Bischoff 2250
Objektnummer | B00014738 |
---|---|
ID-number | 014738 |
Object name | Bischoff 2250 |
Status | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
model : HPLC 2250
annotation : Dokumente engl.
The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.
HPLC Pump 2250
Model 2250 The serial dual piston pump for routine and research
Technical requirements and design
Current users of modern HPLC pumps expect to obtain not only minimum pulsation and a solvent independent flow reporducibility, but also an optimum performance over the largest possible ranges of flow and pressure combined with a high resistance against salt solutions in the pump head. Operation should be possible eihter in stand-alone mode or via a computer or a central processor.
A user-oriented design should allow easy handling and maintenance.
The model 2250 HPLC Compact Pump, manufactured under ISO 9001 satisfies all these requirements and is therefore suitable for use in both simple isocratic and gradient HPLC systems:
- The serail dual piston pump with only two check valves gurantees a minimum rest pulsation. The use of an additional pulse damper is generally not necessary even when using pulsationsensitive detectors such as Refractiv Index detector or Electrochemical detector.
- Easily interchangeable pump heads cover a wide linear range of flow rates and allow operation with microbore, analytical, preparative and short columns for fast HPLC. Three different pump heads can be used for various application areas.
Electronic pump head identification with automatic control of flow and pressure ranges simplifies the use of the pump for the different applications.
Typical flow ranges are:
Micro pump head
Flow range: 1 999 µL/min
Analytical pump head
Flow range: 10 4999 µL/min
Preparative pump head
Flow range: 1.0 19.99 mL/min
The pump head includes the complete liquid delivery unit and it easily accessible for maintenance. Due to the serial arrangement of pistons and the use of only two check valves the model 2250 HPLC Compact Pump combines the advantages of a single piston pump with those of a dual piston pump.
For applications with buffers the pump head can be provided with a piston back wash assembly. Rinsing of high pressure piston seals prevents a possible crystallisation of buffer salts which might penetrate behind the seals through existing micro leakages, thereby causing damage to the seals. Thus, a wet or humid space behind the seal can prevent crystallisation.
Various check valve cartridges are available for different applications and for the analytical, microbore and preparative flow range.
Service and Maintenance
The model 2250 HPLC compact Pump can be used for high pressure or low pressure gradients. To run a high pressure gradient you need one additional model 2250 HPLC Compact Pump and the model 1152 Central Processor for gradient control. In low pressure mode there is only the need for the model 1152 Central Processor and the model 1150 Low Pressure Gradientmixer which is available for binary or ternary gradients. Programming of both kinds of gradient modes is the same, there is no need to learn different program structures.
The compact design simplifies maintenance because parts like the pump head are easily accessible. The pump can be upgraded to the latest software version by simply interchanging an EPROM an the main board inside the pump.
EPROMs for special applications, such as for slow start-up flow program for colum protection are also available.
Specifications
Flow rate range Pump head M 0.001 0.999 mL/min
Pump head A 0.01 4.99 mL/min
Pump head P 0.1 19.9 mL/min
Flow rate accuracy at 20 80 % FS ≤ 3 %
Flow reproducibility ≤ 0 ,5 %
Pressure range Pump head M 0 60 Mpa
Pump head A 0 50 Mpa
Pump head P 0 15 Mpa
Pump head volumes (analytical)
- main piston 54 µL
- priming piston 20 µL
Pump displacement volumes
- main piston 45 µL
- priming piston 14 µL
Length of stroke
- main piston 5.6 mm
- priming piston 1.8 mm
Residual pressure pulsation compensated by setting the proper ≤ 3 %
at 2 mL/min and 20 Mpa into a 125 compressibility
mm column
Pressure measurement a) volume of the pressure transducer 50 µL
b) accuracy 3 %
c) resolution of the display 0.1 Mpa
d) recorder output 1 mV/Mpa
Pressure shut down adjustable
a) maximum switch-off time 0 to FS ≤ 20 ms
b) minimum switch-off time 0.1 to FS
alter initial delay of 2 min 3 cycles
not effective at 0.0 Mpa
Compressibility adjustable
Correction mode manually
Purge valve standard
Purge key runs maximum flow of installed head
Display alternatively a) flow 6 digit LED display
b) pressure with sign and pump
head type other
c) compressibility than standard
Pump head identification automatically
Input by 6 push button keys
Exteranl control by contact closures a) stop pump
Or active input b) reduce flow
By RS 232 or current loop all functions
Auxiliary outputs a) suction phase
b) pump stop
Power requirements 110/220 V ± 10 %
50/60 Hz
50 VA
Temperature range + 15 °C up to +30°C
Dimensions 381 x 255 x 133 mm
Weight 8.7 kg
Lambda 1010 UV/VIS Detektor
Simple operation conditions and compact desing
The
spectromonitor Lambda 1010 is a programmable UV/VIS detector for HPLC and CE. The advanced technology and the user friendly design of the instrument generate superb results in routine and more sophisticated chromatographic applications.
