Beckman-Coulter LH500

ID-number: 018153
Status: Archived Product?The unit is no longer available.
Shipping:
Description:
Beckman-Coulter Hematology analyzer LH500. YoC 2006
siehe Storeview
More Information
Objektnummer B00018153
ID-number 018153
Object name Beckman-Coulter LH500
Status Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

manufacturer :       Beckman-Coulter

model :                   LH500

annotation :           Dokumente engl.

 

 

 

High-Volume Performance in a Compact Design

The COULTER® LH 500 Hematology Analyzer helps increase productivity, enhances linearity, improves diff flagging and reduces false positive flagging—all in a compact design that fits your needs and your limited lab space. Plus, it offers advanced VCS technology, providing the greatest sensitivity, specificity and efficiency in white cell differential analysis.

 

 

Features

Increased Efficiencies Help You Manage Your Workload

Reduce repeat testing and save time with expanded linearity for WBC and Platelt counts

Improved flagging reduces review rate

Standardize lab processes across all shifts with user-defined decision rules

Save time with continuous automated sample loading for complete walkaway operation

 

Integrated Solutions Expand Your Lab’s Capabilities

Simplify supply ordering with reagents interchangeable between all LH series models

Eliminate additional technologist training with a common user interface

Common LH series core technologies provide closest correlation of results between instruments.

LH series data management capabilities include full decision support

Easy-to-use Windows-based software

Save valuable lab space with a compact design that complements existing instruments

Run STAT samples with minimal interruption of routine workflow

·           

Method and Technologies

CBC Analysis & Hgb

·   Coulter Principle: counting and sizing

·   Triplicate counting

· Coincidence correction

·   Pulse editing

·   Sweep flow

·   Extended platelet counting

·   Hemoglobin method equal in accuracy to reference method

·   LH Series Diluent and

COULTER ® LYSE S ® III diff reagent system

 

5-Part Differential Analysis

·   VCS Technology

·   LH Series reagent system

·    

Retic Analysis

·   VCSTM Technology

·   COULTER ® ReticPrepTM reagent system (New Methylene Blue)

·    

26 Parameters

WBC          RBC        PLT            RETIC #

NE#            HGB         MPV            RETIC %

NE%           HCT         PCT*      IRF

LY#        MCV      PDW*    MRV

LY%         MCH

MO                 MCHC

MO%        RDW

EO#

EO%

BA#

BA%

* For Research Use Only. Not for use in diagnostic procedures.

 

Sample Size

·   185 μ L whole blood, closed vial sampling

·   125 μ L whole blood, open vial sampling

·   50 μL whole blood, predilute mode

·    

Barcode Symbology
Positive Barcode ID

·   Codabar

· NW 7

·   Code 39 ®

·   Code 128

·   Interleaved 2-of-5

·    

LH 500 Workstation/Data Management

·   Windows 2000 operating system

·   Database capacity: 20,000 sets of results, graphics and listmode files

·   User-defined flagging

· Archive and transmit patient and QC to host computer

·   Decision rules criteria

 

 

Quality Control Management

·    Unlimited control files with unlimited runs on each file

·    Control and user-defined flagging

·    Upload and download information from a diskette

·     

Improved Linearity/Operating Ranges

Parameter            Linearity Ranges                                  Operating Ranges

WBC                  0.0 – 200.00 x 10 3 cells/ μ L         0.00 – 300.0 x 10 3 cells/ μ L

RBC                   0.0 – 7.00 x 10 6 cells/ μ L 0.0 – 9.99 x 10 6 cells/ μ L

HGB                   0.0 – 25.0 g/d     L                      0.0 – 99.9 g/dL

PLT                    0.0 – 2,000.0 x 10 3 cells/ μ L        0.0 – 3500 x 10 3 cells/ μ L

 

Parameter            Reportable Ranges                              Operating Range

MCV                   50.0 – 150.0 fL                           0.0 – 999.9 fL

Diff%                  0 – 100%                                              0 – 100%

Diff#                   0.00 – 200.00 x 10 3 cells/ μ L        0.00 – 300.00 x 10 3 cells/ μ L

RET%                0.00 – 30%                                           0.00 – 100.0%

RET#                 0.00 – 0.7900 x 10 6 cells/ μ L        0.0000 – 999.9 x 10 6 cells/ μ L

 

Precision

Parameter            @ Approximate Level                           Limit

WBC                    4.0 – 15.0 x 10 3 cells/ μ L                      ≤2.5% CV

RBC                     3.00 – 6.0 x 10 6 cells/ μ L                      ≤2.0% CV

HGB                     12.0 – 18 g/dL                           ≤1.5% CV

MCV                     80 – 100 fL                                           ≤2.0% CV

RDW                    12 – 15%                                              ≤2.5% CV

PLT                      200 – 500 x 10 3 cells/ μ L             ≤5.0% CV

MPV                      7 – 12 fL                                               ≤3.0% CV

NE%                     50 – 60%                                              2SD ≤3.0

LY%                      25 – 35%                                              2SD ≤3.0

MO%                    5 – 10%                                                2SD ≤2.0

EO%                    2 – 5%                                                  2SD ≤1.0

BA%                     0.5 – 1.5%                                            2SD ≤1.0

RET %                 <1.00%                                                 1 SD ≤0.23 or 23.0% CV

RET %                 1.00 – 4.00%                                        1 SD ≤0.23 or 17.0% CV

RET %                 4.01 – 15.00%                           1 SD ≤0.68 or 15.0% CV

 

Accuracy                                                                                                            Mean Difference % using

Parameter                                      Mean Difference               LH 750 Hematology Analyzer

WBC      0.00 – 100.0                     ±0.2                                 3.5%

100.1 – 200.0                    N/A†                                12.0%

RBC                                               ±0.05                                2.0%

HGB                                               ±0.2                                 3.0%

MCV                                               N/A†                                 2.0%

PLT                                                ±10                                    7.0%

MPV                                                N/A † 5.0%

Lymphocyte                                    ±1.5

Monocyte                                        ±1.5

Neutrophil                                       ±2.0

Eosinophil                                      ±0.5

Basophil                                         ±0.5

RET % Range 0.00 – 30.00% ±1.50

† Both requirements must be met.

 

Dimensions/Weight

                          Height               Width              Depth               Weight

Anal yzer             84.84 cm     61.5 cm       69.85 cm     94.5 kg

                          (33.4 in)            (25.1 in)          (27.5 in)            (210 lb)

Computers         43.18 cm          19.7 cm          47.6 cm            9.7 kg

                          (17.0 in)            (7.75 in)          (18.75 in)          (21.5 lb)

LCD Display      41.9 cm            40.4 cm          19.6 cm            7.34 kg

                          (16.5 in)            (15.9 in)          (7.7 in)              (16.3 lb)

 

Temperature, Ambient Operating

18° – 29°C (65 – 85°F)

 

Humidity

0 – 95% non-condensing

 

Throughput

Up to 75 samples/hour in Automatic mode

Product group: Hematology