Hitachi F-2000

ID-number: 011884
Status: Archived Product?The unit is no longer available.
Shipping:
Description:
Hitachi Spectrophotometer F-2000. Wavelength: 220-730 nm. Xenon Source oflight with integrated Software and Printer. Can be supplied at once
siehe Storeview
More Information
Objektnummer B00011884
ID-number 011884
Object name Hitachi F-2000
Status Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Hitachi

Modell:            F-2000

Kommentar:    Dokumente engl.

The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representating the delivery volume. The exact delivery content you will find only in the offering text.

5-2 Optical System

Fig. 5-3 sketches the optical system configuration of the Model F-2000.

The radiation coming from the Xe lamp is converged at entrance slit S1 of the excitation monochromator through lenses L1 and L2. Only the light dispersed by the excitation concave grating (excitation beam) enters exit slit S2. The excitation beam from exit slit S2 is reflected by concave mirror M1 and the split into two by the beam splitter BS. The one of two excitation beams goes to the monitor detector for its measurement. And, the other beam (most of excitation) passing through BS is converged to the sample cell through lens L3.

The fluorescence coming out of the sample is restricted into entrance slit S3 of the emission monochromator through

lenses L4 and L5. The fluorescence dispersed by the emission concave grating passes through exit slit S4 and is converged at the photomultiplier via concave mirror M2 for intensity measurement.

The emission slit serves also as a shutter to protect the photomultiplier. It automatically closes upon opening the lid of the sample compartment.

Fig. 5-3            Optical System Configuration


Guaranteed Specifications

Light source

150 W xenon lamp with ozone seif-dissociation function

Monochromators

Large stigmatic concave grating having 900 lnes/mm used an both excitation and emission sides

o    Eagle mount             F: 3

o    Blaze wavelength     300 nm on excitation side

                                      400 nm on emission side

Measuring Wavelength Range

220 to 730 nm and 0-order light an both excitation and emission sides (though wavelength display is possible within 220 to 800 nm including 0-order light)

Wavelength Accuracy

Better than ±5 nm

Wavelength Scan Rate

15, 60, 240,1200 nm/min (4-step selection) (3000 nm/min in pre-scan mode)

Bandpass

o    Excitation side       10, 20 nm (2 steps)

o    Emission side        10, 20 nm ( )

Response speed

0.1, 0.5, 2 or 8 seconds for 0 to 98% response (Equivalent to a time constant of 0.025, 0.13, 0.5 or 2 seconds)

Photometric value indicating range

0.000 to 9999

Photometric principle

Monochromatic beam monitoring, ratio calculation

Minimum Sample Requirement

0.6 ml with use of the standard 10 mm cell

CRT

9-inch monochrome CRT display.

o    Contents of Display .. Measuring conditions, operating procedure, spectrum, etc.

Recorder

Thermal printer (Recording chart width : 110 mm)

Communication function

RS-232C bidirectional communication

Analog output

0 to 1 V at fullscale (12-bit D/A)


Data processing functions

o    Pre-scan

o    Quantitative calculation

          2- or 3-wavelength calculation

          Calibration curve generation (up to ten kinds of standard samples)

          Repetitive measurement averaging (up to ten times)

          Calibration curve correction/storage Time integration

o    Spectral measurement

          Peak detection

          Enlargement/reduction of graph

          Spectra storage (two spectra)

o    Time-varying measurement

          Peak detection

          Rate calculation

          Enlargement/reduction of graph

          Data storage (two spectra)

Measurement condition storage

Up to 20 parameters

(Auto start under user-defined measurement conditions is available.)

Dimensions

500 (W) x 730 (D) x 500 (H) mm

Weight

Approx. 50 kg

Power requirements.

100, 115, 220, 230, 240 V AC, 50/60 Hz

Power Consumption

400 VA (50/60 Hz usable)

Performance-guaranteed Temperature Range

5 to 35°C

Performance-guaranteed Humidity Range

45 to 80%