Economical on lab space
The spectromonitor Lambda 1010 is especially designed to save lab space. All components are selected under the highest quality standards and specifications to meet the demand for modern HPLC, LC an CE separation technologies. The high specifications and ease of use of the Lambda 1010 make it easy to use for a wide variety of applications.
Sophisticated optics
The design of the optical block enables the user to have access to all important parts (e.g. flow cell, lamp) without disturbing the stability of the spectromonitor Lambda 1010. The combination of low power electronics (low rise in temperature) and the compact and robust optical bench result in a remarkably compact instrument. The optical system is mounted on a separate base plate which is integrated into the housing. The lamp holder and the holder for the flow cell are outside the housing of the spectromonitor Lambda 1010. Therefore the interchange of flow cells of lamps is very easy.
The flow cells are reproducibly fixed by two knurled screws. The lamps are prealigned and can be mounted without any further alignment. The light beam of the Deuterium lamp is focussed by a high quality quartz lens in the lamp holder on the entrance slit of the monochromator. The grating is moved with a DC-servo system, wavelength is measured by a high linearity potentiometer. To ensure the highest stability of the base line, the light beam leaving the monochromator passes through a beam splitter and 15% of the light is used to provide the stable reference signal.
Applications
The spectromonitor Lambda 1010 allows continuous variation in wavelength from 190 - 800 nm and in the range from 0.001 - 1.999 AUFS. Including the excellent values for stability and signal-to-noise ratio you will see effective detection even with the lowest sample concentrations.
Wavelength switching
For analyses of compounds which differ in their l max. and/or in concentration and therefore in the absorbance at the peak maximum, it is useful to switch the detection wavelength and the range during the chromatographic run according to the retention time of the compound. For complex mixtures the spectromonitor Lambda 1010 offers switching of l and range with up to 9 steps per program.
Detection at the absorbance maximum
To detect unknown compounds at their maximum absorbance, it is recommended to use the l max. wavelength . The spectromonitor Lambda 1010 offers the possibility to measure the UV-spectra of eluting peaks during the chromatogram withourt stop-flow. Measuring first the absorbance of the eluent and then the spectra of the separated compounds you will obtain the peak spectra by a subtraction process.
Spectra
With the spectromonitor Lambda 1010 you have the ability to measure a spectrum while the chromatogram is running. For this purpose a Rheodyne valve is used (e.g. RH7125) as a stream switching device. Instead of the sample loop, the inlet and outlet capillaries of the flow cell are connected to the valve. At the position Inject, the eluent is flowing through the valve and the flow cell continuously. At the peak maximum the valve is switched onto the position Load. The compound of interest is stopped in the flow cell for spectral measurement. During spectral measurement the eluent is still flowing through the column and the equilibrium is not disturbed.
Baseline subtraction
Gradient elutions often shows a base line drift, due to self absorbance of the eluent related to the wavelength. This effect is significant in the lower UV range. The spectromonitor Lambda 1010 allows you to memorize the baseline of the blank-gradient run and therefore to subtract it from the sample gradient run. As a result you get an increase in sensitivity and the identification of small chromatographic signals.
Technology for today and tomorrow
Capillary chromatography, CZE and CE
The easy access to the cell block in the spectromonitor Lambda 1010 enables other special facilities. The regular micro flow cell with a volume of 0.8 µl is useful for columns with an internal diameter of 1 to 2 mm and a length of 12.5 to 25 cm. For capillary chromatography (µLC) it is recommended to decrease the cell volume and the void volume between column and flow cell. Chromatography with columns with internal diameters of 3 to 4 mm and detection in a micro flow cell becomes more and more important.
·
Less eluent consumption for columns with smaller internal diameter for economic and ecological benefits.
·
Less sample amount is needed reflecting current practice in many laboratories.
Using capillary columns, there is the need to detect the eluent directly on-column to avoid peakbroadening and any other extra column effect. This is possible with the capillary flow cell of the spectromonitor Lambda 1010 where the fused silica separation capillary is mounted in the light beam. The capillary flow cell for the spectromonitor Lambda 1010 is retrofitable. An additional calibration of the detector to adapt the flow cell is not needed. The self aligning optics of the capillary flow cell
guarantee
the adjustment of different capillary diameters to the optics of the detector.
Due to the small illuminated volume, the low noise of ±2x10-5 AU, and the high separation efficiency of CZE, the mass-sensitivity for Uracil is approx. 1 pg. The capillary acts like a cylindrical lens and gives extraordinarily good linearitiy for the detector with absorbances < 0
,1
AUFS.
