Archive

DiaSorin Max 3000

ID-number: 012248
Status: Archived Product?The unit is no longer available.
Shipping:
Description:
DiaSorin Microplate Analyzer Eti Max 3000. For ELISA and EIA. With Table. PC. YoC: 2001. As new
siehe Storeview
More Information
Objektnummer B00012248
ID-number 012248
Object name DiaSorin Max 3000
Status Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Firma:             DiaSorin

Modell:           Max 3000

Kommentar:  Dokumente engl.

 

The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.

The ETI-MAX 3000 is a fully automated microtiter plate analyzer performing the complete sample processing (sample pre-dilutions, sample and reagent dispensing, incubations, wash processes, plate transports) as well as the photometric measurement and evaluation. The Instrument is controlled via the Windows PC software ETI-MAX 3000. This software, which was specifi­cally designed for this purpose, allows the user to process the pre-defined assays of DiaSorin as well as assays programmed by the user. The clear structure with intuitive user-guidance allows simple and quick operation of daily routine jobs as well as programming of user-specific assays.

 

Figure 1: Instrument modules

 

1          Tray for tip racks and dilution tubes

2          Patient samples and reagent unit

3          Tip eject station, pipettor rinsing position, pipettor station

4          Test plate compartment, plate transport unit

5          Drawer with wash unit and photometer

6          Position of incubators (below the tost plates), heated and for room tem­perature (dark)

7          Waste container for tips

8          Guide rail for pipettor (X and Y movement)

9          Pipettor (movement in Z-direction)

 

 

Technical Data

System Overview

Number of plates                             Up to 4 plates at once

Number of samples                         Max. 100 tubes, up to max. 0 16 mm, length up to 200         mm

Number of reagents                         Special racks for DiaSorin reagents

Dilution positions                             Positions for up to 160 dilution tubes

Number of tips                                 Up to 5 tip racks for 300 µl or 1100 µl disposable tips

Loading                                            Continuous loading of plates, samples, reagents and tips

 

Photometer

Spectral range                                 400 - 700 nm

Dynamic range                                -0.100 to 3.000 OD

Accuracy                                          ± 0.005 or 2.5%

Linearity                                           0 - 2.000 OD ±1%

Detection                                         Photodiode

Reading time                                   < 15 seconds

Read modes                                    OD and Kinetic mode

Filters                                               Up to 8 positions

 

Pipetting System

Pipettor                                            Liquid pipettor for disposable tips

Liquid level detection                       Standard

Min Max volumes                             10 µl to 300 µl or

1000 pl with large tips Accuracy      < 3 % at 10 µl

                                                         <0.5%at100pl

Precision                                          < 3 % CV at 10 µl

                                                         < 2.5 % CV at 100 µl

Features                                          Tip detection, mixing, multi-dispensing mode

 

Incubation

Capacity                                           4 independent chambers

Temperature range                          Minimum temperature = RT + 5

                                                         Maximum temperature = 50°C

Accuracy                                          ± 1° C mean of plate

Uniformity                                         ± 0.7° C across plate

 

Operatinq conditions                    Room temperature during Operation.

 

Washing

Capacity                                           Max. 3 positions wash buffer + 1 distilled water

Wash head                                      1 x 8 with verify option

Dispense volume                             200-2500 µl/well

Precision                                          ± 5% CV at 300 µl

Residual volume                              < 2.5 µl in U-shaped bottom

                                                         < 4 µl in flat bottom

Fluid alarms                                     Low reagent, waste full

Features                                          Sweeps, soak, purge, top & bottom wash, variable pump     speeds

 

Bar Code                                        Barcode identification of samples, reagents and test            plates possible

 

Software features

Operating system                            Windows 95

Interfaces                                         ASTM interface

                                                         Flexible ASCII import of worklist sample ID's

Time Scheduling                              Schedules 4 plates with user options

Multiple assays per plate                 Up to 12 assays per plate

Export options                                  Flexible ASCII export and report

Qualitative                                        User definable result classes

Quantitative                                      Linear to quadratic regression, sigmoidal, and many more

Language support                            Multiple languages possible

QA analysis                                     Mean, SD, CV, Standard Error and Levey-Jennings

 

Power Supply

Universal a.c. input                          100 - 260 Vac, 47 - 63 Hz

                                                         Typically max. 500 VA

Dimensions

W x D x H in mm                             <1060x660x835

Weight                                             90 kg

Product group: Sampling devices