Bioscience Konelab 20i

ID-number: 014463
Status: Archived Product?The unit is no longer available.
Shipping:
Description:
Bioscience Clinical-chemical Analyser Konelab 20i.
siehe Storeview
More Information
Objektnummer B00014463
ID-number 014463
Object name Bioscience Konelab 20i
Status Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

 

Manufacturer:  Thermo Scientific

Model:              Konelab 20

 

 

The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.

 


Technical specifications:

Throughput

Workload dependent, Typical normal operation up to 200 tests / hour. Time to the first result typically 3 to 12 minutes.

 

rehearse

Continuous access to the samples without interrupting the analysis operation possible.

Max. Load capacity:

84 routine and 5 emergency samples in 6 segments of 14 positions per segment. With barcode reader and vascular detection.

Sample cups of 0.5 and 2.0 ml, tubes of 5 and 7 ml, tubes of 10 ml with suitable segments.

Sample types: serum, plasma, urine, CSF.

Sample Volumes: Allowed 1-120 μl; Typically 2-15 μl and 50 μl for Na +, K + and CI - ISE tests.

 

reagents

Constant access to the reagents is possible without interrupting the analysis operation. Detection by external barcode reader. Reagent status is clearly displayed in real-time. Up to four pipetting steps per test possible.

Storage in the system:

35 positions in the cooled reagent plate.

Reagent tubes: 10, 20 and 60 ml

Reagent volumes: 2-250 μl; Typically 120-200 μl.

 

cuvettes

Discrete disposable multicell cuvette with 12 cells. Constant access to the cuvettes is possible without interrupting the analytical operation.

Loading capacity:

600 measuring cells in 50 multicell cuvettes with 12 reaction cells; Typical walk-away time up to 3 hours.

 

calibration

Linear, non-linear or blank calibration. Depending on the test procedure, use either of a single calibrator or automatic dilution series of a primary standard. Automatic repetition possible for blank value correction.

 

quality control

Real-time quality control according to various Westgard custom rules. Programmable control intervals. Graphical preparation and printout of QK data, daily and cumulative reports.

 

Pipetting samples and reagents

Single needle principle with flow purge, external cleaning and liquid sensors. Pipetting with precision injection, drive by micro step motor.

Final volumes: 100-250 μl.

Reproducibility VK below 2%

Sample volume> 2 μl and reagent volume> 5 μl

 

Photometric measurement

One-channel filter photometer with beamsplitter reference. -11 fixed filters, others available upon request.

Spectral range: 340-800 nm.

Measuring temperature: 37 ° C.

Measuring principles: colorimetry, turbidimetry.

Types of measurement: kinetic, end point.

Kinetic measurements: 30 sec 60 min, max. 12 points.

Light source: halogen lamp with linear absorption range of 0-2.5 A, resolution of 0.001 A and reproducibility of SD <0.005 E at 2 E.

 

Product group: Clinical chemistry