Appl.Biosystems BioCad Sprint
Objektnummer | B00014150 |
---|---|
ID-number | 014150 |
Object name | Appl.Biosystems BioCad Sprint |
Status | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
Firma: Appl.Biosystems
The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.
Overview PerSeptive Biosystems BioCAD SPRINT P TM P System for Perfusion Chromatography is a Computer-aided chromatography system that integrates all aspects of biomolecule purification with Perfusion Chromatography technology.
The BioCAD SPRINT System is designed for:
Chromatographic method executionRoutine execution of chromatographic methods for the purification and analysis of biomolecules.
Systematic method developmentThe goal of method development is to optimize conditions for your application. Systematic method development makes it easy to identify variables that affect your application, systematically change the variables, observe the effects, and use the Information to optimize chromatographic conditions.
Features The BioCAD SPRINT System provides the following features:
SimplicityMicrosoft® Windows°-based software
that is intuitive and easy to use. You can efficiently
develop and execute separations for analytical and
preparative applications.
Full Process CapabilityFull capability from sample injection through fraction collection, including automated column washing and regeneration.
SpeedChromatographic separations in as little as one to three minutes, when using POROS® media and columns.
VersatilityMultiple injection mode options.
Gradient CapabilitySix-buffer/solvent capability, with simultaneous blending between any four buffers/solvents.
DetectionMonitoring of pH, conductiviry, dual-wavelength UVNis absorbance, fluorescence (optional), and system pressure.
TemplatesPredefined templates for systematic method development of some variables such as columns and sample.
Data AnalysisData analysis of single data fites or groups of data fites.
ChromatoCADTM Scale-up Design System SoftwareTool for studying the effects of changing conditions in a process method (optional).
Biopharmaceutical Manufacturing SoftwareCompliance with FDA GMP requirements (optional).
SCOUT Column SelectorAutomated multi-column switching device that allows flow to be diverted to any one of six attached columns (optional).
Parts of the System
The BioCAD SPRINT System is shown in Figure 1-2.
The BioCAD SPRINT System includes:
Front panel indicators and controls
Buffer/solvent and pump system
Sample loader
Columns and plumbing
Detector and monitors
Fraction collection
Computer components
Indicators The front panel includes LED (light emitting diode) indicators:
Power On/OffIndicates status of system power
Pump On/OffIndicates status of pump
Event MarkIndicates Status of Event Mark control
Lamp On/OffIndicates status of UV/Vis detector lamp
Controls The front Panel includes push-Button controls:
Pump On/OffTurns pump an and off
Event MarkMarks the electronic strip Chart recorder manually with an MRK notation
Lamp On/OffTurns UV/Vis detector lamp an and off
General Specifications
Condition |
Specification |
||
Weight |
255 pounds (116 kg) |
||
Dimensions |
36 Inches (91 cm) deep, 72 Inches (183 cm) wide, 36 Inches (91 cm) high (space required for system, Computer monitor, keyboard, and buffers) |
||
Pumping system |
Dual piston, positive displacement with 6 inlets, pressure safety, and built-in seal flush |
||
Flow rate |
0.2-60 ml/min Accuracy is +/- 1% of setpoint or 0.05 ml/min (whichever is greater) |
||
Maximum system pressure |
3,000 psi (204 bar, 20.4 MPa) |
||
Gradient capability |
Up to six solvents, with low-pressure quaternary blending in Percentage, Eluent, or pH blend modes with 0.1% increments. |
||
|
Compositional accuracy: ± 1 |
||
Sample handling |
Four injection modest ManualEliminates prime volume, needle port adapter included PumpUnlimited volume loading Integrated Autosampler (optional)Inject from multiple samples, with complete control over autosampler functions Direct Wire Autosampler (optional)Inject from multiple samples, control autosampler from autosampler front panel |
||
Column sizes |
POROS° Perfusion Chromatography° columns-2.1 to 27 mm diameter Conventional chromatography columnsno limit an column size |
||
Column configurations |
One column NOTE: Use up to six columns with optional SCOUT Column Selector. |
|
|
Fraction collection |
Integrated control of optional external fraction collectors, which accommodate tubes or larger bottles. Tube-to-tube switching time is 0.1 seconds with the Advantec fraction collector. |
|
|
Materials |
Biocompatible and solvent-resistantPEEK, Teflon®, Kel F°, Kynar°, sapphire, stainless steel, aluminum Oxide, ruby |
|
|
Auxiliary Inputs and Outputs |
Inputs-2 TTL Outputs-2 TTL |
|
|
Auxiliary driver Outputs |
Spareout LC-12 V (0.25 A) Spareout HC-24 V (1 A) |
|
|
Detection Specifications
Condition |
Specification |
||
Pressure |
Transducer an pump discharge-0 to 3,000 psi |
||
Auxiliary Input |
12-bit A/D for additional detector |
||
pH probe |
Range-2 to 12 pH units Flow Gell volume-50 NI |
||
Conductivity probe |
Range-0 to 200 mS Flow cell volume-7 pI |
||
UVNisible |
Model 201 (single wavelength)-190 nm to 800 nm Model 205 (dual wavelength) 190 nm to 800 nm (single wavelength range) 190 to 450 nm OR 366 to 700 nm (dual wavelength ranges) Flow cells available: Analytical-6 mm path length, 9 NI volume, 45 ml/min flow rate maximum Semi-prep 3 mm path length, 4.5 pI volume, 100 ml/min flow rate maximum |
|
|
Miscellaneous Specifications
Condition |
Specification |
Computer |
Minimum internal Pentium/100 MHz, 1.2 gigabyte hard disk drive, 16 megabyte RAM Irandom access memory), 3.5" floppy disk drive, 14" Super VGA color monitor, keyboard, and mouse |
Options |
17" or 21" color monitor, laser and color printers, SCOUT Column Selector, external detector (UV/Vis or fluorescence), fraction collector, autosampler, 28.8K bps modern and remote control software, Supervisorr"" Software (stand-alone software version), Biopharmaceutical Manufacturing Software, ChromatoCAD Scale-Up Design System Software, and kits of selected POROS columns |