Sold

Foss NIR-System 5000-II

ID-number: 021726
Status: Stock unit
Preis auf Anfrage
Excl. 19% VAT , excl. Shipping Cost
siehe Storeview
Description:
Foss NIR spectrometer 5000-II. DCA 5000. Reflection detector module. Reflection measurement liquids. 3 cuvettes of Suprasil quartz glass. VISION chemometrics software. Maxdata XP laptop with Microsoft Office and VISION programs.Color Printer Canon IP 3000. YoC 2002
Quotation
siehe Storeview
More Information
Objektnummer B00021726
ID-number 021726
Object name Foss NIR-System 5000-II
Status Stock unit

Product group: NIR-Spectrometer

We can't find products matching the selection.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Foss

Modell:            NIR-System

Kommentar:   Dokumente engl.

The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.

Direct Contact Analyzer

Direct Contact Analyzer consists of:

Monochromator (System II) (Model 6500 monochromator for 400-2500nm coverage)

Reflectance module

Horizontal setup module

Sample centering iris

Vision software for material identification, qualification, and quantification

Features and Benefits

•            Non-destructive analysis of solids and liquids

•            Direct analysis through unopened containers, such as bags, beakers, bottles, or vials

•            No sample preparation, no hazardous reagents, no waste

•            Raw material identification and qualification

•            Final product assay

System Description

The Direct Contact Analyzer offers rapid chemical analy­sis and physical parameter testing without opening the sample container. The analyzer accepts unopened con­tainers such as plastic bags, beakers, vials, and bottles.

Operation is based an NIR (near-infrared) technology which is completely non-destructive. The Direct Contact Analyzer returns each sample unharmed for further test­ing, if wanted. The Direct Contact Analyzer is a nonfiber-based system which allows for use of the entire

wavelength region to 2500 nm. And, the NIR measure­ment process is completed in about 45 seconds. Imagine the time savings and manufacturing efficiency when comparing NIR with HPLC, FTIR, and Karl Fischer methods.

The Direct Contact Analyzer is a true multipurpose ana­lyzer and can be used to analyze powders, liquids, or finished dosage forms without changing the instrument. Scanning from 400nm to 2500nm permits measurement of product color variance in every test, without extend­ing the analysis time.

Measure incoming raw materials for identification and qualification in seconds. The NIR method will eliminate the need for most other tests, and reduce the time in quarantine from days to minutes. And because NIR is a "green" technology there aren't any solvents or dispos­al Problems. Nothing is consumed, the sample remains completely uncontaminated, and there is nothing to dispose of after the test.

Specifications

Scan Rate                               1.8 Scans/second

Wavelength Range                 400-2500nm (Wide-Range Mode)

Wavelength Accuracy             ±0.3nm (Basis: Polystyrene Standard peaks 1100-2500nm)

Wavelength Repeatability      ±0.010nm (Standard Deviation of 10 consecutive scans 1100-

                                               2500nm)

Noise (peak-to-peak)               <2.0 (400-700nm)

                                               <.25 (700-2500nm)

Noise (RMSAvg)                      <.2 (400-700nm)

                                               <.02 (700-2500nm))

Spectral Bandwidth                 10 ± 1 nm

Photometric Range                 3.0 Au (1100-2500nm)

Linearity (2% to 99%               +1.0%

reflectivity or transmissivity)

Stray Light                               <0.1% at 2300nm

Operating Temp. Range         15°C to 33°C (60°F to 92°F)

Power Consumption               150 watts (maximum)

Dimensions:

Width:                                      15,25” (388mm)

Height:                                     21.5” (546mm) from bench to top instrument

Depth:                                     11,6” (295mm) front to back

Weight.                                    42.0 pounds (18.9kg)

Minimum Computer Requirements

Pentium processor, 32 Mbyte RAM, 100 Mbyte available HD space, VGA or higher Monitor,

32-bit Windows operating system (Windows 95 or NT 4.0), 3.5 Floppy disk drive, serial port and parallel port.


SmartProbe Analyzer

This system can analyze powders and liquids directly in less than one minute. It can perform quantitative analysis, identification, and qualification of mate­rials easily, quickly, and accurately.

The SmartProbe uses near-infrared . (NIR) spectral energy to illuminate the sample. By measuring the energy reflected off the sample, chemical Infor­mation and composition can be assayed.

NIR measurement is inherently non-destructive, so the sample is available for later use, re-analysis, or verification. Sample preparation is not required, which saves time, enhances accuracy and precision, and uses no chemicals.

The SmartProbe, used in conjunction with fiber optic technology, provides a simple and convenient method for direct analysis of many materials. The SmartProbe Analyzer is available with standard fiber lengths of 2 meters and 3 meters.

Menu-driven, validated Vision® Spectral Analysis Software permits use of the SmartProbe for identification, qualification, and quantitative measurement. Features such as password security, automatic data logging, and a full audit trail meet the rigorous requirements of regulated industries.

The SmartProbe handle contains an easy-to-read LED panel to guide the Operator through use of the system for sampling. Because the Computer may be two to three meters away from the material being sampled, this panel indicates when the system is ready (or is performing) the sampling functions. Use is explained in section 5.0.

This SmartProbe manual is designed to guide the user through instrument assembly and set-up, and to successful communication with the host PC. Full instruc­tions for use of Vision are found in the manual accompa­nying the software, and in help screens.

1.0 Introduction

Thank you for purchasing the

SmartProbe manufactured by FOSS. This system can analyze powders and liquids directly in less than one minute. It can perform quantitative analysis, identification, and qualification of mate­rials easily, quickly, and accurately.

The SmartProbe uses near-infrared (NIR) spectral energy to illuminate the sample. By measuring the energy

reflected off the sample, chemical Infor­mation and composition can be assayed.

NIR measurement is inherently non­destructive, so the sample is available for later use, re-analysis, or verification. Sample preparation is not required, which saves time, enhances accuracy and precision, and uses no chemicals.

LED indicators on the SmartProbe handle provide operator

Information about the analyzer and sample results.

Dimensions

Width:              17,5” (445mm) with SmartProbe in holster

Height:             15,0” (381mm) from bench to top of SmartProbe

Depth:              21,0” (534mm) front to back, not counting cords

Weight:            40.4 pounds (18,2kg)

Part of labexchange logo