Push button flame ignition. Sulfur mode: Sensitivity up to 20 pg S/second, range 10^3, selectivity 10^5 g S/g C. Phosphorus mode: Sensitivity up to 0.9 pg P/second, range 10^4, selectivity 10^6 g P/g C. Column oven. Operating range: 4°C above ambient temperature to 450°C. Enter the setpoints: 1°C for temperatures, 0.1°C for program rates. Programming: Rates from 0.1 to 70°C per minute, maximum run time 650 minutes, three ramps with initial and final stopping points. This reconditioned HP 5890 II GC with Dual TCDs, Dual EPC Controlled On-Column Inlets is in great condition Labprocure is responsible for this unit.
Quotation
More Information
Objektnummer C00012302
ID-number 12302
Object name HP 5890 II GC with Dual TCDs, Dual EPC controlled
Status Labprocure Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.
Manufacture Hewlett Packard
Shipping 4-6 weeks

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Product group: GC

Back to Top
part-of-labexchange-group
Search engine powered by ElasticSuite
lazyOwllazyOwl
Labprocure