BioRad Quickstep
Objektnummer | B00021952 |
---|---|
ID-number | 021952 |
Object name | BioRad Quickstep |
Status | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
model : QuickStep
annotation : Dokumente engl .
The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.
Technical Data
Environment and storage conditions
This equipment is designed to be safe at least under the following conditions (EN61010 - 1):
- indoor use;
- altitude up to 2000 m;
- temperature 5 °C to 40 °C;
- maximum relative humidity 80 % for temperatures up to 31 °C decreasing linearly to 50 % relative humidity at 40 °C;
- mains supply voltage fluctuations up to ±10 % of the nominal voltage;
- applicable rated pollution degree.
Operating temperature
The operating temperature is between 15 °C and 25 °C. Prefer air-conditioned rooms and instrument places protected from direct sun exposure.
Mains voltage and fuses
Analyzer
Voltage range: 110V~ to 230V~ ±10 %
Power requirement: max. 400 W
Frequency range: 50Hz to 60Hz
Mains fuse: 6,3AT
Computer, monitor and printer
For electrical details of the PC equipment please refer to the technical documentation of the OEM manufacturer.
Weights and dimensions of the Quick Step Biotest system
Analyzer with cover
Weight: 130kg
Dimensions: 114cm x 156cm x 100cm (W x D x H)
(Depth with waste bag and completely opened drawer)
Accessories
Weight: Approximate 84kg
For details of the PC equipment please refer to the technical documentation of the OEM manufacturer.
Photometer
Spectral range 400 - 700 nm
Dynamic range -0.100 to 3.000 OD (measurement range)
Accuracy ± 0.005 or 2.5% (whichever is greater)
Linearity 0 - 2.000 OD ±1%
Detection Photodiode
Reading time < 15 seconds
Filters Up to 8 positions
Values are achieved under optimal conditions and can vary depending on environmental conditions, instrument status and processing conditions!
Incubation
Capacity 4 independently controlled chambers
Temperature range Room temperature + 7 °C to 50 °C
Accuracy - 2 °C; + 0 °C (measured in plate, 100 µl aqua)
Uniformity - 1 ,5 °C; + 1 °C (measured in plate, 100 µl aqua)
Values are achieved under optimal conditions and can vary depending on environmental conditions, instrument status and processing conditions!
Washer
Capacity Max. 4 positions (including cleaning solution)
Wash head 1 x 8
Dispense volume 200-2500 µl/well
Precision ± 5% CV at 300 µl
Residual volume < 2.5 µl in U-shaped bottom
< 4 µl in flat bottom
Fluid alarms Reagent low, waste full
Features Sweep mode, soak, top & bottom wash, variable pump speed
Values are achieved under optimal conditions and can vary depending on environmental conditions, instrument status and processing conditions!
Dispenser
Pipettor Liquid pipettor for disposable tips
Liquid level detection Standard
Min.-Max. volumes 10 µl to 300 µl with 300 µl (small Eppendorf ) tips
301 µl to 1000 µl with 1100 µl (large Eppendorf ) tips
Accuracy < -15 % at 25 µl (aqua)
< - 5 % at 100 µl (aqua)
Precision < 5 % CV at 25 µl
< 2.5 % CV at 100 µl
Features Tip detection, mixing, multi-dispensing
Values are achieved under optimal conditions and can vary depending on environmental conditions, instrument status and processing conditions!