HPLC-Systems

HP 1090 Liquid Chromatograph

Preis auf Anfrage
ID-number: 12265
Status: LabprocureLabprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.?
Shipping: 4-6 weeks
Description:
The reconditioned HP 1090 liquid chromatograph is in excellent condition. Specifications:. Solvent delivery system. Configuration: Isocrat, PV5 ter- or quaternary, DR5 binary or ter-. Areas:. Pressure: 0-400 bar (0-5880 psi). Flow: 0-5000 µl/min, in 1 µl/min increments. Flow Accuracy: +2% of set point or +1 µL/min, whichever is greater, regardless of back pressure and solvents, excluding volume contraction effects. Precision: <0. 3% RSD based on retention time. Composition. Precision PV5: +0. 25% absolute, peak to peak, water/acetonitrile, 500 µl/min, 2500 µl/min. Precision PV5: +0. 15% absolute, peak to peak, water/acetonitrile, 50 µl/min, 2500 µl/min. Delay volume. PV5: 1750-2000 µl maximum, depending on back pressure. DR5: 300-500 µl maximum, depending on back pressure. Heated area. Solvent and samples are preheated in a low volume heat exchanger (2 µl) with optional cooling for subambient operation. Adjustable temperature range: 0-100°C in 0.1°C increments. Temperature control range: 20°C above ambient to 100°C. Temperature stability: +0. 5°C. Injection system. Maximum pressure: 400 bar (5880 psi). Manual injector. Rheodyne valves 7125 or 7413, with loops from 0.5 µl to 100 µl. Autoinjector. Injection volume: -25 µl (standard) or 0. 1-250 µl (optional), in 0. 1 µl increments. Precision: <1% (typically 0.6%) RSD from 2-25 µl (25 µl syringe);. <1% (typically 0.6%) RSD of 10-250 µl (250 µl syringe). Sample vial: 0 mL standard, 300 disposable microvial, 100 µL microvial. Minimum sample quantity: 40 µl (2 mL standard vial), 20 µl (300 µl disposable microvial), 5 µl (100 µl microvial). Auto-Sampler: 10 removable magazines with 10 vials each (standard or microvials), with a random access time < 10 seconds from each position. Filter photometer detector. Filter: Interference filter 254 nm standard, 210, 230, 269, 280, 340, 430 and 540 nm optional. Bandwidth: typically 10 nm. Signal characteristics. Noise: 5x 10 E-5 AU. Drift: <1 x 10 E-3 AU/hour. Signal ranges:. Linear absorbance range: -0. 1 to 1.5 AU. Response time: 100, 400 and 800 (10-90%). Flow cell. Stainless steel cell with 4.5 µl volume, 6 mm path length and a maximum pressure of 100 bar (1470 psi). Diode array detector. Up to eight signals with definable sample and reference wavelength and bandwidth. Signal characteristics. Noise: +3. 5x10E-5AU. Drift: <2 x 10 E-3 AU/hour. Signal ranges:. Wavelength range: 190 – 600 nm, in 1 nm increments. Bandwidth range: 4-400 nm, in 1 nm increments. Linear absorbance range: -0. 1 to 1.5AU. Spectral ranges:. Wavelength range: 190 – 600 nm. Linear absorbance range: -0. 1 to 1.5AU. Scan time: 10 msec from 190-600 nm. Flow cells:. Standard cell: 8 µl, 6 mm, max pressure 120 bar. High sensitivity cell: 13 µl, 10 mm, max pressure 120 bar. Selectable slots: 2, 4 and 8 nm. We are professionals Labprocure is responsible for this device.
Quotation
More Information
Objektnummer C00012265
ID-number 12265
Object name HP 1090 Liquid Chromatograph
Status Labprocure Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.
Manufacture Hewlett Packard
Shipping 4-6 weeks

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Product group: HPLC

Back to Top
part-of-labexchange-group
Search engine powered by ElasticSuite
lazyOwllazyOwl
Labprocure