Biotage PSQ 96
Objektnummer | B00013745 |
---|---|
ID-number | 013745 |
Object name | Biotage PSQ 96 |
Status | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
manufacturer : Biotage
model : PSQ 96MA
annotation : Dokumente engl.
The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.
Meets the diverse genetic determination needs of clinical research laboratories :
Assays successfully developed for any genetic marker
Built-in quality control (QC) confirms genotyping results
Quick, simple and convenient to use
PSQTM96MA System is a multi-application genetic analysis solution designed to meet the diverse needs of clinical research. The versatile system combines SNP and mutation analysis with quantification capabilities and the sequencing of short stretches of DNA to provide a complete genetic research solution.
The system uses proven Pyrosequencing technology to enable real-time, accurate genetic determination.
PSQ 96MA System comes with dedicated software. The complete platform also includes the Vacuum Prep Workstation for post-PCR sample preparation, optimized reagent kits and the Pyrosequencing Assay Design Service and Software.
Benefits of using Pyrosequencing and PSQ 96MA System
Assays successfully developed for any genetic marker
An unbeatable track record : a functional assay for any genetic marker (insertion, deletion, mutation, SNP or multiple polymorphism).
Simple and flexible assay design with minimal limitations in primer placement.
Multiple polymorphisms in close proximity are easily analyzed.
Suitable for rapidly mutating organisms new mutations can be detected.
Quantitative data expands investigation options.
Built-in quality control (QC) confirms genotyping results
Pyrosequencing results (a PyrogramTM) present the sequence context surrounding the genetic variation.
Every sample contains its own confirmation of validity. No need for external controls.
QC based on the gold standard : DNA sequencing the best confirmation there is.
Quick, simple and convenient to use
Easy to manage system within a multi-user environment.
Short learning curve the PSQ 96MA System is up and running in one day with minimal training.
Convenient 96-well format.
Real-time results.
Versatile system
One complete solution to perform many different kinds of analyses see table 1 for examples.
Flexible run setup analyze one assay with up to 96 individual samples or up to 96 different assays in one plate
Versatility of the PSQ 96MA System
PSQ 96 MA System capabilities Clinical research application examples
SNP and mutation analysis SNP association studies
SNP and mutation genotyping
Sub-tubing of microbes
Quantification CpG Methylation analysis
SNP pooling studies
Allele frequency quantification
Gene copy number
Loss of heterozygosity
Sequence analysis of short stretches of DNA Bacterial identification
Fungal identification
Antibiotic resistance analysis
Sequence siganture
Technical overview
The PSQ 96MA System consists of an automated instrument, with dedicated software for system control and data analysis, as well as optimized reagent kits, consumables and sample preparation tools. The system analyzes 96 samples simultaneously, in a 96-well plate format, using the robust and reliable chemistry of Pyrosequencing technology. This eliminates the need for gels, dyes or specific labels.
Pyrosequencing technology uses an enzyme-cascade system, consisting of four enzymes and specific substrates, to produce light whenever a nucleotide forms a base pair with the complementary base in a DNA template strand. This light signal is detected, the base registered and the next nucleotide added. If the added nucleotide is not complementary to the next base in the template, no light will be generated.
The PSQ 96MA System detects and transforms the light into signals, which are displayed as peaks in the resulting Pyrogram. The height of the signal is proportional to the number of bases incorporated, resulting in quantitative data.
Technical data and requirements
Input voltages 110-120, 220-240 V
Power consumption Maximum 280 VA
Ambient temperature range 18-28°C
Ambient humidity 30-90% relative humidity
Dimensions (HxWxD) 490 x 520 x 650 mm
Clearance space (HxWxD) 800 x 520 x 700 mm
Weight 52 kg
Instrument temperature range From room temperature up to 50°C
Instrument temperature accuracy ±1°C
Process time, 96 samples SNP analysis: ≥10 minutes
(9 dispensations/well)
Sequence analysis: ≥35 minutes
(30 dispensations/well)
Minimum computer requirements for an office installation.
Operating system WindowsTM 2000 or XP, English version
Processor Intel Pentium III, 450 MHz
RAM 256 MB
Free hard disk space 20 GB
CD-ROM 4x
Graphics card Super VGA
Monitor SVGA 1152 x 864 pixels, 256 colors
Pointer device Mouse or similar