Hitachi 911
| Objektnummer | B00010927 |
|---|---|
| ID-number | 010927 |
| Object name | Hitachi 911 |
| Status | Stock unit |
Product group: Clinical chemistry
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
|
Country |
Possible payment methods |
Comment |
|
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
|
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
|
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
|
Status |
Condition |
Comment |
|
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
| In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
|
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
|
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
|
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Firma: Hitachi
Nachfolgende Abbildungen und Beschreibungen sind modellbezogen und aus Prospekten entnommen.
Sie geben nicht den Lieferumfang des Systems wieder.
Den exakten Lieferumfang entnehmen Sie bitte aus dem Angebotstext.
Spezifikationen
System
Durchsatz 360 Tests/Stunde, (720 Tests/Stunde mit ISE)
Anzahl gleichzeitig möglicher Tests 32 (35 mit ISE)
Anzahl möglicher chemischer ParameterAnzahl 46 (49 mit ISE)
Anzahl möglicher Testausgaben 57 (60 mit ISE)
Probenspeicher 49 Tests x 800 Routineproben (52 mit ISE) und
49 Tests x 200 Eilproben (52 mit ISE)
Probenvolumen 1 bis 50 µI (in 1 µl Schritten)
Reagenzvolumen 50 bis 350 µl (in 1 µl Schritten)
Küvettenfüllvolumen min. 250 bis max. 500 µl
Levelsensor-System In jeder Proben- und Reagenznadel
Rührer Mischen nach jeder Reagenzzugabe
Probenteller Anzahl Postionen: 115
Routineproben: 50
Standardproben: 34
Eilproben: 20
Kontrollproben: 8
Waschlösungen: 3
Probencup Kunststoff
Probencupvolumen max. 2 ml
Mikrocupvolumen max 500 µl
Reagenzteller R1 und R2 Teller je 33 Flaschen (incl. Hitergent 33)
Reagenzflaschenvolumen 20, 50 und 100 ml
Reagenzkühlung alle Reagenzien bei 5 bis 15°C
Reaktionsteller 120 Küvetten
Küvettenmaterial Kunststoff
Schichtdicke 6 mm
Küvettenreinigung Automatisch
Fotometer 12 Wellenlängen von 340 bis 800 nm (mono- oder bichromatisch). (340, 376, 415, 450, 480, 505, 546, 570, 600, 660, 700, 800 nm)
Linearer Extinktionsbereich 0 bis 3,3 Ext.
Reaktionszeit max. 15 Minuten. Die Anzahl der Meßpunkte hängt von der Meßzeit ab. (3, 4, 5, 10 oder 15 Minuten je nach Testauswahl.)
Reaktionstemperatur 37°C ± 0,1°C
Meßarten 1-Punkt-, 2-Punkt-, 3-Punkt-Messung, 2-Punkt-Kinetik,
1-Punkt und Kinetik, Kinetik -A-und Kinetik -B-.
Kalibrationsarten Linear, Nichtlinear, mit K-Faktor, Isoenzym
Berechnungsfunktionen Kalkulation und Kompensation.
Monitorfunktionen Reaktionsmonitor und Datenmonitor, Kalibrationsliste, Kalibrationskurve und -verlauf
Qualitätskontrolle Real time QK (mit Ausdruck), tägliche QK und kumulative QK
Datenausgabe Analysenergebnisse, Arbeitsliste, Rerunliste, Kalibrationsliste, Fotometercheck, Original Ext., Reaktionsverlauf, Kalibrationsverlauf. Präzisionscheck, Alarmliste, Hardcopy aller Bildschirme, etc.
Diskettenlaufwerke 2 x 3,5 Zoll HD
Drucker 80 Zeichen/Zeile
Monitor 14", Farbmonitor
Systemschnittstelle RS 232 C
Spannungsversorgung 100, 115, 127, 220, 230, 240 Volt Wechselspannung
Leistungsaufnahme 3 kVA
Erdung max. 10 Ω
Raumtemperatur 15 bis 32°C (± 2°C während der Messung)
Luftfeuchtigkeit 45 bis 85% relative Luftfeuchtigkeit
Dest. Wasserdruck 0,5 bis 3,5 bar (49 bis 343 kPa)
Dest. Wasserverbrauch ca. 30 I/h Leitfähigkeit < 1 µS / cm
Abfluß max. 1 Meter Höhe, min. 50 mm Durchmesser
Abmessungen Analyzer: 1030 mm Breite, 760 mm Tiefe, 1170 mm Höhe
Bedieneinheit: 480 mm Breite. 650 mm Tiefe, 1250 mm Höhe
Gewicht ca. 350 kg