Description:
Erlab Filter exhaust Captair Filtair 936. 230 V 50 Hz 94 W. Safety Class 2. Exhaust air 200 m³/h. 960-961 filter. Security Class 3. Class of contaminant retention capacity, 2 fans. Analog current meter. Noise level about 51 dB (A). External dimensions: 110x84x74 cm. Internal dimensions: 87x82x73 cm. No own worktop. Two penetrations in the windshield. CE marked. YoC 2001
siehe Storeview
More Information
Objektnummer B00019473
ID-number 019473
Object name Erlab Captair Filtair 936
Status Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Firma:                   Erlab

Modell:                Filtair 936

Kommentar:        Dokumente deut.

Nachfolgende Abbildungen und Beschreibungen sind modellbezogen und aus Prospekten entnommen.

Sie geben nicht den Lieferumfang des Systems wieder.

Den exakten Lieferumfang entnehmen Sie bitte aus dem Angebotstext.

Entsprechend KLASSE 11 der Norm AFNOR NFX 15-211

Vorteile

Vollkommener Anwenderschutz

Filtrationssicherheit : Alle Modelle der captair@ filtair - Filterabzug entsprechen der Norm AFNOR NFX 15-21 1 Klasse II.

Schadstoffrückhaltevermögen der Dämpfe von Chemikalien im Arbeitsraum, garantiert durch die Kontrolle der Luftgeschwindigkeit an Fassade und die Einhaltung der Normen zur Schadstoffrückhaltung (XPX 15203, BS 7258, DIN 12927)

Probennahmeventil für die ausgestoßene Luft ermöglicht dem Anwender jederzeit die Kontrolle der Filtersättigung anhand von Farbreaktionsröhrchen (nicht im Lieferumfang enthalten).

Frontseite und Tür aus Acryl schützen vor eventuellen Chemikalienspritzern (Feuerklassifizierung, Norm NF P92.507)

Ergonomie und Komfort

Schräge Frontseite für eine bessere Übersicht über den Arbeitsgang. Durchdachte Öffnungen für die Hände geben dem

Anwender viel Bewegungsfreiheit im Arbeitsraum.

Stopfbuchsen für das Einführen von Elektro- oder Stromkabeln in den Arbeitsraum.

Arbeitsposition an den Anwender angepasst.

Geräuschpegel sehr niedrig (49 dBA).

Durchsichtige Wände für einen guten Überblick über die Arbeitsgänge im Arbeitsraum.

Einfache Installation / Energieersparnis

Keine Abluftleitung, es genügt eine Steckdose.

Direkte Installation in Ihrem Labor oder auf einem optionalen

mobicap"- Rolltisch.

Energieersparnis, durch das Recycling der gereinigten Luft aus dem Gerät ohne Verbrauch beheizter oder gekühlter Luft.

Technische Daten

Filtair 936

Filter MF

Filter VF

Luftumsatz m 3 /Std.

200

130

Lufteintrittsgeschwindigkeit Frontseite m/s

0,51

0,50

Volumen des Arbeitsraumes m 3

0,432

Gesamte Stromstärke Watt

94

Stromaufnahme A

0,62

Geräuschpegel dB(A)

51

Innen-Maße mm

817x875x735

Außen-Maße mm

871x1100x763

Verfügbare Filter

MF und VF

Standardausrüstung

Luftgeschwindigkeitsmesser

Stopfbuchsen

Handbuch der zurückgehaltenen Chemikalien: Chemical Listing

Stundenzähler

Probennahmeventil

Ergonomische Öffnung

Optionale Ausrüstung

Securifilter

Arbeitsfläche mit Auffangbecken

Durchsichtige Rückwand

Beleuchtung

Rolltisch Mobicap

Product group: Filtration

We can't find products matching the selection.
Back to Top
part-of-labexchange-group
Search engine powered by ElasticSuite
Labprocure