Archive

Dynex MRX

ID-number: 022058
Status: Archived Product?The unit is no longer available.
Shipping:
Description:
Dynex Microplate reader 96-well MRX. Filter: 405, 450, 490, 620, 690 nm. Computer. Laserprinter. Screen.
siehe Storeview
More Information
Objektnummer B00022058
ID-number 022058
Object name Dynex MRX
Status Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

 

manufacturer:     Dynex

model:                  MRX

 

 The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.

 Specifications

 

Software Specifications                              MRX e Standard: Revelation MRX Program

Hardware Specifications                             No. of filters 6

Performance Read:                                    cycle time Single Wavelength: < 4 seconds;  Dual Wavelength: < 6 seconds

405 to 850nm Wavelength

Range Dynamic range                               -0.100 to +4.000 OD

Linearity                                                      0.000 to 2.000 OD: ± 1.0%;            2.001 to 3.500 OD: ± 1.5%

Filter band width (FWHM)                          10 nm ± 2 nm

Center Wavelength Accuracy                     ± 2 nm

Precision                                                     0.000 to 2.000 OD: 0.2% CV or 0.005 OD whichever is greater

                                                                    2.001 to 3.000 OD: 0.6% CV

                                                                    3.001 to 3.500 OD: 1.0% CV

Accuracy                                                     0.000 to 3.500 OD: 2.5% or 0.005 OD whichever is greater

340 to 400 Wavelength

Range (Option) Dynamic range                  -0.100 to +3.000 OD

Linearity                                                       0.000 to 2.500 OD: ± 2.0%

Filter band width (FWHM)                           18nm ± 2 nm

Center Wavelength Accuracy                     ± 2 nm

Precision                                                     0.000 to 2.000 OD: 0.6% CV or 0.005 OD whichever is greater

                                                                    2.001 to 2.500 OD: 1.0% CV . 

* Precision is the mean Coefficient of Variation (CV) figure for all wells on a plate that has been read 20 times in succession. (Measured by the manufacturer at 410nm in the visible range and 340nm in the UV range).

Interface Computer

Interface                                                      USB 1.0/2.0 compatible

Electrical                                                      Light source 75W tungsten halogen lamp

Mains input                                                  100 to 120V or 200 to 240V 50 to 60 Hz (switch selectable)

Power consumption                                     175 VA

Fuses                                                           There are no internal user-replaceable fuses. The power supply contains a CSA approved 20x5mm, 4A cartridge fuse with a voltage rating of 250V in

                                                                     the primary circuit. If the fuse blows, contact the service center.

Physical/Environmental Conditions

Weight                                                          10.kg (22.lb)

Dimensions                                                   D390 x W360 x H220 mm (15.4 x 14.2 x 8.7 inches)

Operating Temperature                                10 – 40°C

Operating Humidity                                       10 – 90% RH

Storage Temperature                                    0 – 50°C

Storage Humidity                                           10 – 90% RH

Altitude                                                          < 2000m

Product group: Microplate-Devices

We can't find products matching the selection.
Back to Top