Description:
Cellomics Screening System ArrayScan II-C. Cytoplasm to Nucleous Translation. Cell Viability. Neurite Outgrowth 5 x and 10 x magnification. Store Base Software. SQL-Server. YoC: 2000.
Quotation
siehe Storeview
More Information
Objektnummer B00009695
ID-number 009695
Object name Cellomics Array Scan II-C
Status Stock unit

Product group: Life science / Biotechnology

We can't find products matching the selection.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Cellomics

Modell:            Array Scan II-C

Kommentar:   Dokumente engl.

The ArrayScan II System is the first automated High Content Sereening (HCS) platfonn designed for multicolor fluorescence-based screens in standard microplate formats using whole cells that are analyzed individually or on a population basis. The ArrayScan II System is based on wide field epifluorescence cell imaging using fluorescence-based reagents incorporated into and/or on the surface of cells. The system incorporates automated cell identification, focusing, measurement, and analysis capabilities for multiple cellular targets and processes occurring over space and time. Multiple fluorescence markers are detected by fully automated successive recording of each fluorophore with optimized optical filter sets to achieve efficient color separation. Incorporation of a pre-aligned Mercury-Xenon lamp with a 1500 hour lifetime bulb decreases instrument down-time and enables "around-the clock" functionality.

The system also includes application software that affords immediate and powerful screening capabilities, with the flexibility to customize assays easily and quickly. Each biological application comprises a collection of optimized algorithms that automate the extraction and quantification of assay-specific biological information from cell images collected on the ArrayScan II System.

Technical Specifications

ArrayScan II Instrument

Input Voltage/Frequency         100-115VAC, 50-60 Hz –or-

                                               220-240VAC, 50 Hz

Power Consumption               6A max at 110-115V

                                               3A max at 220-240V

Computer Interface                 RS-232 serial (double shielded)

Microplates                              Most clear bottom plates are compatible

Plate Scan Region                  Rectangular area of plate, including all user defined well(s).

Stage Scan Region                 Up to a 120 mm by 100 mm rectangular area are can be   scanned with an XY resolution of 0.2 microns, and repeatability                                                of 1-2 microns.

Focus                                      Automatic for each image.

Focus Resolution                    Automatically adjusted for selected objective lens. Smallest          focus increment is 0.1 microns.

Illumination                              Mercury-Xenon illumination unit.

Wavelength Range                 350-700 nm

Filter Changers                       Automated 6 position excitation filter wheel. Manual 4 position       dichroic filter /emission filter slider.

Standard Filter Sets                Four channel fluorescence filter set with excitation at [center-        wavelength (full width at half maximum)] 365(50), 485(15),                                  546(10) and 655(30) and emission at 460(15), 520(20) and           603(30) and 710(20) for Hoechst, Fluorescein, Rhodamine and                      Cy5 fluorophores respectively.

                                               Two channel fluorescence filter set with excitation at [center-         wavelength (full width at half maximum)] 475(40) and emission                                 535(45) for Hoechst and GFP fluorophores respectively.

Max# of Channels                   6 (in a single protocol)

Camera                                   High-resolution, thermoelectrically cooled, digital camera with       12-bit dynamic range.

Optics                                      5x, 10x, and 20x objective lenses

Fuses                                      Voltage            Specifications                                     Quantity

                                               100-115 V        3AG, 250V, 8A, Fast Acting Type                 2

                                               220-240 V        3AG, 250V, 4A, Fast Acting Type                 2

Options

Additional Optics                     Optional objective magnification of 40x is available.

Additional Filters                      Filter sets are available for most fluorophores.

Robotic Plate Stacker

General

Power Requirements              2A max current

Fuses                                      Voltage             Specifications                                        Quantity

                                               120V                 3AG, 250V, 1.5A, Fast Acting Type              1

                                               240V                 5x20 mm, 250V, 0.8A, Fast Acting Type      2

Plate Capacity                         19-20 plates depending on plate manufacturer.

                                               Optional High Capacity Stacker holds up to 80 plates.

Microplates Supported            96-well and 384-well standard microplates

Handling Format                      Portrait

Plate Storage Areas                2 removable stacks (extra stacks are available)

                                               5 removable stacks for High Capacity Stacker.

Spill Control                             Interior components protected from accidental spillage by spill      shield rim located beneath rotating arm base

Weight                                     32lbs. (14.53 kg)

                                               High Capacity Stacker: 57 lbs. (25.85 kg)

Home Position                         Optical sensors for rotary and vertical arm home positions

Plate Sensor                           Mechanical pushbutton sensor

ArrayScan II System Lamp Unit

Input                                         90-115VAC/180-250VAC: automatic setting

Voltage/Frequency

                                               47-63 Hz, single phase

Current                                    8 ± 0.5A

Fuses                                      Voltage                           Specifications                          Quantity

                                               90-115V/180-250 V        250V, 5A, Delay Type (T)               1

Lamp Module                           Mercury Xenon Lamp

                                               Power Consumption approx. 200W

Lamp Module Life                    1500 hours (typical)

UV Visible Output                    350-700nm

Warm Up                                 7 minutes (typical)

ArrayScan II System Computer

Computer                                Pentium III Workstation, Ethemet 10/100 compatible

Operating System                   Microsoft Windows NT 4.0, Service Pack 5

Memory                                   512MB RAM

Hard Disk                                Two drives: (1) 9 GB and (1) 36GB for user data storage

Monitor                                     17" high resolution monitor

Printer                                      Color inkjet printer

Drives                                      CD read-write drive

Modem                                    56K external modem

ArrayScan II System

Environmental

Installation category                Class II

Pollution Degree                      Class II

Maximum Sound Pressure     <80dB

Level

Operating Temperature          59° to 104°F (15° to 40°C)

Operating Humidity                 0 to 85%, non-condensing

Storage Temperature              41° to 149°F (5° to 65°C)

Physical

Size (H x W x D)                     Space Required for Entire System:   32 in. x 60 in. x 40 in. (.8mx1.5mx1.0m)

Weight                                     Approx. 354lb. (161 kg) including weight of Stacker

Electrical

Grounding                                Through the power cord