SFC / SFE

Büchi Reveleris X2 Flash Chromatography SystemBüch

€26,999.00
Excl. 19% VAT , excl. Shipping Cost
€32,128.81 incl. Vat
ID-number: 60013
Status: LabprocureLabprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.?
Shipping: 4-6 weeks
Description:
Description:. The Reveleris X2 Flash Chromatography System is designed for the rapid preparation of complex samples using liquid chromatography. A flash chromatography separation uses a cartridge with a stationary phase such as 40-63µm silicon and a mobile phase such as hexane:ethyl acetate (70:30) at a flow rate of 40mL/min under moderate pressure (typically less than 100 psig). Although the resolution of flash chromatography is lower than that of analytical or preparative high performance liquid chromatography (HPLC), which uses 2-5µm particles, the method is extremely useful because it gives the analyzer the ability to separate gram-sized samples in a short period of time. In flash chromatography, as in analytical or preparative HPLC, separation depends on the relative interaction of the various compounds in the sample with the stationary and mobile phases. Compounds that interact more strongly with the stationary phase than with the mobile phase are more strongly retained by the column and have a longer residence time (and vice versa). Reveleris X2 Flash Chromatography Systems include a UV detector that can monitor three wavelengths simultaneously and an evaporative light scattering detector (ELSD). The ELSD allows all non-volatile compounds in the mobile phase to be monitored and compounds that do not absorb UV radiation to be detected. Operating Mode: Gradient Flash Chromatography System. Solvent Delivery System: 4 independent channels. Gradient Formation: Binary Gradient with High Pressure Mixing. Flow Rate: 1-200mL/min. Flow Accuracy: ± 3% (4-200mL/min). Maximum Pressure: 200psig. Gradient Accuracy (at 40mL/min): ± 1.5%. Gradient Precision (at 40mL/min): < 1%. Sample Modes: Liquid or Solid Sample Modes. Sample loader: Sample loaders for 3g, 25g and 60g can be used. Sample loader flask: Three sizes (15mL, 75mL and 150mL). Absorption detector wavelength range 200 – 500 nm. Number of wavelengths monitored: 3 wavelengths can be monitored and used to trigger fraction collection. ELSD detector Light source: Laser (0.3mW). Detector element: Silicon photodiode. Fraction collection trigger: UV signal, ELSD signal. Collection racks: Multi-position racks for 36x 25 mm tubes
Add to Offer List
More Information
Objektnummer AA00060013
ID-number 60013
Object name Büchi Reveleris X2 Flash Chromatography SystemBüch
Status Labprocure Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.
Manufacture Buchi
Shipping 4-6 weeks

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Product group: SFC / SFE

We can't find products matching the selection.
Back to Top
part-of-labexchange-group
Search engine powered by ElasticSuite
Smart Deals Smart Deals
Labprocure