Specifications
Wavelength range
190 - 800 nm
with Deuterium lamp (standard)
190 - 400 nm
with Halogen lamp (optional)
400 - 800 nm
Optical band width 6 nm
Wavelength accuracy ±2 nm
Wavelength reproducibility ±0.2 nm
Sensitivity range
incremental in 0.001 AU steps 0.001 - 1.999 AU
Noise at 230 nm
(Cell filled with water) ±1 x 10 -5 AU
Baselinedrift at constant temperature
at 230 nm
5 x 10
-4
AU/h
Auto zero range -0.1 up to +1.999 AU
Time constant 0.02 s / 0.1 s / 0.5 s / 2 s
Recorder output 100 mV
Integrator output 1 V/AU
Marker
internal +10 mV
external +5 mV
Flow cells , optical pathlength
analytical , 10 mm (Standard) 10 µl
micro , 3 mm (optional) 0,8 µl
preparative , 0.3 mm (optional) 2 µl
capillary , 75 µm (optional)
Pressure limit of the cell 5 MPa
Programming
Conditions per line
Start time of the line 1-9999s
Wavelength 190-400 nm
400-800 nm (optional)
0,001 1.999 AU
Rage at start of program line
Auto zero by reference run
Baseline correction over time
Recording spectra
Range 0.05 1.999 AU
Wavelength range 190-400 nm
400- 800 nm (optional)
Baseline correction over wavelength by revernece run
External control
- by contact closures autozero
Marker
- by current loop or via RS232 all functions
Temperature range + 15 up to 30°C
Power requirements 110/220 V ± 10%
50/60 Hz
55 VA
Dimensions 483 x 255 x 155 mm
Weight 13 ,9 kg
Multiwavelength Detector DAD-3L
The DAD 3L is manufactured under ISO 9001. Its features offer great benefits not only for routine but also for research and preparative applications
:
Three wavelength channels
The instrument allows the independent selection of 3 wavelength channels between 190 and 395 nm. The signals of these channels are available simultaneously with a settable frequency between 0.2 and 20 Hz.
Diode array technology allows high sensitivity combined with highest baseline stability
The detector uses the diode bunching technique to increase signal to noise ratio. This means for each channel an independent selectable number of up to 60 diodes can be bunched to improve the signal to noise ratio.
Internal reference channel
Beside the 3 signal channels a reference channel can be defined to eliminate lamp energy instabilities, which may occur with instable current input. The diode bunching option is also available for the reference channel.
Ratio channel (ch1/ch2) for peak purity check in real time
The
ratio between channel 1 and channel 2 which is calculated by the detector itself is a available as continuous signal on a separate channel. Data are provided with the same frequency as in the other channels.
Analogue integrator and recorder output for all signal channels
All 3 signal channels and the ratio channel have separate analogue integrator (1 V/ 1 AU) and recorder outputs (100 mV).
Recorder output range is
free
selectable between 1 mAU and 2000 mAU.
Stand alone Detector for any HPLC system
To integrate the detector into an existing HPLC-system a marker port with in- and output option (5 mV / 10mV) and an input for the auto zero via contact closure is available.
RS 232 interface for full access to all parameters
The 9 Pin RS232 port allows a full remote control and data transfer via PC. This interface is also used when the instrument is integrated in a BISCHOFF HPLC - System. To write own control software the Syntax for all commands is documented in the manual.
Upgrade to full Diode Array Detector is possible
Easy lamp replacement
The Bischoff Deuterium lamps come pre-aligned. The
combination with the special lamp holder make
lamp changes very easy. There is no need for tools.
Flow cells for different applications
Analytical flow cell 10 mm path length
8 µL cell volume
Preparative flow cell 0.4 mm path length
2 µl cell volume
SPECIFICATIONS Multiwavelength Detektor DAD-3L
Number of diodes: 256
Optical bandwidth: 4 nm
Pixel distance: 0 ,8 nm
Wavelength accuracy: + 1 nm
Wavelength
Reproducibility: + 1 nm
Baseline noise at 230 nm: + 0.00002 AU
( cell filled with water)
Measuring range: 0.001 1.999 AU/FS
( incremental in 0.001 AU steps)
Drift compensation: By selectable reference channel
Auto zero range: -0.001 1.999 AU
4Recorder outputs: 0 1.00 mV
4 Integrator outputs : 0 1 V/AU
Analytical flow cell Optical Path : 10 mm
Volume: 8 µl
Preparative flow cell Optical path: 0.4 mm
Volume: 2 µl
Pressure limit of the cell: 5 MPa (=50 bar)
Lamp : Deuterium lamp with elapsed time indicator.
Characteristic life time ia 1000 hours.
Input by 8 push button keys.
External control:
By contact closures: auto zero
Marker
Via RS 232 all functions
Power requirements: 110/220 V ± 10%
50/60 Hz
55 VA
Temperature range: +15°C up to +30 °C
Size :Optical Unit Electronical Unit
DAD 3L-OU DAD 3L-EU
Height : 155 mm 130 mm
Width : 260 mm 260 mm
Length : 480 mm 400 mm
Weight : 12 ,8 kg 4,0 kg