Sold

Beckman VTi90

ID-number: 014098
Status: Stock unit
Preis auf Anfrage
Excl. 19% VAT , excl. Shipping Cost
siehe Storeview
Description:
Beckman Rotor VTi90. For Ultra centrifuge. Max 90000 rpm.
Quotation
siehe Storeview
More Information
Objektnummer B00014098
ID-number 014098
Object name Beckman VTi90
Status Stock unit

Product group: Centrifuges (rotors)

We can't find products matching the selection.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Beckman

Modell:            VTi90

Kommentar:    Dokumente engl.

The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.

Vti 90 Vertical Tube Rotor

(for use in Beckman Class H, R, and S Preparative Ultracentrifuges)



SPECIFICATION

Maximum speed                                                                               90 000 rpm

Density rating at full speed                                                                   1.7 g/mL
Relative Centrifugal Field* at maximum speed

At rmax (71.1 mm)                                                                           645 000 x g

At rav (64.5 mm)                                                                               585 000 x g

At r min (57.9 mm)                                                                            525 000 x g

k factor at maximum speed                                                                              6

Number of tube cavities                                                                                    8

Available tubes                                                                                 see Table 1

Nominal dimensions of largest tubes                                                   1/2 x 2 in

                                                                                                      (13 x 51 mm)

Nominal tube capacity                                                                             5.1 mL

Nominal rotor capacity                                                                           40.8 mL
Approximate acceleration time to maximum

speed (rotor fully loaded, in the

Optima XL Ultracentrifuge)                                                                         9 min
Approximate deceleration time from maximum

speed (rotor fully loaded and brake on,

in the Optima XL Ultracentrifuge)                                                         81/2 min

Weight of fully loaded rotor                                                             5,5 kg (12 lb)

Rotor material                                                                                        titanium

--------------------------------------------

*Relative Centrifugal Field (RCF) is the ratio of the centrifugal acceleration at a specified radius and speed ( rw 2 ) to the standard acceleration of gravity (g) according to the following formula:

wherer is the radius in millimeters, w is the angular velocity in radians per second (2πRPM/60), and g is the standard acceleration of gravity (9807 mm/s 2 ). After Substitution:

DESCRIPTION

The Wi 90 vertical tube rotor, rated for 90 000 rpm, is designed to centri­fuge up to eight 1/2-in. diameter Quick-Seal® tubes in an upright position. Used in class H, R, and S preparative ultracentrifuges, the rotor develops centrifugal forces that can efficiently band DNA or isolate proteins an density gradients. Up to 40.8 mL of gradient and sample can be centrifuged per run.

The rotor is made of titanium and is finished with black polyurethane paint. A rotor plug, tube spacer and, if necessary, a floating spacer, hold each tube in the rotor. A Hytrel gasket forms a closure around each rotor plug. Rotor plugs are red-anodized and spacers are black­anodized aluminum; floating spacers are Noryl plastic. Because of the weight of the rotor, there are no drive pins in the rotor drive hole.