Applikon ADI 2016
Objektnummer | B00011050 |
---|---|
ID-number | 011050 |
Object name | Applikon ADI 2016 |
Status | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Firma: Applikon
The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representating the delivery volume. The exact delivery content you will find only in the offering text.
ANALYSIS
Method: The ADI2016HD Titro Analyzer performs a titration with Hydrochloric acid for quick, simple and accurate analysis of small amounts of Sodium hydroxide.
Principle: After sampling a titration is performed with Hydrochloric acid up to the ferst inflection point. Titre solution is added beyond the equivalence point. The inflection point is detected automatically by recording the change of pH/mV signal in relation with the dosed amount of Hydrochloric acid. As indication of this pH/mV change, a pH glass electrode is used.
The obtained result dosed amount titre solution is used for the determination of Sodium hydroxide according to the following calculation:
Concentration NaOH (g/l) = (V HCI * t HCl / V Sample ) * Mw NaOH * x
With: V HCl = dosed volume (ml) titre solution, obtained by registering the change of pH/mV in function of the amount of Hydrochloric acid added during titration
t HCl = strength titre solution (M)
V Sample = volume (ml) Sample device
X = e.g. density, inversion g/l > mg/l
UTILITIES
SOFTWARE VERSION LOADED : HD V1.01
BURETTE - REFILL SPEED : 2
SIZE : ml
RECL.VOLUME: 2 ml
CONSTANT - 1 : 0,1 Strength Time solution (M)
2 : Sample volume (ml)
3 : 40.00 Mw NaOH(g/mol)
4 : Calc. Factor
5 : Concentration
Reference solution
6 : 0 Predose volume Buret
Macro (ml)
7
8
9
10 Sample volume
STIRRER - SPEED: 30 %
SERIAL INTERFACE- DATABITS: 8
STOPBITS: 1
PARITY: EVEN
BAUDRATE: 1200
INTERFACE: PRINTER
OUTPUT MAPPING:
OUTPUT 1: DIRECTED TO:
LOW LIMIT: 0
HIGH LIMIT: 100
OUTPUT 2: NOT AVAILABLE
ADJUST PACE
CALIBRATION PARAMETERS:
DEFAULT TEMPERATURE 20 °C
Parameter(s) measured Alkalinity (as NaOH)
Range 0.15 - 5% NaOH
Sample Volume ± 1 ml
Reagents - 0.1M HC1 titre solution
- Deionized water
- NaOH standard solution