Philips PW 2400

ID-number: 007070
Status: Stock unit
Preis auf Anfrage
Excl. 19% VAT , excl. Shipping Cost
siehe Storeview
Description:
Philips X-ray spectrometer type PW 2400. With spectrometer with 8 crystals.X-ray valve. 3 collimators. Sample-changer 30x PW 2510. refrig. aggregate.generator. Jun-Air compressor. Purch. in 1997. Newprice: 141.117,- Euro.
Quotation
siehe Storeview
More Information
Objektnummer B00007070
ID-number 007070
Object name Philips PW 2400
Status Stock unit

Product group: X-Ray analysis

We can't find products matching the selection.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

manufacturer :       Philips

model :                   PW 2400

annotation :           Dokumente engl .

 

 

 

Technical Specification

 

Safety Specifications

 

Electrical                                               IEC 348 Class 1

Safety                                                    CSA C22.2 No. 151 - M1986

Electro-Magnetic:                                  EN 55011

Compatibility                                          EN 55022

FCC vol II, part 15, subpart J

VDE 0871 part 1

CISPR 16

Verfugung 1046

IEC 801 - 2, 3, 4, 5.

Radiation:                                              Information Letter No. 591 of the Canadian "Health Protection Branch" r egarding Regulations, Part XVIII, Cabinet X-ray Equipment.

Code of Practice for Protection against Ionizing Radiation Emitted from X-ray Analysis Equipment (1984)

UL 187

DHEW Publication (FDA) 76-8035

NBS Handbook 111

NBS Handbook 114

Verandnung uber den Schutz vor Schaden durch Rontgenstralen ( RoV 1987)

lonising Radiation Regulations 1985 (GB).

 

 

 

 

Cabinet

 

Height

1094 mm

 

Width

1409 mm

 

Depth

961 mm

 

Weight

Approximately 700 kg

 

Temperature

30°

 

 

 

 

Control

 

The instrument is microprocessor controlled and receives the instruction via a RS232 port from a PC. For service an extra port is available to connect the service PC. For remote service an in/output port is available to do remote service.

 

 

 

 

Sample Handling

 

Airlock volume

115 cm³

 

Loading Operation

2 position internal sample changer

 

Sample introduction time

Air                     <    5 seconds

Nitrogen            < 15 seconds

Vacuum            < 10 seconds

Helium              < 15 seconds

 

Time to change sample Position

2 seconds

 

Airlock pumping time

4 to 60 seconds (programmable)

 

Sample spinner

30 rpm

 

Sample diameter

52 mm maximum

 

Sample thickness

40 mm maximum

 

Sample weight

4 N (400 g) maximum including sample holder (also for sample changer)

 

Medium

N 2 /He/Vacuum

The Vacuum system is standard build in the instrument. The He /N 2 flushing system is an option.

 

Vacuum level

< 13 Pa (clean Steel sample)

 

Helium consumption

1 l/min

1 l/sample

 

and PW2662 (Vac. Scanner )

0.5 l/min. per Vacuum Scanner

 

 

 

 

Compressed Air System

 

Air pressure

Minimum 0.4 MPa

Maximum 0.5 MPa

 

Quality

Instrument air without oil lubrication

 

 

 

 

Water System

 

Temperature control, heat exchanger and cathode cooling

Min         5 I/min

Max     11 l/min

 

Water pressure

Min 0.35 MPa

Max 0.8 MPa

 

Water temperature

Min 8°C

Max 20°C

 

Closed cooling system

3 - 4.5 Iitres de-ionised water

 

Cathode cooling

1 - 2 l/min.

 

 

 

 

Temperature Control

 

Temperature setting

30°C ±1°C

 

Temperature stabilisation

±0.05°C

 

 

 

 

X-ray Tube (End Window)

 

Voltage

+60 kV maximum

 

Current

125 mA maxinnum

 

Load

3 kW maximum.

 

Focal Spot

7.5 - 12.5 mm toroidial

 

Anode

Rh target

 

Filament voltage

10V Max.

 

Filament current

11,5A Max.

