Eppendorf BioPhotometer
Objektnummer | B00017802 |
---|---|
ID-number | 017802 |
Object name | Eppendorf BioPhotometer |
Status | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
manufacturer: Eppendorf
model: Bio Photometer
annotation: Dokumente engl .
The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.
Features
§ Ready to use at all times
§ Self-explanatory, extremely simple operation
§ Compact design, easy to transport
§ Robust housing, splashand water-resistant
§ Measurement only takes approximately two seconds
§ High-quality components guarantee high operating reliability
§ Metal housing ensures stability
§ Optional: Software package for online data transfer to a PC
§ Optional: Secondary UV-VIS filter for testing the BioPhotometer
Technical data
Optical system
Absorption, single-beam photometer with reference beam
Light source
Xenon flash lamp
Light beam height
8.5 mm
Spectral range
220 to 750 nm
Wavelengths
Xe 230; 260; 280; 320; 562; 595 nm
Spectral range width
5 nm: 230 to 320 nm; 7 nm: 562 to 595 nm
Photometric measuring range
0.000 to 3.000 A
Photometric accuracy
±1 % at 1 A
Photometric precision
≤0.002A at 0A; ≤0.005A at 1A
Method-dependent evaluation
o Absorbance / concentration using factor
o Concentration using calibration with 1 to 10 standards
o One-point calibration (1 std) / linear regression (2 to 10 standards)
o Non-linear regression ( polynome 3rd degree; 4 or 5 standards), 1x, 2x or 3x determination
o 260/280 ratio, 260/230 ratio, molar concentration, total yield
o Warburg formula for direct protein A280
Calibration memory
For protein methods
Result memory
For 100 results with absorbance, ratio values, sample no., dilution, date and time
Printer interface
RS 232 C, serial, for printer or PC with BioPhotometer software package
Power consumption
Approx. 20 W in operation; approx.10 W in standby mode
Power connection
Europe (230 V, 50/60 Hz), Switzerland (230 V, 50 Hz), UK/Hong Kong (230 V, 50/60 Hz),
North America (120 V, 60 Hz), Australia (240 V, 50 Hz) or Japan (100 V, 50/60 Hz)
Dimensions / Weight
Width 20 cm: depth 32 cm: height 10 cm / approx. 3 kg
Cuvettes
UV ette and common rectangular cuvettes of suitable glass or plastic materials