HPLC-Systems

Hitachi LaChrom ULTRA L-2455U Diode Array Detector

Preis auf Anfrage
ID-number: 12168
Status: LabprocureLabprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.?
Shipping: 4-6 weeks
Description:
The refurbished Hitachi LaChrom ULTRA L-2455U Diode Array Detector with Hitachi L-2200U Autosampler and Hitachi L-2300 Column Oven are in excellent condition. L-2455U DAD. Specifications: Light sources: D2 and W lamps, Hg lamp for wavelength calibration. Wavelength range: 190-900 nm. Noise: <0.25 x 10^-5 AU at 250 nm and 600 nm. Drift: <0.5 x 10^-3 AU/h at 250 nm and 600 nm. Slit width: 1 nm, 4 nm. Response time constants: 0.01/0.02/0.05/0.1/0.5/1/2 s. Data acquisition rates: shortest data interval 10 ms or 100 Hz. Standard cell: 5 mm / 3.2 µL. FDA/GXP functions: Automatic wavelength calibration with various D2 and Hg spectral lines. Maintenance log: data of the last lamp change (D2, W and Hg lamps), lamp energy, lamp usage, number of ignitions. In conjunction with the EZChrom Elite software: Documentation of the device serial number and configuration. Detailed audit trails and logs. L-2200U autosampler. Specification: Principle: Direct injection. Maximum pressure: 60 MPa (600 bar). Injection precision: < 0.3% RSD, typical: 0.1% RSD (10 µL). Sample cross-contamination: <0.005%. Linearity: correlation coefficient R^2 > 0.999. Sample capacity: 200 vials (1.5 mL) or 3 x 384 well microtiter plates. Injection volumes: 0.1 µL – 90 µL with a standard 100 µL syringe, up to 4.5 mL with optimal injection sets. Special functions: PASS: Pump autosampler synchronization. Advanced gradient function. Automatic pump piston flushing. Safety: leak sensor. Troubleshooting. Vial detection system. FDA/GXP features: Maintenance log: seal and valve usage, seal replacement data. In conjunction with the EZChrom Elite software: Documentation of the device serial number and configuration. Detailed audit trails and logs. L-2300 column oven. Specification: Range: [Room temperature - 15°C] to [Room temperature + 50°C]. Setting range: 1 to 65 °C. Accuracy: +/- 1°C. Safety: Built-in steam/leak sensor. Stability: +/- 0.1°C. Column Capacity: Up to three 25cm columns. GLP features: Serial number registration in device memory. Dimensions: 13.5" (W) x 15.75" (D) x 6.0" (H) (340mm (W) x 400mm (D) x 150mm (H)). Weight: approximately 22 pounds (10 kg) Labprocure is responsible for this device.
Quotation
More Information
Objektnummer C00012168
ID-number 12168
Object name Hitachi LaChrom ULTRA L-2455U Diode Array Detector
Status Labprocure Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.
Manufacture Hitachi
Shipping 4-6 weeks

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Product group: HPLC Systems

Back to Top
part-of-labexchange-group
Search engine powered by ElasticSuite
lazyOwllazyOwl