 

Cooling water Anode

Min flow 3 l/min of de-ionised water

 

Cooling water window

Min flow 1 l/min. tap water

 

 

 

HT Supply

 

Output power

Up to 3kW

 

Output voltage

+10 kV to +60 kV, in 1kV steps

 

Output current

10 mA to 125 mA , in lmA steps

 

Stability kV

<10 V per 1% mains voltage variation

 

Stability mA

<10 µA per 1% mains voltage variation

 

Temperature Drift

100 ppm /°C for HT and Current

 

Supply voltage

180 to 264 V

 

Supply frequency

47.5 to 63 Hz

 

Power consumption

8.4 kVA Cos. Phi. 0.71 (for complete spectrometer)

 

Minimum fusing

40 A, > 35 A (R.M.S.)

 

Safety

The HT supply is fully protected against short circuits. It conforms to the safety requirements of IEC 348. The system is certified by the CSA under C22.2 No. 151 - M 1986. HT cannot be generated until all safety requirements are fulfilled. This includes the safety circuit which comprises the two independent safety loops both of which are associated with the HT key switch on the front panel of the spectrometer. In the event of any malfunction, the generation of HT is prevented or the HT supply is switched off. lt cannot be re-activated until the cause of the failure is rectified.

 

Control

The HT supply is controlled by the spectrometer system controller.

 

 

 

PW2400 Optical Path

 

X tal chamber volume             22 dm³

 

 

 

Tube Filters

 

Number of positions

5 (Positions 2 - 6)

 

Filters                                                            Material           Thickness (micron)

                              ----------------------------------------------------------------------------

                              PW2418/10                     Brass               100

                              PW2418/20                     Al                      200

                              PW2418/30                     Brass               300

                              PW2418/75                     Al                      750

                              PW2418/99                     Pb                     1000

 

 

 

Collimator Mask

Number of positions                                    4

Sizes                                                           48, 37, 27 & 30 mm

Time to change                                           < 2.5 sec

 

 

 

Collimators

Primary collimators                                                       Spacing

( microns )

PW2478/10           High Resolution

PW2478/15           150

PW2478/30           300

PW2478/55           550

PW2478/70           700

                                                             PW2478/00       4000

Collimator dimensions

width 30 mm

height 20 mm

 

Number of positions

3

 

T ime to change

< 2.5 seconds

 

Secondary Flow Detector collimator

Spacing    0.45 mm

 

 

 

Crystal Changer

 

Crystal changer

8 positions

 

Time to change

< 2 seconds

 

X tal size

length 75 mm

width 30 mm

 

Crystals

LiF 420, LiF 220, LiF200, Ge 111, InSb 111, PE 002, TLAP 100, PX1, PX3, PX4 PX5 and PX6

 

 

 

Detectors

 

Detectors

Argon flow detector + scintillation detector or argon flow detector + sealed detector + scintillation detector

 

Detector windows

1, 2 or 6 micron polypropylene for flow detector, 200 micron Be for sealed detector and 300 micron Be for scintillation detector

 

Operational angles

Flow & sealed detectors 13° < 2Θ° <148°

scintillation detector 0° < 2Θ° <104°

 

Flow gas consumption

1 Nl /hour

 

Flow gas stabilisation

Pressure     0.05 - 0.09 MPa

 

Detector HV Unit

900V and 2025V max. selectable by jumpers.

(900V - Scintillation counter - 2025V - Flow and Sealed Xenon counter)

Programmable via the software.

 

Fixed channel positions

2

 

 

 

Beam Stop

 

Single beam stop, moved by tube filter drive mechanism.

 

 

 

Detectors

 

Types

Argon flow detector

Neon 25µm. detector

Neon 50µm detector

Krypton detector

Xenon detector

Scintillation detector

 

Detector HV Unit

One HV Unit per 2 detectors of the same type

0 - 1650 V or 0 - 2250 V selectable by jumper

(900V Max. - Scintillation counter

(2025V Max. - Flow and Sealed Krypton and Xenon counters)

(1650V Max. - Neon Sealed counter)

Programmable via the software

 

 

 

PW2400 Goniometer

 

Θ/2Θ system                                         De-coupled

AnguIar range                                         0 - 148° 2Θ

Slewing speed                                        1200° 2Θ/min

Scan speed selectable                           0.001° - 2° 2Θsec

Minimum increment                                0.0025° 2Θ

Angular reproducibility                            < 0,001° 2Θ

 

 

 

Counting Electronics

 

PW2400/00

Multi channel analyser                            1 per detector

Number of channels per MCA                256

Max counts per channel                         2 24

Timer                                                      Programmable up to 655 seconds

Detector pulse amplification                   Microprocessor controlled

Lower level                                             µP controlled, 0 - 255    1 Channel/steps

Upper Ievel                                              µP controlled, 0 - 255   1 Channel/steps

Correction for dead time                        Yes, by software

Sinus theta correction                            Yes, by software

Pulse shift correction                            By hardware   (can be switched on/off from the

                                                             software )

Data handling of spectrum                    Possible

Maximum count rates                           3 MCPS with a flow detector. The maximum count rate is dependent on the detector being used.

Detector identification                           On MCA PCB

High voltage detector                            Microprocessor controlled

 

 