Hach DR 2800
Objektnummer | B00015203 |
---|---|
ID-number | 015203 |
Object name | Hach DR 2800 |
Status | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Company: Hach
Model: DR 2800
The following illustrations and descriptions are model-based and drawn from brochures.
Do not give the delivery volume again.
The exact delivery content you will find only in the offering text.
Applications |
Municipal and industrial wastewater, drinking water, Surface water, water treatment, process water, Production control |
Modes |
Absorbance (± 3 E), transmission (%), concentration |
Wavelength Range |
340- 900 nm (tungsten lamp) |
Reference beam technology |
To compensate for lamp aging and power fluctuations |
Integrated Barcode |
For automatic identification of LANGE cuvette tests |
Reading System (IBR) |
incl. 10-fold rotational measurement for elimination of outliers |
Cuvettes |
Cell holder for LANGE cuvette tests with IBR system Cell holder for rectangular cells 10 mm, 50 mm, 1 inch and 1 inch round cuvettes |
Display |
High resolution LCD (320 x 240 pixels) Backlighted, Touchscreen |
Data storage |
Up to 500 measured values; 50 user-specific methods More than 200 preprogrammed HACH LANGE methods and |
Interfaces |
USB interface for PC, printer, USB Stick Optional: Software for direct data transfer to PC |
Protection |
IP41 |
Mains connection |
100 -120 V; 200 -240 V; 50/60 Hz; automatic switching; incl. plugs for all European power networks |
Battery (optional) |
Lithium-ion battery for up to 40 hours of operation |
Ambient temperature |
10 - 40 ° C, 0 - 90% rel. Humidity |
Dimensions (WxHxD) |
22 x 33.2 cm x13,7 |
Weight |
4 kg (without battery) |
Subject to change.