Heraeus HB 2448 K
Objektnummer | B00018379 |
---|---|
ID-number | 018379 |
Object name | Heraeus HB 2448 K |
Status | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.
Description
A Class II cabinet consists of a confined work space in which a stable parallel flow (laminar flow) provides protection against cross-contamination between the surroundings, the operator and the product. All operations take place through the work opening. Sub pressure in the work chamber draws room air into the cabinet through the work opening and down through the suction holes in the front of the tabletop. By this the operator is protected against possible emission of harmful substances from the product with which the operator is working.
Technical description
Air movements:
Via the work opening room air is drawn in through the perforated area in the front part of the tabletop. The vertical superfiltered airflow from the main filter separates in the middle so that the air is partly sucked down through the perforated area in the front part of the tabletop and partly sucked down through the perforated area in the rear edge of the work chamber. The total amount of air is mixed below the tabietops.
Prefilter (on HBB only):
Degree of detention 99.99% of particles 0 0.3 pm (DOP-test). (The mixture of air from the work chamber and the work opening is filtered).
Fan:
The air is led to the fan placed in the top of the unit. The fan is of a seif-compensating type and has thus only an insignificant drop in the quantity of air by an increase in backpressure. By means of a built-in transformer the fan can be made to operate with increased power.
The air is then led to the pressure plenum. 25% is exhausted to the room through exhaust filters. 75% is led over the main filter and forms the unidirectional flow in the chamber.
Exhaust filter:
Filter efficiency 99.999% of particles 0 0.3 pm (DOP-test).
Main filter:
Filter efficiency 99.999% of particles 0 0.3 pm (DOP-test).
Alarms:
Exhaust
The unit has an alarm for too little exhaust air. The supervision takes place via pressure measuring over the exhaust filter - see also the paragraph concerning operation.
Front window
lf the front window is not in working position, i.e. if it is open or placed above the horizontal green marking, this is indicated by an alarm signal.
Technical data
|
HB 2448/ HBB 2448 |
H |
315 mm |
L |
1265 mm |
D |
Ø 160 mm |
Weight |
200/225 kg |
Capacity of trough |
10/6 l |
Quantity of exhaust air (nominal) |
400 m 3 /h |
Dry heat emitted (recirculation to room) max. |
530 W |
Dry heat emitted (recirculation to room) nominal |
335/465 W |
Dry heat emitted (exhaust to the outside) |
100 W |
Mains voltage |
220(115)* V |
Mains frequency |
50(60)* Hz |
Current intensity |
2 Amp |
Max. load an wall sockets |
6 Amp |
Required mains cutout |
10/16 Amp |
Sound pressure Ievel** (re 20 µPa) |
<55 dB(A) |
Sound Power evel***(re 1 pW) |
60/61 dB |
* Optional ** According to DIN 12950 Teil 10 *** According to DIN 46535 Teil 1 Klasse 3 (ISO 3746) |
|
Property of materials
Subjects Material Treatment
Front windows and side windows Clear polycarbonate
Window frames PVC
Upper part, return duct and Mild-steel plate 60 µm polyestercoating pre‑
bottom part ST 1203 DIN 16023 treated to corrosion class 1
Stand Iron pipe 60 µm polyestercoating pre
treated to corrosion class 1
Trough, tabletops and suction gate Stainless steel AISI 304 Polished
Functional parts of the cabinet
( 1) Valves*
( 2) Electrical outlet
( 3) Charcoal filter (4) Main filter
( 5) Centrifugal fan
( 6) Mains connection
( 7) Anti blowback valve*
( 8) Box containing the electrical parts
( 9) Exhaust filter
(10) Lamp cover
(11) Pressostats
(12) Control panel
*(13) Light fittings
*(14)Front window
(15) Work chamber
(16) Cover plate, front**
(17) UV-light*
(18)Trough
(19) Tabletops (tabletop*)
(20) Stand for HB tabletop version
(21) Stand for HB floor model
(22) Prefilter an HBB
(23) Levelling screws.