Becton Dickinson FACS Vantage
Objektnummer | B00010644 |
---|---|
ID-number | 010644 |
Object name | Becton Dickinson FACS Vantage |
Status | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.
The FACS Vantage TM , BDIS's new cell sorter, was designed for ease of operation and provides ample room in which to work. With its stream-viewing video camera and monitor, an eight-trace oscilloscope, a wide selection of lasers, an optional third laser, FACS Vantage uses the latest technology in flow cytometry.
You can use FACS Vantage for research applications in:
Molecular Genetics to study
isolated chromosomes for developing chromosome-specific libraries
normal gene expression
abnormalities leading to disease
Cell Cycle Analysis to
quantify the proliferative characteristics of cells and cell populations
gain knowledge about the fraction of cells at risk from cell-cyclespecific cytotoxic agents, enabling maximal tumor killing and minimal normal cell death
quantify phase fractions, phase durations, doubling times, labeling index, and growth fractions by using modeln or bromodeoxyuridine as a marker for cellcycle traverse studies
employ the monoclonal antibody Ki-67, a nuclear antigen that is found in proliferating cells, but not in resting cells
perform leukemia phenotyping, monitor cancer remission, and analyze rare events in cancer studies
Intracellular Calcium Measurement to
measure intracellular ionized calcium concentration to learn about a cellular functions
correlate calcium concentration with other parameters, such as cell-surface antigen expression
sort, based an calcium concentration
Fluorescence In Situ Hybridization (FISH) to
label, locate, and quantify specific nucleic acid sequences in cells or chromosomes, alter sorting specific cells an FACS Vantage
enhance FISH techniques by adding the FACS Vantage spatial resolution, convenience, speed, and sensitivity
Large Particle Analysis and Sorting (using the available MacroSORT Option) to
characterize and sort islets of Langerhans for diabetes research including transplantation studies and encapsulation
measure nuclear genome sizes in higher plants by producing a suspension of cells without walls (protoplasts) and by measuring the DNA content
evaluate DNA content by studying megakaryocytes
Microbiology to
analyze changes in cellular functions brought about by intracellular organisms such as viruses, bacteria, and protozoa
study cell-cycle kinetics and regulatory mechanisms governing cell growth and replication
monitor (bacteria and other) microorganisms used in industrial processes or occurring as contaminants in materials ranging from drinking water to crude oil.
Optional Laser
Enterprise II Ion Laser
The Enterprise ion Laser consists of a water cooled Laser head and a switching regulated air cooled power supply. Enterprise is a small frame argon ion Laser available with multiple wavelength outputs including UV, UV/488 nm, and UV/488/515 nm outputs.
The Enterprise System can be remotely controlled by an external device via a connector an the power supply (remote operation), which accepts analog commands and provides analog Status outputs, or directly from the front panel of the power supply (local operation).
System Specifications |
||||||
MODEL |
OPERATING WAVELENTH(S) |
Output Power (mW) |
Beam Diameter (1) (mm) |
Beam Divergence(2) (mrad) |
Waist Diameter (2) (mm) |
Waist Location(2) (m) |
621 |
UV (351 to 364 nm) (3) 488.0 nm |
50 150 |
0.88 1.21 |
0.73 0.82 |
0.70 0.84 |
0.81 1.15 |
(1) Beam diameter is measured at the output coupler which is 8.5 cm behind the front faceplate of the laser head assembly.
(2) The long-radius output coupler acts as a weak lens to transform the output beam parameters. The values listed for beam divergence, waist diameter and location take into account this weak lens effect. The value for beam waist location is measured from the outside of the front faceplate of the laser head assembly.
(3) Primary wavelength(s) used for light regulation. When the UV power level is set for the specified value, the visible power levels may be significantly higher than the specified values.
(4) Other wavelengths may be present.
Beam Characteristics |
|
PARAMETER |
DESCRIPTION |
Power Stability(1) |
<1% long-term (primary wavelength) |
Beam Pointing Stability(1) |
<5 µrad/°C typical |
Optical Noise(2) |
<1% RMS (0.75% RMS/6% peak-to-peak typical) |
Mode/ Mode Purity |
TEM 00 / M 2 < 1.10 |
Polarization Ratio |
100:1 |
(1) Maximum peak variation over any 30 minutes period after a 15 minute warm-up. (2) Measured with a 10 Hz to 2 MHz photodiode driving a resistive load. May be slightly higher if operated with one side of input line at ground potential (neutral). |
Weights and Dimensions |
|||
|
LASER HEAD |
POWER SUPPLY |
UMBILICAL CORD |
Length |
76.2 cm (30 in.) |
50.2 cm (19.75 in.) |
(2.4 m) 8 feet |
Width |
18.6 cm (7.31 in.) |
43.8 cm (17.25 in.)(2) |
--- |
Height(1) |
17.1 cm (6.35 in.) |
19.1 cm (7.5 in.) |
--- |
Diameter |
--- |
--- |
2.54 cm (1.0 in) (3) |
Weight |
|
|
|
Crated |
43 kg (94 lb) |
42 kg (93 lb) |
|
Uncrated |
27 kg (59 lb) |
35 kg (78 lb) |
|
(1) Without feet. (2) Does not include handles. (3) Not including connectors. |