Biometrica COPAS Select
| Objektnummer | B00016988 |
|---|---|
| ID-number | 016988 |
| Object name | Biometrica COPAS Select |
| Status | Stock unit |
Product group: Flow cytometer
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
|
Country |
Possible payment methods |
Comment |
|
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
|
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
|
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
|
Status |
Condition |
Comment |
|
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
| In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
|
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
|
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
|
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
manufacturer: Biometrica
model: COPAS Select
annotation: Dokumente engl.
The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.
SYSTEMS SPECIFICATIONS COPAS SELECT
1. INTRODUCTION
The COPAS TM SELECT (Complex Object Parametric Analyzer and Sorter) is an Instrument for analyzing and sorting objects from 20-350 microns in diameter and less than 2mm in length Applications include Drosophila embryos and other like sized mode) organisms and large cellular clusters. This continuous flow system is capable of analyzing small and large quantities of objects using five parameters: size, optical density and up to three channels of fluorescence. Objects are passed axially, one by one, through a focus of a laser beam; the resulting signals are then detected and recorded by a forward scatter detector and fluorescence detectors. Relative size is measured by an axial light-loss detector, which records the time that the light blockage signal remains above a pre-set threshold level; this parameter corresponds to the time of flight (TOF). The optical density of the object is determined by the total integrated signal of the light blockage; this parameter is the object's extinction (EXT). The fluorescence intensity (FLU) can be simultaneously determined at three different wavelengths by the excitation and emission filters in the system. TOF is related to an object's axial length, EXT is related to how dark or transparent an object is, and FLU is related to the amount of fluorescing compound that is present. Sorting and dispensing decisions are based on user-selected ranges of EXT, TOF, and FLU that are entered through our COPAS software. Objects can be dispensed into microtiter plates or stationary receptacles. Using a unique, pneumatic sorting mechanism, the COPAS is gentle enough to sort and dispense live organisms without affecting their viability.
2. GENERAL PERFORMANCE SPECIFICATIONS
The objects referred to in the specifications below are specifically for Drosophila embryos, with broad application for other objects including cell clusters, beads, and other objects of similar size and shape. A selected region refers to Operator specified ranges in EXT, TOF and FLU.
Analysis and Counting Rate:
Maximum 25 objects per second with Standard COPAS software (or 100 with Advanced Acquisition Package software) based on maximum sample concentration and nominal sample flow rates.
Automated Dispensing Fill Time for 96 Well Microtiter Plates:
1.5 2 minutes per plate with 1 object per well selected, coincidence check software operating, nominal sample concentrations, and an acquisition rate of 20 objects per second in the selected region.
Automated Dispensing Accuracy:
Greater than 98% of wells filled have one or more objects. Of the filled wells, less than 5% may have 2 or more objects.
Sample Viability after Sorting and Dispensing:
There is no decrease in the viability of a live organism after having passed through our machine.
3. FLUID/ MECHANICAL SPECIFICATIONS
Sample Capacity: 250 milliliters; 40 ml Option available
Sample Concentration: Adjustable, maximum 500 objects per milliliter
Sample Flow Rate: Adjustable, nominally 6 milliliters per minute
Sample Mixing: Magnetic stirrer bars for mixing in sample cup
Sheath: Proprietary Union Biometrica sheath. The sheath contains nontoxic, non-ionic surfactant.
Sheath Capacity: 10 liters
Sheath Flow Rate: Adjustable, nominally 25 milliliters per minute
Cleaner Capacity: 1 fiter
Waste Capacity: 10 liters
Sorter Mechanism: Air jet fluid diverter
4. OPTICAL ASSEMBLY DESIGN SPECIFICATIONS
Laser: Typical laser choices include: UV 325 nm He-Cd, UV 375, 405, 488, 488/514, 561, 635, 640, 670, Ar-Kr multi-line. New lasers are being introduced all the time: please contact us if you need something different
Laser Optics: Lens assembly creates an elliptical analysis beam at the plane of the
flow cell. The 1/e2 dimensions of approximately 1 mm as measured in air with the flow cell absent.
Flow Cell: Square cross-section quartz flow cell with 500 micron square crosssection inner bore.
Detectors:
PIN Photodiode for measuring extinction (EXT) and time of flight (TOF).
Photomultiplier tubes for measuring fluorescence.
Ambient Light: Optical assembly is sealed and unaffected by normal room light.
5. ELECTRONICS SPECIFICATIONS
Processors: Three microprocessors controlling XY-stage motion, sorting/acquisition and fluidic control valves.
Analog: 5 acquisition channels with software settable gain, Integrator scaling, triggering threshold and 12 bit ADC. Variable voltage control for fluorescence PMT gain, walte pump speed, and mixer speeds.
Computer: IBM compatible PC with color monitor
INSTALLATION SPECIFICATIONS
Workspace: Permanent, open, level, vibration free space with a recommended work area of 2m Wide x 0.6m Deep. Actual instrument is 0.7m W x 0.6m D x 0.6m H (1.1 m with the lid up).
System Weight: 100 lbs (45 kg) not including Computer (approx. depending on options)
Power: Place the COPAS SYSTEM within 6 feet (2 meters) to the power outlets.
For USA and Canada: Two single phase, 120VAC, 20 amps, 50/60 HZ, on separate dedicated lines with protective earth grounds, using the detachable cords supplied. *lf the optional Air Compressor is used, it is recommended that a third dedicated line (100-120VAC, 15 Amp, 50/60 HZ, single phase on a dedicated line with protective earth ground) is provided, although it may be connected to the line with the COPAS instrument. Always ensure that local electrical codes are followed.
For Continental Europe: Two, single phase, 220/240VAC, 16 amp, 50/60 HZ, on separate dedicated lines with protective earth grounds using the detachable power cords provided or CE7/VII approved equivalent detachable cords. *lf the optional Air Compressor is used, it is recommended that a third dedicated line (220/240VAC, 10 Amp, 50/60 HZ, on separate dedicated lines with protective earth ground) is provided, although it may be connected to the line with the COPAS instrument. Always ensure that local electrical codes are followed.
Pressurized Air: 25-100 psi of filtered, at 2 CFM, non-condensing, watet and oil free supplied by house air or optional UBI supplied Compressor
Temperature: 60°F (15°C) to 85°F (30°C) environmental temperature limits. Temperature should not vary more than +/- 1 degree C from the time of experimental setup through completion. The System generates approximately 3800 BTU/Hr.
Humidity: 0 to 85% non-condensing environmental relative humidity limits.