Behring BCT

ID-number: 014243
Status: Archived Product?The unit is no longer available.
Shipping:
Description:
Dade Behring Coagulation timer BCT. YoC 1999.
siehe Storeview
More Information
Objektnummer B00014243
ID-number 014243
Object name Behring BCT
Status Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Behring

Modell:            BCT

Kommentar:   Dokumente deut.

Nachfolgende Abbildungen und Beschreibungen sind modellbezogen und aus Prospekten entnommen.

Sie geben nicht den Lieferumfang des Systems wieder.

Den exakten Lieferumfang entnehmen Sie bitte aus dem Angebotstext.

Der Behring Coagulation Timer (BCT) besteht aus einem oder zwei Analyser(n), einem Personal Computer und einem Druk­ker.

Der PC steuert den/die Analyser und verwaltet die Daten. Er kann an einen Host-Rechner angeschlossen werden, welcher Messungen anfordert und Ergebnisse erwartet.

Der Analyser wird mit Proben, Reagenzien und Meßküvetten bestückt.

Die Proben werden in Primärgefäßen in den Probenrotor ein­gesetzt. Für die gängigen Primärgefäße sind spezielle Adapter (Zentrierringe) erhältlich. Für kleine Volumina stehen spezielle Probencups zur Verfügung. Notfall-proben (STATs) können jederzeit zur bevorzugten Bearbeitung nachbestückt werden.

Der Analyser kann wahlweise probenorientiert oder test­selektiv arbeiten. Gemäß der Arbeitsliste werden koagulome­trische, chromogene und immunologische Tests mit den Pro­ben durchgeführt. Einzelne Tests können zu Profilen zusam­mengefaßt werden.

Die Ergebnisse werden in die Arbeitsliste eingetragen, in einer Datenbank gespeichert und, falls konfiguriert, automatisch ausgedruckt. Falls der Analyser an ein Host-System ange­schlossen ist, können die Daten an diesen übertragen werden. Nach einer Kalibration kann eine Umrechnung der Rohwerte in Konzentrations- oder Aktivitätseinheiten erfolgen.

Technische Daten

Allgemeine Be­schreibung

Behring Coagulation Cups      4 ml Probengefäße mit Eich­strich

Gerätetyp                                 Gerinnungsvollautomat

Anwendung                             koag. Gerinnungstests:

                                               PT, aPTT, TZ, Fibrinogen, usw. Einzelfaktoren, Protein C,usw.

chromogene Tests:

                                               PT, aPTT,Plasminogen Einzelfaktoren AT III(A),Faktor XIII,usw.

Arbeitsweisen                          Random Access (proben-orientiert)

                                               Batch (testselektiv)

                                               Notfall

Meßprinzip                               Photometrisch mit

            Magnetrührer zur Homogeni­sierung des Testansatzes und Steigerung der Empfindlichkeit

Empfindlichkeit                        PT> 10% d. Norm;

Probendurchsatz                    PT 185/h; aPTT 70-100/h (abhängig vom Reagenz); PT/aPTT/TT/AT III (A) 35/h

Küvetten-Volumen                   150-350 µl

Pipettier-Volumen                    2-180 µl

Meßkanäle                               2 x 2 Kanäle

Kalibration                                           Auf Anforderung mit Speichern und Darstellen der Referenz-kurven

Notfall                                      Bis zu drei Notfallproben können pro Probenrotor wäh­rend der Messung einge­schleust und bevorzugt abge­arbeitet werden

Analyser

Nachbestückung                     jederzeit möglich, die Meßreihe wird zur Nachbestückung von Proben unterbrochen (in 3er Gruppen)

Reagenzblock                         auf 15 °C ± 0,5 °C gekühlte Positionen für Reagenz­flaschen (erhöhte Reagenz­stab i I ität) :

                                               -10 Positionen für

                                                 15 ml Flaschen bzw.

               5 ml Flaschen in Adaptern;

   davon 2 mit Magnetrührern

- 3 Positionen für

                                                  5 ml Flaschen

Reagenzflaschen                    5 ml und 15 ml Flaschen

                                               Restvolumen 5 ml Flasche:

                                               - ohne Rührer: 500 µl

                                               - mit Rührer: 800 µl

                                               Restvolumen 15 ml Flasche:

                                               - ohne Rührer: 1300 µl

                                               - mit Rührer:1600 µl

Cupblock                                 14 Positionen für Cups mit Kontroll- und Mangelplasmen

Probenrotor                             a) Probenrotor Oa (BFA),

                                               für 75 mm Primärgefäße

                                               (für Proben ohne Barcode):

                                               48 Positionen für Primär‑

                                    gefäße und Cups, davon

                                               - 45 Positionen für Rou­tineproben, Standard-, Kalibrier- und laboreigene Poolplasmen

                                              

                                               b) Probenrotor Ob (BFA),

                                               für 100 mm Primärgefäße

                                               (für Proben ohne Barcode):

