The legal warranty period for our devices is 24 months from delivery date.
All used instruments of Labexchange are subject to a technical inspection before delivery and will be supplied only, when they function perfectly well. The verification and functionability is documented by a service report of an independent service company. The Labexchange Fullguarantee is 60 days from delivery date. Malfunctions occurring within the warranty period will be corrected by us free of charge. (Valid for countries within the EU and CH)
Our certificate of operativeness ensures a technically perfect condition.
You are on the safe side with our used laboratory and analysis systems! For even more security during the purchase, we are granting the Labexchange right of return.
Return your laboratory or analysis system simply without explanation.
Our special terms and conditions are to be applied:Labexchange right of return(https://www.labexchange.com/fileadmin/user_upload/pdf/downloads/en/Rueckgaberecht_08_18_E.pdf)
On demand, we verify the option of an extension of warranty for your device. If possible, the period of warranty is 6 months for 10 % extra charge and 1 year for 20 % extra charge on the list price. (Valid for DE, AT, CH, FR, NL, BE, LU, GB and IR)
Play it safe! We are pleased to offer you the installation of your laboratory equipment. Our qualified technicians install the device on your desired date in the laboratory, so that you can work quickly and safely with your new laboratory equipment.
The installation of the equipment by Labexchange brings further advantages. You thereby obtain a guarantee extension to 6 months and you have also the right to the Labexchange Repurchase Guarantee. You receive sensible laboratory equipment and analytical systems as well as much of the available laboratory hoods, already incl. installation.
* Required Fields
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country
Possible payment methods
Comment
DE, AT, CH
Payment by invoice, payment in advance
Payment by invoice is only possible for corporate clients.
NL, BE, LU
Payment by invoice is only possible for corporate clients
Other countries
Payment in advance
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
All articles are used articles, except an article is listed especially as a new device.
Status
Condition
Immediately available
Used
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.
Published
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.
New device
new
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.
manufacturer: Applied Biosystems
model: GeneAmp 5700
annotation: Dokumente engl .
The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.
GeneAmp 5700 Sequence detection system
Electrical Requirements
Power
The electrical supply (4 electrical outlets) should have a dedicated 2.0-kVA power line and ground or a 2.0-kVA power line with a line conditioner or uninterruptible power supply (UPS). The electrical receptacle must be located within 1.8 m (6 ft.) of the instrument rear panel.
Location Volts (AC) Frequency
Japan 100 ± 10% 50/60 Hz ± 1%
USA/Canada 120 ± 10% 50/60 Hz ± 1%
Europe (pre-1992) 220 ± 10% 50/60 Hz ± 1%
EC 230 ± 10% 50/60 Hz ± 1%
UK (pre-1992) 240 + 6%/10% 50/60 Hz ± 1%
Australia 240 + 6%/10% 50/60 Hz ± 1%
Grounding
Certain types of electrical noise are greatly exaggerated by poor or improper electrical ground connections. To prevent these problems, it is very important to have a dedicated line and ground between the instrument and building main electrical service.
Power Cords
The instrument is shipped with electrical cords that are compatible to standard electrical outlets as found in the United States, Japan, Australia, Europe (EC), and the United Kingdom (pre-EC).
Voltage Quality
Line voltage must be within ±10% or as specified above. High or low voltages may have adverse effects on the electronic components of the instrument. In areas where the supplied power is subject to fluctuations exceeding these limits, a power line regulator may be required.
Power Outages
The instrument has been designed to recover from short periods of power outage (loss) and continue operation, provided that the line voltage does not become excessively noisy before the outage. If increased protection during a power outage is desired, you may want to install an uninterruptible power supply (UPS). We recommend a capacity of 2.0 kVA . The UPS will involve a higher cost than a line conditioner.
Laboratory Environmental Requirements
Altitude
This instrument is for indoor use only and for altitudes not exceeding 2,000 meters (6,500 ft.) above sea level.
Temperature and Humidity
The laboratory temperature should be maintained between 1530 °C (5985 °F). The instrument can tolerate up to 80% relative humidity. Avoid placing the instrument adjacent to heaters or cooling ducts.
Pollution
The installation category (overvoltage category) for this instrument is II, and it is classified as portable equipment. The instrument has a pollution degree rating of 2, and may be installed in an environment that has non-conductive pollutants only.
Heat
The thermal output of the instrument is 5000 Btu/h (~1,500 W
Emission/ Immunity Statement
For European customers, any product marked with the CE label meets the European requirements for emission and immunity as defined in the EMC Directive 89/336/EEC and the Low Voltage Directive 72/23/EEC. This product meets Class A emission limits.
Laboratory Space Required
Dimensions and Weight
The GeneAmp 5700 Sequence Detection System requires at least 0.56 m (20 in.) vertical clearance and 1.22 m (4 ft.) horizontal bench space. The vertical clearance will accommodate the computer when its monitor is placed on top. This vertical clearance will also accommodate the sequence detector and thermal cycler, which mount on top of each other. The horizontal space will accommodate the computer, thermal cycler/optics, and a small electronics unit.
Component Width Depth Height Weight
Instrument 17 cm 52 cm 30.5 cm 9.2 kg
(excluding the (6.5 in.) (20.5 in.) (12 in.) (20.2 lbs.)
thermal cycler)
Thermal Cycler 52 cm 61 cm 30.5 cm 40.5 kg
( GeneAmp ® (20 in.) (24 in.) (12 in.) (90 lbs .)
9600)
Electronics Unit 11.5 cm 33 cm 15 cm 3.2 kg
(4.5 in.) (13 in.) (6 in.) (7 lbs.)
Computer 41 cm 41 cm 52 cm 20 kg
(incl. monitor) (20 in.) (20 in.) (20 in.) (44 lbs.)