Binder BD 115
| Objektnummer | B00025168 |
|---|---|
| ID-number | 025168 |
| Object name | Binder BD 115 |
| Status | Stock unit |
Product group: Incubators
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
|
Country |
Possible payment methods |
Comment |
|
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
|
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
|
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
|
Status |
Condition |
Comment |
|
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
| In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
|
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
|
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
|
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Manufacturer: WTB Binder
Model: BD 115
The following illustrations and descriptions are model-related and taken from brochures.
They do not reflect the scope of delivery of the system.
The exact scope of delivery can be found in the offer text.
Features / Equipment
· Electronically controlled APT.line™ preheating chamber technology
· Temperature range 5 °C above room temperature up to 100 °C
· DS controller with integrated timer 0 to 99 h
· Digital temperature setting accurate to a tenth of a degree
· Over-temperature monitor class 3.1 (DIN 12880) with optical alarm
· Adjustable air exchange through front air flap adjuster and rear
Exhaust pipe Ø 50 mm
· Inner glass door
· RS 422 interface for communication software APT-COM™ DataControlSystem
· Units up to 115 liters are stackable
· 2 inserts, chrome-plated
· BINDER test certificate
Technical specifications
|
BD 23 |
BD 53 |
BD 115 |
BD 240 |
BD 400 |
BD 720 |
|
|
outside dimension |
|
|
|
|
|
|
|
width (mm) |
433 |
634 |
834 |
1034 |
1234 |
1234 |
|
Height (including feet/castors) (mm) |
492 |
617 |
702 |
822 |
1022 |
1528 |
|
Depth (plus door handle, l-bar and exhaust pipe 85(mm)) |
516 |
575 |
645 |
745 |
765 |
865 |
|
Back distance to wall(mm) |
100 |
100 |
100 |
100 |
100 |
100 |
|
Wall distance laterally (mm) |
100 |
160 |
160 |
160 |
160 |
160 |
|
vapor space volume (l) |
36 |
70 |
142 |
283 |
457 |
808 |
|
Number of doors (piece) |
1 |
1 |
1 |
2 |
2 |
2 |
|
|
|
|
|
|
|
|
|
inside dimension |
|
|
|
|
|
|
|
width (mm) |
222 |
400 |
600 |
800 |
1000 |
1000 |
|
height (mm) |
330 |
400 |
480 |
600 |
800 |
1200 |
|
depth (mm) |
277 |
330 |
400 |
500 |
500 |
600 |
|
Interior volume (l) |
20 |
53 |
115 |
240 |
400 |
720 |
|
Sliding rails (no. serial number/max.) |
2/3 |
2/4 |
2/5 |
2/7 |
2/10 |
2/16 |
|
Load per grid (kg) |
12 |
15 |
20 |
30 |
35 |
45 |
|
Permissible total load (kg) |
25 |
40 |
50 |
70 |
90 |
120 |
|
Weight (empty) (kg) |
26 |
43 |
61 |
93 |
135 |
191 |
|
|
|
|
|
|
|
|
|
temperature range |
|
|
|
|
|
|
|
Temperature range approx. 5 °C above room temperature to (°C) |
100 |
100 |
100 |
100 |
100 |
100 |
|
Spatial temperature deviation 1) |
|
|
|
|
|
|
|
at 37 °C (± °C) |
0.5 |
0.5 |
0.4 |
0.5 |
0.5 |
0.5 |
|
at 50 °C (± °C) |
1.8 |
1.1 |
0.8 |
0.9 |
0.9 |
0.8 |
|
Temporal temperature deviation (± °C) |
|
|
|
|
|
|
|
at 37 °C (± °C) |
0.2 |
0.1 |
0.1 |
0.1 |
0.1 |
0.1 |
|
at 50 °C (± °C) |
0.3 |
0.1 |
0.1 |
0.1 |
0.1 |
0.1 |
|
heating-up time 1) |
|
|
|
|
|
|
|
to 37 °C (min) |
49 |
38 |
62 |
70 |
105 |
84 |
|
to 50 °C (min) |
32 |
59 |
91 |
115 |
132 |
90 |
|
Recovery time after 30 sec door open 1) |
|
|
|
|
|
|
|
at 37 °C (min) |
3 |
5 |
5 |
5 |
6 |
4 |
|
at 50 °C (min) |
4 |
7 |
7 |
6 |
29 |
24 |
|
|
|
|
|
|
|
|
|
electrical data |
|
|
|
|
|
|
|
IP protection class according to EN 60529 |
IP 20 |
IP 20 |
IP 20 |
IP 20 |
IP 20 |
IP 20 |
|
Rated voltage (±10%) 50/60 Hz (V) |
230 |
230 |
230 |
230 |
230 |
230 |
|
Rated power (W) |
200 |
400 |
400 |
680 |
850 |
1250 |
|
Blank at 37°C (W) |
11 |
11 |
20 |
33 |
56 |
80 |
|
|
|
|
|
|
|
|
1) to 98% of the target value
All specified technical data are relevant for standard devices at an ambient temperature of + 25 °C and a mains voltage fluctuation of ± 10 %. These mean values, which are typical for series devices, were determined according to the BINDER company standard and are based on the recommended wall clearances of 10% of the height, width and depth of the interior. Deviating ambient temperatures as well as production-related device-specific variances can lead to deviating performance data.
We therefore recommend individual customer-specific calibration or validation for applications at the limits of the permissible ambient temperature range.