                                               48 Positionen für Primär‑

            gefäße und Cups, davon - 45 Positionen für Rou­tineproben, Standard-, Kalibrier- und labor‑

                                               eigene Poolplasmen

                                               c) Probenrotor 1 ( BCT)

            (für Proben mit Barcode):

44 Positionen, davon

- 28 Positionen für Primärgefäße und Cups, inkl. 3 Positionen

   für Notfallproben

                                               -16 Positionen für Behring Coagulation Cups ohne Barcode

Probengefäße                         a) Primärgefäße:

                                               8 ml BD Vacutainer

                                               5 ml Sarstedt Monovette

                                               4,5 ml BDVacutainer

                                               3 ml Sarstedt Monovette

                                               b) Sekundärgefäße:

            4 ml Behring Coagulation Cup für pädiatrische Proben Restvolumen: 150 µl Minimales Proben­volumen für eine Bestimmung: 200-250 µl, je nach Testmethode

Meßrotoren                              2 parallel arbeitende Meßrotoren, mit:

                                               - je 32 auf 37 °C ± 0,3 °C temperierten Küvetten­positionen,

                                               - geschwindigkeitsgesteuerten Motoren: 100-600 U/min

Photometer                             Lichtquelle: Halogenlampe 12 V/20 w

                                               Lichtleiter: Glasfaserkabel

Filter:                                       Interferenzfilter 405 nm, 340 nm,620 nm und2 freie Positionen

Küvetten                                  Küvettenrotoren (BFA/BCT Dispo-Systeme) mit 32 Einzelküvetten, die mit Mixern bestückt sind.

Pipettor                                               beweglich in 3 Richtungen (x,y,z),Pipettornadel temperiert auf 37 °C ± 0,3 °C

Dilutor                                      500 µl Spritze

            Kolbenhub: 60 mm Auflösung: 6000 Schritte Schrittweite: 0,01 mm max. Schritt­geschwindigkeit:

                                               4000 Schritte/s

                                               Zeit für einen Vollhub: 1,5 s

                                               max. Spülleistung: 3 ml/s

                                               Gravimetrische Messun­gen (250 µl Spritze, Schlauch 1,0 mm):

                                               Volumen      Unrichtigkeit         Vk

                                                                  %                          %

                                               3µl               +/- 3,0                   1,5

                                               10µl             +/-1,5                    0,5

                                               50 µl            +/-1,3                    0,2

                                               100 µl          +/-1,2                    0,15

Spülung                                   passiv, je Spülung mit dest. Wasser (ca. 4 ml)

                                               a) normal

                                               b) intensiv bei thrombinhaltigen Reagenzien

                                               c) Desinfektion

Spülflüssigkeit                         - Dest. Wasser (normale Spülung)

            - Waschlösung (intensive Spülung bei thrombinhaltigen Reagenzien), (100 µl/Zyklus)

- Desinfektionslösung

Abwasserentsorgung              kanalisiert (nach Vorlage von Desinfektionsmitteln)

Temperierung                          Meßrotoren,13 Reagenz­positionen, Pipettornadel

Verbrauchsmaterial                 Küvettenrotoren mit Mixer

Computer

Typ                                          EPSON Endeavor TM C

CPU (Zentraleinheit)                Intel 80486 DX Prozessor, 33 Mhz, 32 Bit

Arbeitspeicher                         20 MB

Diskettenlaufwerk                    31/2" mit 1,44 MB

Festplatte                                270 MB

Monitor                                     TARGATm 1499 NL,

                                               14" VGA Farbmonitor, max. 1024 x 768 Pixel Auflösung

Tastatur                                   alphanumerische Tastatur (PS/2 kompatibel, Typ Marquard)

Maus                                        EPSON Microsoft Maus (PS/2 kompatibel)

Betriebssystem                      Windows NT 3.5 (dadurch Multitasking und netzwerk­fähig)

Software                                  BCT Treiber, BCT 1.0 oder aktuellere Version

Drucker                                   je nach installiertem Drucker­treiber

Maße und Gewichte

Analyser                                  1050 x 513,5 x 526 mm (B x T x H), ca. 60 kg

Computer                                370 x 412 x 120 mm (B xT x H), 7,5 kg

Monitor                                     366 x 386 x 380 mm (B xT x H), 12 kg

Spannung und Leistungsaufnahme

Analyser                                  115/120/230/240 V (± 10%), Hauptsicherung:

                        - bei 115/120 V 4 AT

                        - bei 230/240 V 2 AT 50-60 Hz, 200 VA

                        Überspannungskategorie: Klasse II

                        Verschmutzungsgrad: Klasse 2

Computer                                90-264 V, 47-63 Hz, 145 W max.

Monitor                                     120-230 V, +/- 5°/0,50/60 Hz (automatisch), 76 W

Umgebungsbedin­gungen

Umgebungstemperatur           +10 °C bis +30 °C

Relative Luftfeuchtigkeit          kleiner 85 %, nicht kondensierend