Bohlin CVO 50
Objektnummer | B00013782 |
---|---|
ID-number | 013782 |
Object name | Bohlin CVO 50 |
Status | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
manufacturer: Bohlin
model: CVO 50
The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.
CVO
Rheological instruments backed with rheological experience
A practical rheometersystem in your laboratory.Whether your needs are for high use, busy Quality Control or for bespoke user-defined measurement procedures, the BohlinCVO is an instrument you can rely on. Compact and spill resistant with a membrane keypad the CVOÂsdesigned for easy set up and control. The CVO accepts interchangeable temperature control units and the options for extended shear rate and quantitative normal force arealso available.
Complete rheology
- Integrated, computer controlled systems
optimisessensitivity and minimisescabling and inter-connections
- Automatic gap zeroing and adjustment
withan integrated axial force sensor and precision stepper motor to control the gap precisely, easily and reproducibly
- Thermal mode
automaticallycompensates for expansion during temperature sweeps and ensures that the gap remains constant
- Axial force mode
allowsa pre-programmed normal force to be applied to the test sample (available with normal force option)
- Sample loading
iscontrolled using programmable descent rate to limit normal stresses imposed on the sample
- Unique air bearings
robust, porous design which is completely impervious to particle contamination. These bearings offer low inertia for oscillation data, low drag for viscometrydata and negligible rotational torque errors
- Wide torque range and measurement
accuratelyachieved because the motor design delivers a linear torque response over decades without drift. Low motor inertia and drive circuitry offer rapid transient response and wide operating frequency range
- Microstrainposition sensing
witha digital resolution of 107 parts per revolution and no signal drift to enable analysis of even weakly structured materials within their linear response region
- Broad speed range
withhigh resolution position sensing to ensure excellent performance across the entire speed range
Applications
- Coatings
- Adhesives
- Cosmetics
- Personal care products
- Foods
- Composites
- Petrochemicals
- Polymers
- Pharmaceuticals
- Asphalt
Software to make it happen
WindowsTMcompatible software is provided with every BohlinCVO delivering the ease of use and user-defined flexibility professionals around the world have come to expect.
Viscometrymodemeasures viscosity as a function of shear stress or shear rate. Measurements include single value of shear rate (or stress), table of shear rates (or stresses), continuous shear rate (or stress) ramp (including yield stress) and complex shear rate (or stress) profile. Temperature control can be isothermal (time sweep), or follow defined gradients or step changes.
Creep modemeasures the creep compliance and recoverable compliance as function of time. User defined sampling modes can be set. Zero shear viscosity and yield stress can be determined.
Oscillation modemeasure the dynamic viscoelasticproperties as a function of frequency, Measurements include single frequency, frequency sweep, amplitude sweep, time sweep and temperature sweep (gradient, step change or profile). Tests can be performed at constant stress or constant strain amplitude using Auto-stress mode.
With options
Almost all rheological measurements require accurate temperature measurement and control. The CVO accepts a variety of temperature control units, which are easily interchangeable, to cover all applications. By virtue of the mounting system used, space and access for sample loading and trimming are not compromised when changing the temperature control system. Available units include a range of fluids circulators, Peltierdevices (plate and cylinders), electrically heated plates and a forced gas oven with a liquid nitrogen cooling option. Bohlintemperature control units are fully controlled by the software and the instrument detects which type of units is installed considerably simplifying installation.
Overview
Torque range
0.5μNm to 100mNm
Torque resolution
1nNm
Position resolution
0.9μrad
Frequency range
10μHz to 100Hz
Controlled speed range (CR mode)
50mrad s-1to 320rad s-1
Measurable speed range (CS mode)
0.1μrad s-1to 320rad s-1
Normal force N1 measurement range*
0.001N to 20N
Temperature range (dependent on control used)
-150°C to 550°C*
-40°C to 450°C
Temperature controls
Fluids Circulator
-40°C to 250°C
ETO (Extended Temperature Option)
-15°C to 300°C
Melts Oven
ambientto 450°C
PeltierPlate
-30°C to 200°C
PeltierCylinder
-20°C to 180°C
Universal PeltierOption  Coaxial Cylinder or Cone/Plate Geometries
ETC (Extended Temperature Cell)
ambientto 550°C*
ETC with optional LTU (Low Temperature Unit)
-150°C to 550°C*
*available if NormalForce option is fitted
Nominal operating voltage
110 or 220V
Size (with Peltierplate)
52cm (H) x 29cm (W) x 34cm (D)
Weight (with Peltierplate)
27kg