BioRad Mini Protean
Objektnummer | B00012639 |
---|---|
ID-number | 012639 |
Object name | BioRad Mini Protean |
Status | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representating the delivery volume. The exact delivery content you will find only in the offering text.
Introduction
The Mini-PROTEAN II dual slab cell allows rapid analysis of protein and nucleic acid samples in miniature polyacrylamide gels. The cell allows analysis to be completed two to three times faster than is possible with conventional 16 cm cells, while maintaining comparable resolution. The Mini-PROTEAN II cell 'can run two slab gels for analysis of up to 30 samples at one time.
The Mini-PROTEAN II cell makes casting and running miniature slab gels almost effortless. Glass plate sandwiches are assembled using the unique four-screw Clamp Assemblies, then transferred to the alignment bar of the separate casting stand. The clamp screws are loosened, the plates and spacers are aligned, the screws are re-tightened, and the glass plate sandwich assembly is snapped into one of the two casting slots of the casting stand in one simple motion. No grease or agarose plug is required for casting. Once the gels are cast, the clamp assemblies are snapped onto the inner cooling core, samples are loaded, and the electrophoretic run is complete within 45 minutes. While two gels (up to thirty samples) are being run in the Mini-FROTEAN II cell, two more may be cast in the separate casting stand.
Specifications Construction
Inner coollng core Molded polysulfone
Ciamp assemblies Glass-filled polysulfone clamps with acrylic pressure plate
Power buffer chamber, Iid, Molded polycarbonate
casting stand
Electrodes Platinum wire 0.254 mm diameter
Gaskets: coollng core, casting stand Silicone rubber
Combs Teflon®
Spacers Polyvinyl chloride (PVC)
Shipping weight 2.2 kg
Overall size 16 cm (L) x 12 cm (W) x 18 cm (H)
Gel size 7cm(L)x8cm(W)
Glass plate sizes (inner) 7.3 cm x 10.2 cm
(outer) 8.3 cm x 10.2 cm
Voltage Limit 600 VDC
Note: Mini-PROTEAN II cell components are not compatible with chlorinated hydrocarbons (e.g., chloroform), aromatic hydrocarbons (e.g., toluene, benzene), acetone, ethanol, or 2 amino-2 methyl-1, 3 propanediol. Use of such organic solvents voids all warranties. Cal! 1-800-4-BIORAD for technical information regarding chemical compatibility of Mini-PROTEAN II cell components with various laboratory reagents.
Teflon is a registered trademark of E. I. DuPont de Nemours and Co.
Description of Major Parts
Fig. 2.1. Mini-PROTEAN Ii siab cell, Iower buffer chamber, and lid (a), casting stand (b), inner cooling core (c), and sandwich clamp assemblies (d).
Sandwich Clamp Assemblies
Sandwich clamp assemblies consist of two clamps with two screws each, permanently attached to a clear acrylic pressure plate. A gel sandwich is formed by placing a long (outer) plate against the acrylic pressure plate, adding two spacers, and then a shorter (inner) plate to complete the sandwich.
The combination of the four clamp screws and the acrylic pressure plate assures even pressure over the entire length of the glass plates and spacers, providing a leak-proof seal while preventing plate damage due to uneven pressure.
Casting Stand
The casting stand is separate from the Mini-PROTEAN II cell so that two gels may be cast while two others are being run. The stand consists of one alignment bar and two casting slots. The glass plates and spacers of the gel sandwich are aligned in the alignment slot of the casting stand and then the glass plate assembly is snapped into one of the casting siots. The rubber gasket provides a leak-proof seal without grease or an agarose plug.
Inner Cooling Core
Once the gels are cast, the clamp assemblies are snapped onto the inner cooling core to form the upper buffer chamber. The molded U-shaped gaskets provide a leak-free seal without grease. The upper buffer is in direct contact with the inner glass plate of the gel sandwich to provide even heat distribution over the entire gel length, preventing thermal band distortion during electrophoretic separations.
The inner cooling core houses both the upper and lower electrodes and the connecting jacks. The anode or lower buffer chamber jack is identified with a red marker and the cathode or upper chamber jack with a black marker.
Lower Buffer Chamber 'and Lid
The lower buffer chamber and lid combine to fully enclose the Mini-PROTEAN II cell during electrophoresis, providing electrical insulation. The lid cannot be removed without disconnecting the electrical circuit. This lid and buffer chamber can be used with a variety of different electrode modules to convert the Mini-PROTEAN II cell into a Mini Trans-Blot® cell, a Mini-2D electrophoresis cell or an electro-elution cell for preparative recovery of proteins and nucleic acids. For more information, see Section 3.4 or ask for Bulletin 1273.
Equipment and Accessories
Mini-PROTEAN II Siab Cell
Mini-PROTEAN II Cell, 10 well combs, 0.75 mm spacers, includes inner cooling core with gaskets, Iower buffer chamber, lid with power cables, Glass Plates (3 sets), 2 Clamp Assemblies, 10 well, 0.75 thick combs (2), 0.75 mm thick spacers (4), Casting Stand with Gaskets, leveling bubble, and instructions.
MinI-PROTEAN II Cell, same as above without combs and spacers.
Accessories
Casting Stand wlth Gaskets, to cast 1 or 2 gels
Replacement Gaskets, casting stand, 2
Clamp Assembly, to cast 1 gel
Replacement Gaskets, inner cooling core, 2
Glass Plates, 10 sets*
Glass Plates, 10 inner plates
Glass Plates, 10 outer plates
Buffer Tank and Lid
Mini-PROTEAN ii Electrode Assembly
Replacement Power Cabies, 1 pair
*One set = one short (inner) plate and one Jong (outer) plate (enough to cast one gel).