Gossen Pointax 6000 M

ID-number: 015853
Status: Archived Product?The unit is no longer available.
Shipping:
Description:
Gossen Dotted-line recorder Pointax 6000 M.
siehe Storeview
More Information
Objektnummer B00015853
ID-number 015853
Object name Gossen Pointax 6000 M
Status Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Firma:                   Gossen

Modell:                Pointax 6000 M

Kommentar:        Dokumente deut.

Nachfolgende Abbildungen und Beschreibungen sind modellbezogen und aus Prospekten entnommen.

Sie geben nicht den Lieferumfang des Systems wieder.

Den exakten Lieferumfang entnehmen Sie bitte aus dem Angebotstext.

POINTAX 6000M

Punktschreiber

Verwendung

Der konfigurierbare Punktschreiber POINTAX 6000M dient zur Registrierung von veränderlichen Prozeß-Meßgrößen. Gleich­strom, Gleichspannung, Thermoelemente sowie Widerstands­thermometer (Pt 100) können direkt angeschlossen werden.

Auf dem Registrierpapier lassen sich zusätzlich freie alphanumeri­sche Texte, Datum, Uhrzeit und Ereignisse ausdrucken. Der Schreiber ist für den Einbau in Schalttafeln vorgesehen.

Wesentliche Merkmale

•            6 Meßkanäle

•            Letzter Punkt von vorne sichtbar

•            Mit Textausdruck

•            Meßkanäle galvanisch getrennt und erdfrei

•            Format 144 mm x 144 mm, Einbautiefe 250 mm

•            Kombischreibtisch für Rollenpapier (32 m) oder Faltpapier (16 m)

•            Schnittstelle RS 485

•            2 Grenzwertei . e Meßkanal

•            Bilanzierung

•            4 Ereignismarken

•            Alternativ einsetzbar als Ereignisschreiber mit 10 Ereignismarken

Beschreibung

Der POINTAX 6000M ist ein mikroprozessor-gesteuerter Punkt­schreiber. Er wird in zwei unterschiedlichen Versionen geliefert.

Skalenausführung mit 1 bis 6 Skalenteilungen

Displayausführung

Der Schreiber wird an Meßumformer und/oder direkt an Meßwert­aufnehmer wie Thermoelemente oder Widerstandsthermometer angeschlossen.

Die Anpassung des Schreibers an die Meßaufgabe erfolgt über das interne Tastentableau oder über die serielle Schnittstelle mit­tels PC und Parametrierprogramm PARATOOL P6000M

Zusatzfunktionen wie Textausdruck, Datum, Uhrzeit, Bilanzierung und Ereignismarkierungen erhöhen den Informationsgehalt der protokollierten Prozeßgrößen. Alarmsignalisierung und Fernsteu­erfunktionen machen den POINTAX 6000M zu einem vielseitig einsetzbaren Gerät.

Die Standby-Funktion gestattet getriggerten Registrierbetrieb.

Technische Daten

Analoge Eingänge, Nennbereiche

Gleichstrom                     0...20 mA;           Ri = 50 Ω

                                        4...20 mA;           Ri = 50 Ω

                                         ± 2,5 mA,           Ri = 50 Ω

                                            ± 5 mA;           Ri = 50 Ω

                                          ± 20 mA;           Ri = 50 Ω

Gleichspannung             0....25 mV;           Ri ≥ 2 MΩ

                                          ± 25 mV;           Ri ≥ 2 MΩ

                                      0    100 mV;           Ri ≥ 2 MΩ

                                        ± 100 mV;           Ri ≥ 2 MΩ

                                      0...500 mV;           Ri ≥ 2 MΩ

                                          0...2,5 V;           Ri ≥ 200 kΩ

                                            ± 2,5 V;           Ri ≥ 200 kΩ

                                          0...5,0 V;           Ri ≥ 200 kΩ

                                            ± 5,0 V,           Ri ≥ 200 kΩ

                                             ± 10 V,           Ri ≥ 200 kΩ

                                             ± 20 V,           Ri ≥ 200 kΩ

Thermoelemente,          Typ T -270... +400 °C

Ri > 2 M Ω                      Typ U -200... +600 °C

                                      Typ L -200.. . +900 °C

                                      Typ E -270... +1000 oC

                                      Typ J –210... +1200 °C

                                      Typ K –270... +1400 °C

                                      Typ S     -50... +1769 °C

Thermoelemente,          Typ R -50... +1769 °C

Ri > 2 MÜ                       Typ B      0... +1820 °C

                                      Typ N –20... +1300 °C

Vergleichsstelle intern oder extern parametrierbar, Fühlerbruchüberwachung parametrierbar

Widerstandsthermometer     -50 ... +150 °C;

Pt 100                                     -50 ... +500 °C;

                                              -200 ... +850 °C

bei 2-Leiterschaltung   Leitungswiderstand maximal 40 Ω

bei 3-Leiterschaltung   Leitungswiderstand maximal 80 Ω

Analoge Eingänge, Meßbereiche

Meßbereichsanfang                von Xl n ... XI n + 0,8(X2n - Xl n) und

Meßbereichsumfang               von 0,2(X2n - XI n) ... (X2n - Xl n) parametrier­bar.

Tote Zone                                 0,25 % vom Meßbereichsumfang

Einstellzeit                                1 s

Druckzykluszeit                       für alle Kanäle 3 ... 360 s wählbar

Meßwertdämpfung                  mit Tiefpaß 1. Ordnung;

Zeitkonstante                            0 ... 60 s je Meßkanal, parametrierbar.

Radizierfunktion                      bei Gleichstrom- und Gleichspannungs-Nenn­bereichen parametrierbar.

Anwender-Linearisierung

bei Gleichstrom- und Gleichspannungs-Nenn­bereichen parametrierbar.

Referenzbedingungen

Umgebungstemperatur            25 °C ± 1 K

relative Feuchte                       45 ... 75 %

Hilfsspannung                          Hn ± 2 %, Nennfrequenz ± 2%

Einbaulage                               Front senkrecht ± 2°

Anwärmzeit                              30 min

Genauigkeit

Meßabweichung nach DIN IEC 484                   Klasse 0,5 bezogen auf den Nennbereich

Bei Verschiebung von Meßbereichsanfang       ±   (0,1 % x X2n – X1n/X2 – X1 - 0,1)

und/oder Meßbereichsende zusätzlich            

bei interner Vergleichsstellenkorrektur              ± 4 K zusätzlich

Einflußeffekte

Temperatur                                    0,2 % 10 K, zusätzlich

                                                      0,1 % 10 K bei Thermoelementanschluß

Luftfeuchte                                     Einfluß auf Registrierpapier nach DIN 16234 beachten.

Hilfsspannung Hn                           0,1 % bei 24 V DC/AC ± 20

0,1 %bei 24 VAC +10%/-15 % 0,1 %bei 115VAC +10%/-15 % 0,1 %bei 230 V AC 40 % / -15 %

Störwechselspannungen (siehe zulässige    0,5 % des Meßbereichsumfangs Störspannungen)

magnet. Fremdfeld 0,5 mT            0,5 % des Meßbereichsumfangs

mechanische Beanspruchung      während und nach der Einwirkung

nach DIN IEC 68-2-6/27                 ± 0,5 % des Meßbereichsumfangs

Transport      Stoß: 30 g/18 ms

                      Schwingen: 2 g/5...150 Hz

in Funktion     Schwingen:

                      0,5 g/± 0,04 mm/

                      5...150 Hz/3 x 2 Zyklen

Product group: Recorders