Biotek ELx50
Objektnummer | B00019319 |
---|---|
ID-number | 019319 |
Object name | Biotek ELx50 |
Status | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
manufacturer : Biotek
model : ELx50
annotation : Dokumente engl .
The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.
ELx50 Microplate Strip Washer
Overview
BioTek's years of experience in the development of both microplate washers and automated systems for EIA applications has culminated in the ELx50TM Strip Washer. As a self contained and programmable instrument, the ELx50 allows for full control of precise fluidic delivery from the gentle dripping of a simple squeeze bottle to the full force of pressure delivery systems.
The new ELx50 Washer is now a truly flexible platform that provides washing capabilities unsurpassed in its class. Newly available models with biomagnetic separation and vacuum filtration capabilities make the ELx50 an excellent choice for automating the wash steps of 96-well magnetic or polystyrene bead assays, such as those developed on the Luminex®
xMAP® technology platform. The ELx50 Washer is Luminex® xMAP® approved. Users not requiring an integrated stacker can expect the same great bead washing performance as BioTeks industry leading full plate washers but here in a more compact footprint. Comprehensive onboard software makes programming quick and easy. Custom magnets, in either flat or ring designs, incorporate high-energy neodymium iron boron magnets for rapid separation of micrometer and nanometer magnetic beads with superior retention. A fast and efficient vacuum filtration module allows vacuum to be adjusted with a range of settings for flexibility with polystyrene beads when using various filter pore sizes and sample viscosities. The vacuum filtration module is also well suited for filtration-to-waste processes such as PCR cleanup after DNA amplification to remove unwanted residues or reaction by-products with filtrate. The washers modular platform allows for processing standard solid bottom plates used in a laboratorys many traditional ELISAs and cell based assays.
The ELx50 can also be equipped with our patented Dual-Action TM 16-channel manifold. This breakthrough design allows for independent control of the dispense and aspiration manifolds for overfill washing and overflow protection in both 96- and 384-well formats. The problem of fitting dispense and aspirate tubes into a much smaller 384-well is solved with the ELx50. Additionally, in a 96-well format, the Dual-Action manifold provides incomparable wash performance with two sets of dispense and aspiration tubes per well. This exclusive method of two-fold aspiration guarantees low residuals.
As a welcome upgrade from manual processing, the new ELx50 Microplate Strip Washer will bring to your lab an all inclusive wash solution offering consistent performance and unattended operation.
High Strength Biomagnetic Separation
The ELx50's custom magnet designs incorporate high-energy neodymium iron boron magnets for rapid separation of micrometer and nanometer beads with superior retention.
Fast and Efficient Vacuum Filtration
An available vacuum filtration module automates the washing of 96-well filter bottom plates. Vacuum is adjusted via a range of settings for optimal performance with various filter pore sizes.
Automated Liquid Level Sensing
The Liquid Level Alert TM option allows users the convenience of continuous monitoring for both supply and waste bottles. At the beginning and end of a wash protocol, the liquid level is verified to ensure sufficient wash buffer remains in the designated dispense bottle to complete a microplate wash. Sufficient storage capacity in the waste bottle is also verified.
Patented Dual-ActionTM Manifold
The ELx50/16 offers incomparable wash results for 96- and 384-well microplates. In 96-well format, the unique design incorporates two sets of dispense and aspiration tubes per well.
