Description:
Applied Biosystems GeneAmp PCR System. Consisting of DNA cycler 9600 and Sequence detector 5700. Block for 60x0,5 mL. Interface. Computer. Software pre-installed. Keyboard. Mouse. 230 V. 50 Hz. 5 A. CE mark.
Add to Offer List
More Information
Objektnummer B00023427
ID-number 23427
Object name Appl.Biosystems GeneAmp 5700
Status Lagergerät
Manufacture Appl.Biosystems
Shipping 10-14 working days

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

manufacturer:       Applied Biosystems

model:                   GeneAmp 5700

annotation:           Dokumente engl .

 

 

 

 

 

GeneAmp 5700 Sequence detection system

 

 

Electrical Requirements

 

Power

The electrical supply (4 electrical outlets) should have a dedicated 2.0-kVA power line and ground or a 2.0-kVA power line with a line conditioner or uninterruptible power supply (UPS). The electrical receptacle must be located within 1.8 m (6 ft.) of the instrument rear panel.

 

Location                    Volts (AC)                  Frequency

Japan                          100 ± 10%                  50/60 Hz ± 1%

USA/Canada              120 ± 10%                  50/60 Hz ± 1%

Europe (pre-1992)      220 ± 10%                  50/60 Hz ± 1%

EC                              230 ± 10%                  50/60 Hz ± 1%

UK (pre-1992)            240 + 6%/–10%          50/60 Hz ± 1%

Australia                     240 + 6%/–10%          50/60 Hz ± 1%

 

Grounding

Certain types of electrical noise are greatly exaggerated by poor or improper electrical ground connections. To prevent these problems, it is very important to have a dedicated line and ground between the instrument and building main electrical service.

 

Power Cords

The instrument is shipped with electrical cords that are compatible to standard electrical outlets as found in the United States, Japan, Australia, Europe (EC), and the United Kingdom (pre-EC).

 

Voltage Quality

Line voltage must be within ±10% or as specified above. High or low voltages may have adverse effects on the electronic components of the instrument. In areas where the supplied power is subject to fluctuations exceeding these limits, a power line regulator may be required.

 

Power Outages

The instrument has been designed to recover from short periods of power outage (loss) and continue operation, provided that the line voltage does not become excessively noisy before the outage. If increased protection during a power outage is desired, you may want to install an uninterruptible power supply (UPS). We recommend a capacity of 2.0 kVA . The UPS will involve a higher cost than a line conditioner.

 

 

Laboratory Environmental Requirements

 

Altitude

This instrument is for indoor use only and for altitudes not exceeding 2,000 meters (6,500 ft.) above sea level.

 

Temperature and Humidity

The laboratory temperature should be maintained between 15–30 °C (59–85 °F). The instrument can tolerate up to 80% relative humidity. Avoid placing the instrument adjacent to heaters or cooling ducts.

 

Pollution

The installation category (overvoltage category) for this instrument is II, and it is classified as portable equipment. The instrument has a pollution degree rating of 2, and may be installed in an environment that has non-conductive pollutants only.

 

Heat

The thermal output of the instrument is 5000 Btu/h (~1,500 W

 

Emission/ Immunity Statement

For European customers, any product marked with the CE label meets the European requirements for emission and immunity as defined in the EMC Directive 89/336/EEC and the Low Voltage Directive 72/23/EEC. This product meets Class A emission limits.

 

 

Laboratory Space Required

 

Dimensions and Weight

The GeneAmp 5700 Sequence Detection System requires at least 0.56 m (20 in.) vertical clearance and 1.22 m (4 ft.) horizontal bench space. The vertical clearance will accommodate the computer when its monitor is placed on top. This vertical clearance will also accommodate the sequence detector and thermal cycler, which mount on top of each other. The horizontal space will accommodate the computer, thermal cycler/optics, and a small electronics unit.

 

 

Component               Width              Depth                         Height                        Weight

Instrument                   17 cm              52 cm              30.5 cm                       9.2 kg

(excluding the              (6.5 in.)            (20.5 in.)          (12 in.)                         (20.2 lbs.)

thermal cycler)

 

Thermal Cycler           52 cm              61 cm              30.5 cm                       40.5 kg

( GeneAmp ®                (20 in.)             (24 in.)             (12 in.)                         (90 lbs .)

9600)

 

Electronics Unit          11.5 cm           33 cm              15 cm                          3.2 kg

(4.5 in.)            (13 in.)             (6 in.)                           (7 lbs.)

 

Computer                    41 cm              41 cm              52 cm                          20 kg

(incl. monitor)              (20 in.)             (20 in.)             (20 in.)                         (44 lbs.)

 

 

Product group: PCR