Elementar Vario Macro
Objektnummer | B00021973 |
---|---|
ID-number | 021973 |
Object name | Elementar Vario Macro |
Status | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Firma: Elementar
Nachfolgende Abbildungen und Beschreibungen sind modellbezogen und aus Prospekten entnommen.
Sie geben nicht den Lieferumfang des Systems wieder.
Den exakten Lieferumfang entnehmen Sie bitte aus dem Angebotstext.
Gerätespezifikation vario MACRO
Funktionsprinzip
Verbrennungsmethode bei 850°-1200°C (1800°C durch Verbrennung in Zinnbehältern, gewichtsabhängig)
Purge-and-trap Gastrennung und WLD Detektion
Betriebsarten / Versionen
N, CN, CNS, CHN, CHNS
(Aufrüstbarkeit N auf CN, CN auf CNS, CHN auf CHNS)
Optionen für die Bestimmung von O sowie Cl
gemäß
AOAC 990.03, AOAC 993.13, AOAC 968.06, AOAC 992.15,
AOAC 992.23, ASBC, AACC, (für Dünger, Fleisch, Fleischprodukte,
Getreide, Ölsaaten, Brauereigetreide, Mehl, Futtermittel)
DIN 10 467 Milch und Milchprodukte EN 61010,
DIN/ISO 13878 (Boden), LUFA, MEBAK (Brauereien),
ASTM D5373-93 (C, H, N in Kohle und Koks)
ASTM D5291-91 (C, H, N in Ölprodukten und Schmierstoffen)
gemäß Sicherheitsstandard
CE-Zeichen (EMC & und Niederspannungsrichtilinien)
IEC 1010, DIN EN 50081-1/2, DIN EN 50082-1/2
Messbereiche
C: 0,002% bis 100% (oder max. 100 mg abs.) *
N: 0,004% bis 100% (oder max. 100 mg abs.) *
H: 0,015% bis 100% (oder max. 15 mg abs.) *
S: 0,004% bis 100% (oder max. 15 mg abs.)*
O: 0,05% bis 5 mg abs. *
Cl: 0,1 50 µg abs.
Einwaage
bis ca. max. 1,5 g bzw. bis 1 g Boden oder 500 mg organisches Material *
Präzision
Ф 0,5% RSD (für 100 mg Testsubstanz, z. B. Glutaminsäure)
Analysenzeit
selbstoptimierend, abhängig von Elementgehalt und Gewicht
z. B. 4 Min. für N in 100 mg Glutaminsäure,
6 Min. für CN in 100 mg Bodenprobe
Probengeber
39 Positionen (Standard), für Probenvolumen bis zu 1 cm 3
79 Positionen (optional) bis ca. 150 mg Probe
Gase
He: 99,995 % Reinheit
O2: 99,995 % Reinheit
Gerätesteuerung und Messwertverarbeitung
externer PC unter Windows®
automatischer Lecktest, Fehlerdiagnose, Wartungszyklen, Statistiken, Schlaf-/Weckfunktion, LIMS kompatibel;
entspricht den Anforderungen § 21 CFR Part 11 (Option)
elektrische Anschlüsse
110/230 VAC, 50/60 Hz, 1.8 KW
Abmessungen
78 cm x 56 cm x 62 cm (B X T X H)
Gewicht
ca. 120 kg
Stand: 10/2004, Änderungen vorbehalten
* abhängig von Probenart und -größe sowie Betriebsmodus