Features
General
- Syringe drive fluid delivery system for precise control over all fluid flow rates
- Wash single strips or full plates
- 96- and 384-well microplates
- Unique priming trough built into removable microplate carrier for effortless priming and easy maintenance
- Automatic buffer switching
- Create, edit, delete and copy up to 75 programs from the keypad
- Link up to 10 programs to run the most complex routines
- Multi-user friendly; total programming control for complex research applications, yet easy to use for routine clinical work
- Programmable shaking duration and intensity
- Built-in maintenance programs
- Bottom washing and crosswise aspiration protocols
- Small footprint with integrated dispense and waste pumps
- Aerosol cover for safety
Biomagnetic Separation
- High strength biomagnetic separation for super paramagnetic bead based assays, such as Luminex xMAP®
- High energy neodymium iron boron magnets
- Optimized field gradients within wells
- Choice of flat or ring magnets - two 96-well high strength designs custom for BioTek microplate washers
- Rapid separation of micrometer and nanometer beads
- Superior microsphere retention
Vacuum Filtration
- Fast and efficient vacuum filtration for polystyrene bead assays or filtration-to-waste processes
- Range in accommodated filter pore sizes from 0.45 mm to 1.2 µmm
- Selectable vacuum levels from 91 mmHg to 313 mmHg for varying sample viscosities
- Carrier vacuum grate directs liquid droplets away from plate for minimized after-wash residual on plates underside and no cross contamination
- Software programmable dispense volume, soak and aspiration time for completely unattended operation and recall
Models
Model Part # 96-well 96-/384- Buffer Biomagnetic Vacuum
only well Switching Separation Filtration
---------------------------------------------------------------------------------------------------------------------------
ELX50/8
ELX50/8M
ELX50/8MF
ELX50/8F
ELx50 TM ELX50/8V
ELX50/12
ELX50/12V
ELX50/16
ELX50/16V
Specifications
General
Assays
Magnetic bead, polystyrene bead (model dependent)
- Multiplex assays
- Bead-based ELISA
ELISA
Cell-based assays
Protein arrays
Filtration-to-waste processes (model dependent)
Separation
Biomagnetic separation, vacuum filtration (model dependent)
Microplate Types
96- and 384-well (model dependent)
Standard height and low profile
Solid and filter bottom (model dependent)
- Filter pore sizes 0.45 µM to 1.2 µM
Shaking
Programmable in minutes and seconds up to 60 minutes
Intensities - slow, medium, fast or variable
Soak Time
Programmable in minutes and seconds up to 60 minutes
Magnet
High strength 96-well format
Choice of two designs, custom for BioTek microplate washers:
- Flat
- Flat-bottom well - beads pulled to band across well bottom
- Round-bottom well - beads pulled to button at well bottom
- Ring - beads pulled to 4-zone ring at well bottom
Incorporated into carrier, removable for non-magnetic washing
Safety/Convenience/Maintenance
Waste sensing, fluid detection (optional)
Aerosol cover
Overflow protection
Pre-programmed maintenance routines
Onboard Software
2 x 24 character LCD display
25 alphanumeric soft keys
Create, edit or run multiple protocols
Operating Temperature
15°C to 40°C (59° to 104° F)
Humidity
10% to 85%, non-condensing
Electrical
Compatible with 100 to 240 V~ ± 10% @ 50-60 Hz
Washing
Manifold Type
96-well washing: 8-tube (1x8) manifold
12-tube (1x12) manifold 96-/384-well washing :
Dual-Action TM 16-tube (1 x 16) manifold
Washing Speed
Solid bottom plates 3 asp ./ disp . cycles: >300 µL/well, 96 wells, 8-tube manifold, final
aspirate : < 130 seconds
Filter bottom plates: Variable, based on wash parameters
Fluid Delivery
Internal positive displacement syringe drive
Vacuum Filtration
Selectable vacuum levels (final at 30 seconds):
0.45 µm 96-well plates: Low: -91 mmHg
Medium: -150 mmHg
High: -313 mmHg
1.2 µm 96-well plates: Low: -95 mmHg
Medium: -155 mmHg
High: -299 mmHg
Vacuum filtration time range: 1 to 180 seconds
25 - 3,000 µL/well (model dependent)
Selectable in 1 µL increments
Buffer Selection
Automatic switching for up to 3 wash buffers (model dependent)
Flow Rates
1-9
Wash Cycles
1-10
Dispense Precision
≤3% CV
Residual Volume
Solid bottom plates ≤2 µL/well
Filter bottom plates Average increase weight of plate ≤1.2 g after dispensing 300 µL
to 0.45 µm plate, filtration 30 seconds, low vacuum, blotted
Sterilization
Chemical: 70% ethyl or isopropyl alcohol and 0.5% sodium hypochlorite solution
Supply Bottle Volume
2 L
Physical Characteristics
Dimensions
14"W x 16"D x 6.5"H (35.6 x 40.6 x 16.5 cm)
Weight
22 lbs (9.8 kg)
Regulatory
Regulatory