Erlab/Captair PCR-workbench Biocap DNA. Static work space. Internal dimensions: 600x601x565 mm. Working space of acrylic glass. UV lamp with timer. Power supply: 230 V, 50 Hz, 26 W. Brandnew! Manufacturer s warranty. On request a roll table and outdoor lightning is available at an additional cost. The workbench can also be ordered as DNA / RNA Workbench with HEPA filters H14.
Quotation
siehe Storeview
More Information
Objektnummer B00005719
ID-number 005719
Object name Erlab Biocap DNA
Status Stock unit

Product group: PCR

We can't find products matching the selection.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

manufacturer :       Erlab

model :                   Biocap DNA

annotation :           Dokumente engl .

 

 

 

 

 

 

 

Strengths

 

Captair ® solutions are designed to protect laboratory personnel when working with chemicals. Based on the principle of filtration, these products offer a high degree of protection against the inhalation risks posed by the harmful molecules and particles emitted in the workstation.

The containment and filtration effectiveness of these products, as demonstrated by their compliance with the AFNOR NF X 15-211: 2009 standard, make this shared protective equipment a reliable, flexible, economical, and environmentally-friendly solution.

 

Protect the environment

Free of any ducted airflow system, Captair ® solutions eliminate the direct emission of pollutants into the atmosphere and help to protect the environment. They also avoid the pollution generated as a result of the energy needed to run the airflow systems of traditional ducted fume hoods.

 

Eliminate installation costs

Implementing a Captair ® solution is simple and quick. It does not involve the installation of a ventilation system for air supply and extraction as required by ducted systems.

A single electrical outlet is all you need to run the Captair ® Flex® fume hood. It can be installed at any time, without complex preparation.

 

Save on energy costs

The air balance necessary to run ducted systems results in high energy consumption. A Captair ® solution eliminates the energy costs related to systems for extracting and supplying conditioned air. It is able to keep operating costs low, even when the cost related to filter replacement is taken into account.

 

Easily transportable and instantly ready to use

Captair ® solutions may be moved from one location to another within the same laboratory according to protection needs. They can be easily relocated without affecting the air balance of the equipment.

 

 

 

 

Quality design

 

With over 90,000 Captair ® units in operation, our internationally-recognized experience allows our developers to design solutions that optimize the workstation and the handling of chemicals. This experience enables us to offer product lines that provide security, functionality, and comfort in terms of both use and maintenance.

 

Enclosure dimensions

  • Enclosure width: from 80 cm to 180 cm
  • Large instruments can easily be placed inside
  • Easy to integrate with current laboratory fixture

 

Visibility

  • The optical-quality synthetic glass panel provides optimal visibility of the activities performed within
  • bright lighting

 

Openings on the front

  • Ample room for movement within the enclosure
  • Central protective screen to prevent any risk of chemical splashes

 

Installation

  • Ready to install, quick assembly
  • Very few tools required
  • Simple maintenance operations

 

Working posture

  • Activities can be performed either seated or standing, without fatigue
  • Rounded-edge work surfaces: provide an armrest for the forearms
  • Slanted front comfortable working posture

 

Quiet operation

 

 

 

 

Captair ® Bio

PCR workstations

 

Designed for gene amplification applications, Captair ® Bio PCR workstations allow users to save precious time by offering a contamination-free work environment needed to duplicate samples.

Equipped with a powerful UV-ray system and a vertical laminar flow, these work stations provide a high degree of protection for the applications performed within.

 

 

 

 

Biocap TM DNA static enclosure

 

For applications with little risk of sample contamination

 

Dimensions (mm)

Interior             L           601

                        D          565

                        H          600

Exterior           L           653

                        D          610

                        H          730

 

Technical specifications

Acrylic enclosure                                          10mm

Internal volume of the enclosure                  0,2m³

Total electrical power                                   26 Watts

Voltage/frequency                                        230V/50Hz

 

 

 

 

Biocap TM RNA-DNA dynamic enclosure

 

The ultra-clean air entering the enclosure meets the requirements of ISO class 5 (standard EN ISO 14-644), which corresponds to American class 100 (i.e., less than 100 particles per cubic foot * )

 

* When used in a cleanroom in compliance with ISO 9/EN 14-644 standard

 

For application with a high risk of sample contamination

 

Dimensions (mm)

Interior:            L           601

                        D          565

                        H          600

Exterior          L           653

                        D          610

                        H          785

 

Technical specifications

Acrylic enclosure                               10mm

Filter type                                           HEPA HI4

Face velocity                                     0,53m/s

Internal volume of the enclosure      0,2m³

Air flow rate                                       175m³/h

Air renewal                                        90 time/min

Voltage/frequency                             230V/50Hz

Electrical power                                73 Watts

 

 

 

 

 

 

 

 