Gilson M 156

ID-number: 012340
Status: Stock unit
Preis auf Anfrage
Excl. 19% VAT , excl. Shipping Cost
siehe Storeview
Description:
Gilson UV/VIS-Detector M 156. 2-channel. Wavelength: 190-700 nm. With Analytical Cell 12 µl. YoC: 2000. Can be supplied at once.
Quotation
siehe Storeview
More Information
Objektnummer B00012340
ID-number 012340
Object name Gilson M 156
Status Stock unit

Product group: HPLC-Detectors (UV/VIS)

We can't find products matching the selection.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Gilson

Modell:            M 156

Kommentar:    Dokumente engl.

The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representating the delivery volume. The exact delivery content you will find only in the offering text.

Gilson's 15X Series of UV/VIS Detectors deliver versatile, rugged detection for your HPLC. The optical design lets you optimize the detection of your sample at any wavelength from 190 to 700 nm.

•     Interchangeable flow cell design accommodates capillary to preparative HPLC applications

•     The detectors have a sensitivity range of 0.001 to 2.0 AUFS (Absorbance Units, Full Scale)

•     Controlled via Gilson’s UniPoint™ System Software or choose stand-alone keypad control with the 151 and 155 models

•     Stores up to 10 detection methods

•     Choose from the following modes to specify detection conditions and basic operating parameters:

     – single wavelength

     – file

     – status

     – setup

     – dual wavelength (155 and 156)

     – scan wavelength (155 and 156)

Specifications

Manufacturing Standards                  Meets applicable safety and EMC certification      standards; UL and CE certified

Autozero Range                                  Suppresses up to 1.0 AU with 5 mm flow cell installed

Communication Interface                   Event and autozero inputs; remote contact closure can   be activated by other instruments or the computer.                                                               Three channels output data to a recorder.

Drift                                                       After 1 hour at constant temperature: 3.0 x 10-4 AU/hr

Environmental Conditions                 Indoor use

                                                              Altitude: up to 2000 m

                                                              Temperature range: 5–40°C

                                                              Air pressure: 75–105 kPa

                                                              Pollution degree: 1 or 2, in accordance with IEC 66

                                                              Humidity: Maximum relative humidity 80% for       temperatures up to 31°C, decreasing linearly to 50%                                                               relative humidity at 40°C

Flow Cell Assemblies                         The following quartz flow cells are available:

                                                             Flow Cell             Path (mm)       Volume (µL)        psi

                                                             Analytical              5                       12                         500

                                                             Microbore             2                       1.6                        500

                                                             Preparative           0.2                    0.7                        500

                                                             Preparative           0.05                  0.16                      500

Flow Sensitivity                                   4.0 x 10-4 AU for flow step of 2.0 mL/min to 0.5 mL/min with methanol

Front Panel                                          Four-line display shows modes, parameters,       commands, and data. Six soft keys and HELP, ESC,                                                               CLEAR, ENTER, numeric, and arrow hard keys   (151/155 only). LED indicator lights for POWER,    UV,VIS, REMOTE, and ERROR. LAMP ON/OFF hard         key.

Lamps                                                   UV lamp: Deuterium, warranted for 750 hours or 180       days

                                                              Visible lamp: Tungsten/halogen, warranted for 500          hours

Lamp Warmup Time                            One hour maximum

Linearity                                               1%, when value is within sensitivity range of 0.001 to       2.0 AU

Monochromator                                   Dual beam, stepper motor-driven

                                                              • Range: 190–700 nm

                                                              • Spectral bandwidth: 9 nm

                                                              • Setting accuracy: ±2 nm

                                                              • Setting precision: ±0.2 nm

Noise with Air Block Installed           220 nm, short term, peak to peak, 2.0 x 10-5 AU/cm;       254 nm, short term, peak to peak, 2.0 x 10-5 AU/cm;                                                               350 nm, short term, peak to peak, 10.0 x 10-5 AU/cm;     415 nm, short term, peak to peak, 8.0 x 10-5 AU/cm;                                                               520 nm, short term, peak to peak, 6.0 x 10-5 AU/cm;       650 nm, short term, peak to peak, 4.0 x 10-5 AU/cm

Peak Width                                           0 and 4 to 99 seconds for single- or scan-wavelength      mode; 4 to 99 seconds for dual-wavelength mode

Power Requirements                         Frequency: 50–60 Hz

                                                              Voltage: 90–120 or 220–240V; mains voltage        fluctuations not to exceed ±10% of the nominal voltage
                                                              Current rating: 1.0A for 90–120V, or 0.5A for 220–             240V
                                                              Online switching regulation of line input from 80 to           260V AC

Sensitivity Range                                0.001 to 2.0 AU. Sensitivity is adjustable in increments    of 0.001 AU

Software Control                                 Via GSIOC or RS-232. You can issue commands to do the following:

                                                              • Select all detection parameters

                                                              • Program parameter changes during run to optimize      detection

                                                              • Send digital detector output

Static RI Sensitivity                            Methanol versus cyclohexane at 270 nm: 5.0 x 10 -3         AU

Temperature Sensitivity                    3.0 x 10-4/°C for temperature change from 21° to 24°C

Dimensions (w x d x h)                       26.5 x 43.5 x 15.6 cm (10.4 x 17.1 x 6.2 in.)

Weight                                                  8.6 kg (19 lbs.)