HPLC-Systems

Hitachi LaChrom Ultra L-2400U UV Detector

Preis auf Anfrage
ID-number: 12166
Status: LabprocureLabprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.?
Shipping: 4-6 weeks
Description:
The Hitachi LaChrom Ultra UPLC L-2400U UV detector specializes in fastest detection and extreme sensitivity. With extremely low detector response times of 10 ms, this detector can register even the narrowest and rapidly eluting peaks with high precision. It is based on the principle of the double beam photometer in conjunction with a rated monochromator and offers the highest possible sensitivity even with the fastest detector response times. Using the different spectral lines generated by the deuterium and mercury sources, wavelength calibration can be carried out over the entire wavelength range. Unlike calibration filters (e.g. holmium oxide), which must be calibrated themselves, the lamps' emission lines provide a primary reference standard, so they do not need to be recalibrated. For easy maintenance, all lamps and the flow cell are accessible from the front of the device. Specifications:. Type: Specifications Source: D2 lamp, Hg lamp for wavelength calibration. Wavelength range: 190-600 nm. Noise: <0.3 x 10-5 AU at 250 nm. Drift: <0.5 x 10-4 AU/h at 250 nm. Slit width: 6 nm. Response time constants: 0.01/ 0.02/0.05/0.1/0.5/1/2 s. Data acquisition rates: shortest data interval 10 ms or 100 Hz. Flow cell: 5 mm, 3.2 µL. FDA/GXP functions: Automatic wavelength calibration with different D2 and Hg spectral lines, Maintenance logbook: Date of last lamp change (D2, W and Hg lamp), lamp energy, lamp operating time, number of ignitions. Safety: Leak sensor, error handling. Dimensions (W x D x H): 34 x 40 x 15 cm Labprocure is responsible for this device.
Quotation
More Information
Objektnummer C00012166
ID-number 12166
Object name Hitachi LaChrom Ultra L-2400U UV Detector
Status Labprocure Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.
Manufacture Hitachi
Shipping 4-6 weeks

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Product group: HPLC

Back to Top
part-of-labexchange-group
Search engine powered by ElasticSuite
lazyOwllazyOwl
Labprocure