Sold

Appl.Biosystems Voyager-DE STR

ID-number: 009171
Status: Stock unit
Preis auf Anfrage
Excl. 19% VAT , excl. Shipping Cost
siehe Storeview
Description:
Applied Biosystems Voyager-DE STR Biospectrometry Workstation. MALDI-TOFMass Spectrometer with Reflector Analyzer. YoC.: 2000.Newprice: 296.550,- Euro
Quotation
siehe Storeview
More Information
Objektnummer B00009171
ID-number 009171
Object name Appl.Biosystems Voyager-DE STR
Status Stock unit

Product group: Mass spectrometers

We can't find products matching the selection.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Appl.Biosystems

Modell:            Voyager-DE STR

Kommentar:   Dokumente engl.

The Voyager-DE STR Biospectrometry Workstation (Figure 1-3) is a floor-standing MALDI-TOF (matrix-assisted laser desorption ionization time-of-flight) mass spectrometer that includes a reflector analyzer.

Figure 1-3 Voyager-DE STR Biospectrometry Workstation

Biospectrometry

Biospectrometry is the application of mass spectrometry in the field of the life sciences.

This field uses fast chromatographic techniques, enzymatic chemistries, and surface chemistries and combines them with mass spectrometry and advanced software to better enable biomolecular research and facilitate data interpretation.

Features

Features of the Voyager-DE STR Biospectrometry Workstation include:

•     High-speed digitizer options and laser rates for optimum sample throughput

•     Positive and negative ion detection

•     Modular horizontal design

•     High-performance reflector

•     Post-source decay (PSD) analysis capability

•     Linear or reflector mode operation

•     Ion path length:

•     Linear mode-2.0 meter

•     Reflector mode-3.0 meter

•     Timed ion selection

•     m/z range in excess of 300 kDa

•     Sensitivity to less than 5 femtomoles with dried droplet application

•     Variable two-stage ion source

•     Automated single-plate sample-loading system; sample plates of various formats available

•     Ion focusing lens technology for increased sensitivity (serial number 4154 and later)

•     Video camera and monitor for sample viewing

•     Low mass gate matrix suppression

•     Intuitive Microsoft® Windows NT-based software

•     Collision-induced dissociation (CID) option

•     Second laser option

This section describes:

• System components

• Mass spectrometer

• Vacuum System

• Front panel indicators

• Computer components

Parts of the Voyager-DE STR system include:

•     Mass spectrometer

A time-of-flight mass spectrometer, described in Section 1.6.2, Mass Spectrometer. The high-vacuum system of the mass spectrometer is described in Section 1.6.3, Vacuum System.

•     Computer/Data System

A computer that operates the Voyager control software and the Voyager processing software. You control the mass spectrometer using the computer.

•     Digitizer (not shown)

An analog-to-digital converter that allows the signal from the mass spectrometer to be transferred to the computer.

The standard digitizer provided is a 4 GHz digitizer.

•     Video monitor

A monitor that displays a real-time video image of the sample spot for examination during acquisition.

•     Control stick

A peripheral device that controls position of the sample plate in the mass spectrometer. Allows you to start and stop acquisition and transfer data to the processing software.

The parts of the Voyager-DE STR Biospectrometry mass spectrometer are shown in Figure 1-18.

Figure 1-18 Voyager-DE STR Mass Spectrometer

Table A-7 Voyager-DE STR Performance Specifications for Installation

Condition

Specification

Resolution (FWHM-Full Width at Half Maximum) in Delayed Extraction mode

Linear mode:

• ≥ 3,000 for Angiotensin I (1.3 pmol/µl)

• ≥ 3,500 for ACTH (18-39) (1.5 pmol/µl)

Reflector mode:

• ≥20,000 for bovine insulin (3.5 pmol/µl)

• ≥1,200 for E. coli Thioredoxin (2.75 pmol/µl)

• ≥12,000 for Angiotensin (2.0 pmol/µl)

• ≥12,000 for ACTH Clips

• ACTH 1-17 (2.0 pmol/µl)

• ACTH 18-39 (1.5 pmoi/µl)

• ACTH 7-38 (3.0 pmol/µl)

[M+H] + ion analyzed.

Signal-to-Noise Ratio

• ≥ 200:1 for IgG (0.6 pmol/µl)

• ≥ 100:1 for BSA (4 pmol/µl)

Sensitivity

Routine detection of 5 fmol of neurotensin with a signal-to-noise ratio >80:1

Table A-7 Voyager-DE STR Performance Specifications for Installation

Condition

Specification

Mass Accuracy in Delayed Extraction mode

(difference between the mean of six measurements and the theoretical mass of the sample)

Linear mode:

• External Calibration - 0.05%

• Internal Calibration - 0.02%

Reflector mode:

• External Calibration - 0.008%

• Internal Calibration - 0.001%

Mass Accuracy of Fragment Ions

+/- 1 Da

Resolution of PSD Precursor (Timed) Ion Selection

80

Table A-8 Voyager-DE STR Mass Spectrometer Specifications

Condition

Specification

Mass range

≥300,000 Da

Upper limit set by suitably ionized biomolecule.

Reflector

Single-stage with optimized optics for PSD Analysis

Flight tube (horizontal)

• Linear mode - 2.0 m

• Reflector mode - 3.0 m

Ion source

Two-stage

Ion source voltages

Tunable:

• Accelerating Voltage - Up to 25,000 V

• Grid Voltage - Range determined by Accelerating Voltage

Laser

Nitrogen, 337 nm, 3 ns pulse, 20 Hz maximum firing rate

Actual laser firing rate dependant on digitizer

Digitizer

2 GHz digitization for enhanced resolution

Table A-8 Voyager-DE STR Mass Spectrometer Specifications (Continued)

Condition

Specification

Vacuum system

• Dual differential turbomolecular pumping for ultrahigh vacuum

• Multi-vacuum gauge capability for independent monitoring of source and analyzer regions

Ion detection

Positive and negative

Sample analysis

• Automated single-plate sample-loading system; sample plates of various formats currently available

• Manual control using control stick or mouse

• Sequence Control software for automated analysis

Dimensions

• 34 inches (87 cm) deep

• 94 inches (239 cm) wide

• 46 inches (117 cm) high

Table A-9 Voyager-DE STR Miscellaneous Specifications

Condition

Specification

Environmental

• Operating temperature-10-25°C

• Relative humidity-10-80%, non-condensing

• Altitude-≤ 2,000 m (6,500 ft) above sea level.

• Installation category (overvoltage category)-II, classified as portable equipment.

• For indoor use only.

• Pollution degree rating-2, and may be installed in an environment that has nonconductive pollutants only.

Computer

Minimum configuration:

• Pentium III

  500 MHz, with 9 GB hard disk and 128 MB

  RAM (random access memory)

• 17-inch color monitor