Sold

Hitachi L-7200

ID-number: 020633
Status: Stock unit
Preis auf Anfrage
Excl. 19% VAT , excl. Shipping Cost
siehe Storeview
Description:
Hitachi HPLC-autosampler L-7200. Unused.
Quotation
siehe Storeview
More Information
Objektnummer B00020633
ID-number 020633
Object name Hitachi L-7200
Status Stock unit

Product group: HPLC-Autosamplers

We can't find products matching the selection.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Merck-Hitachi

Modell:                         L-7200

Kommentar:     Dokumente engl.

Application

This instrument is used in combination with a liquid chromatography system to perform automatic analyses.

Configuration

The configuration of the L-7200 Autosampler is shown in Figure 3-1.

Samples to be analyzed are stored in a rack which is placed in a chamber that includes a syringe to allow aspiration of the samples can be moved along the transverse axis (X), the longitudinal axis (Y), and the vertical axis (Z). The injection valve is used to inject samples into the mobile phase flow. Syringes with a delivery volume of 0.1 and 0.5mL are available.

Analytical conditions are set via the keys on the keypad. The display panel presents information about the operational status of the system.

Flow path

Figure 1-3 includes the various components of the system that are

in contact with the sample and the wash solution in the L-7200

Autosampler. The needle can be moved along the X, Y and Z

axes to permit free movement between sample vials, the wash

port and the injection port. The action of the syringe is used to

withdraw sample from the sample vial and to deliver lt to the

injection port.

A cycle includes the following steps:

* The needle is cleaned in the wash port

* A sample solution is aspirated by the needle

* The sample solution is Ioaded into the loop of the injection valve

* The valve is switched to inject the sample into the mobile phase

Sample Injection Methods

The L-7200 permits three injection methods. In the standard injection method, the amount of sample that is withdrawn by the needle is slightly larger than the amount of sample that will be transferred from the injection valve to the column. The middle part of the sample is injected; the leading and trailing ends of the sample are not injected. This method is commonly called the cut injection method.

If the amount of a sample is small, the entire sample that is withdrawn via the needle is transferred into the sample loop and into the column. This method is called the all volume injection method.

In the full loop injection method, sample loop is filled with sample for measurement.

Cut lnjection Method

This method provides good reproducibility, however some of the sample is wasted.


Specifications

(1)      Number of standard samples: 80

         The vial number setting range is from 1 to 200

(2)      Rack/sample vials:

         Conditions can be set to accommodate a variety of sample vials and racks

(3)      Syringe capacity:

          0.5 mL (standard syringe)

(4)      Sample injection volume:

         0.5 pL to 400 pL (standard loop: 100 pL)

(5)      Syringe speed:

          5 speeds can be chosen by the analyst

(6)      Sample injection method:

          Syringe measurement cut injection

          Synnge measurement all volume injection

          Full loop measurement injection

(7)      Pressure resistance: 34 MPa (350 kgf/cm 2 )

(8)      Composition of components that are in contact with liquid:

         Stainless steel (SUS316), tetrafluoroethylene (Teflon), borosilicated glass,      Vespel, PEEK (polyethy lether ketone)

(9)      Display:

          LCD with back light (40 characters x 2 lines)

(10)    Control system:

          Sequential injection function for LC

(11)    Vial detecting function:

          Provided

(12)    Data storage:

          Battery backed-up memory

(13)    Number of injections per sample:

          Up to 99 times

(14)    Analysis time:

          999.9 minutes

(15)    Extemal communication function:

          D-Line communication

(16)    GLP function:

         Error detection: Abnormality in operation of the system is detectable.

         Maintenance logbook:      After part replacement, the number of injections is                                     recorded. The count can be reset to zero after certain                              parts (e.g. injection port seal) have been replaced.

(17)    Ambient temperature:

          4 to 35°C

(18)    Ambient humidity:

          45 to 85%

(19)    Power requirement:

          100- 240 V AC ± 10%, 50/60 Hz

(20)    Power consumption:

          Approx. 85 VA

(21)    Dimensions:    

          260(W) x 500(D) x 235(H) mm (excluding protrusions)

(22)    Weight:

          Approx. 19 kg

Part of labexchange logo