Genitron Mini CX-3
| Objektnummer | B00017204 |
|---|---|
| ID-number | 017204 |
| Object name | Genitron Mini CX-3 |
| Status | Stock unit |
Product group: Beta counters / Gamma counters
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
|
Country |
Possible payment methods |
Comment |
|
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
|
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
|
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
|
Status |
Condition |
Comment |
|
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
| In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
|
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
|
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
|
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
manufacturer : Genitron
model : Mini CX-3
annotation : Dokumente engl.
The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.

The Geiger counter measures beta, gamma, x-ray and neutron radiation wich a muck greater sensitivity than conventional Geiger counters and proben.
Easy to use for both teachers and students: just switch it an and read off the value. Direct quantative display (from 0 to 30µSv/h). Individual pulsen indicated optically and acoustically. Loud warning tone at approx. 50 µSv/h .
An electronic control System ensures that the unit functions reliably in daily use. All elements are designed for maximum shock resistance.
Areal of application:
The Geiger counter has proven indispensable wherever radioactivity and x-ray radiation must be measured quickly and precisely: in research and industry, in medicine and dentistry, in educational applications, civil defence, public and private security Services, mineral prospecting and environmental protection.
Technical data
Geiger counter
Housing: Shock-resistant plastic, with wrist strap
Dimensions: 155 mm x 72 mm x 42 mm
Weight: Approx. 350 g (incl. battery)
Operating temperature range: -5 to +50 °C
Power supply: Standard 9-volt battery; rechargeable block battery or lithium
cells may also be used.
intensity
Measured value display: 0 - 30 µSv/h
0 - 3 mR/h
Measuring accuracy: ± 30 %, calibration with Cs-137
Pulse indication: 3 kHz tone and light flach for each pulse.
The pulse counter 667 919 can be connected to the locket on the front via the connecting Gable
Warning threshold: Constant tone at approx. 50 gSv/h
Electrical function monitoring: EPC-system for disturbance monitoring
Radiation detector
Type: Proportional detector, self-quenching
Design: End-window counter tube,
extremely stable
End-window material: Metal-plastic laminate
approx . 100 mg/cm 2
Effective measuring area: 104 mm x 32 mm
Detectable radiation: gamma/x-ray 20 keV‑
2 MeV, uncompensated, beta from 500 keV
Pulse counter
Housing: Impact-resistant plastic
Dimensions 155 x 72 x 42 mm
Weight: approx. 170 g Operating temperature range 0 to +50 °C
Power supply:
Measured-value display: 6-digit LC-display
Measuring accuracy: ± 1 pulse
Internat timer: 100 kHz-Quartz (type TX) Measurement
intervals : Automatic: 1 min. or 10 min.
Manual: Any length
Conventional radiation measuring Instruments use counter tubes, which haue a relatively small counting volume due to their round design. Devices of this type are not suitable for measuring weck radiation.
For this reason, this unit employs a detector technology which is characterized by exceptionally high detection sensitivity: The sandwich proportional counter tube SPZ-03.
The production method applied here permits not only the inexpensive manufacture of large-volume detectors, but also the best possible match to the dimensions of a hand-held device.
This internationally patented technology has proven itself time and again in actual practice.