Fujifilm Dri-Chem 3500i
| Objektnummer | B00017106 |
|---|---|
| ID-number | 017106 |
| Object name | Fujifilm Dri-Chem 3500i |
| Status | Stock unit |
Product group: Clinical chemistry
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
|
Country |
Possible payment methods |
Comment |
|
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
|
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
|
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
|
Status |
Condition |
Comment |
|
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
| In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
|
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
|
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
|
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
manufacturer : Fujifilm
model : Dri-Chem 3500i
annotation : Dokumente engl.
The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.


The Fuji Dri-Chem 3500 series is a dry chemistry analyzer for analyzing blood and urine. The Fuji Dri-Chem 3500 series has 2 types as follows:
Fuji Dri-Chem 3500i: With potentiometric unit on basic type
Using the Fuji Dri-Chem Slides, the FDC3500i can perform colorimetric end-point, rate, and potentiometric tests. Also, the FDC3500s can perform colorimetric end-point and rate tests, but potentiometric tests.
Specifications
FUJI DRI-CHEM 3500i: With PM unit an basic type
Through put: 60 tests/hour (CM), 140 tests/hour (PM),
77 tests/hour (simultaneous CM and PM tests)
Number of incubator's cells: CM 6, PM 1
Incubation time: 1 - 6 minutes
Incubation temperature: 37.0 ± 0.2°C (98.6 ± 0.36°F )( CM)
30.0 ± 1°C (86.0 ± 1.8°F)
or environmental temperature +2°C (+3.6°F) (PM)
Number of slides
that can be loaded at a time: 20
Sampler
(1) Pipetting fluid volume-. Below 50µL (automatic switching)
(2) Tip ejector: Automatic ejection
(3) Dilution: Automatic dilution (dilution factor: max. 21)
Slide ejection: Automatic ejection (max. 80 slides in the disposal box)
Used tip ejection: Automatic ejection (into the disposal box)
Measurement wavelengths: 400 nm, 505 nm, 540 nm, 577 nm, 600 nm, 625 nm, 650 nm
Light source: Halogen lamp (6V, IOVV)
Measurement precision: 0.0004 OD/5 minutes
Measurement accuracy: ± 0.002 OD (600 nm)
Indications: LCD (back lit), 16 characters, 1 line
Indicator lights (CARD, ABC, VV, P/S, U )
Printer Thermal type (paper size: 58 mm x 25 m)
Warnring up time: Approx. 10 minutes/25°C (77°F), approx. 20 minutes/15°C (59°F) Environmental conditions
Location: Indoor use [limited below 6000 (* 3000) cd/m2 (lux)]
(* when using the sample bar-code reader)
Attitude: Up to 2000m
Transient overvoltage category: II
Pollution degree: 2
Operating temperature: 15 to 32°C (59 to 89°F)
Operating humidity: 30 to 80% RH (no dew condensation)
Storage and transportation conditions
Temperature: -10 to 50°C (14 to 122°F)
Humidity: 10 to 90% RH (no dew condensation)
Electrical requirements:
Nottage limit-. 100 - 240V ~
Frequency: 50 - 60 Hz
Supply voltage fluctuations: ± 10%
Rated wattage: 350VA
Type of protection against electrical
shock : CLASS1 EQUIPMENT
Data transfer: RS-232C serial Interface
External dimensions: 400 (W) x 385 (D) x 280 (H) mm
Weight: 19kg