Archive

Appl.Biosystems ABI 7500

ID-number: 019993
Status: Archived Product?The unit is no longer available.
Shipping:
Description:
Applied Biosystems Real Time PCR /RT-PCR ABI 7500. YoC 2008. Maintenance agreement
siehe Storeview
More Information
Objektnummer B00019993
ID-number 019993
Object name Appl.Biosystems ABI 7500
Status Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

manufacturer:       Applied Biosystems

model:                   7500

annotation:           Dokumente engl.

 

 

 

 

 

 

 

What is the Applied Biosystems 7500 Real-Time PCR System?

 

The 7500 System is a thermal cycler that performs real-time PCR analysis. It is validated for use with the Quantifiler TM Human DNA and Quantifiler Y Human Male DNA quantitation kits to determine the amount of human and/or male DNA that is contained within a forensic and database sample.

 

 

 

What is Real-Time PCR?

 

Real-time PCR measures PCR amplification as it occurs, cycle-by-cycle, allowing quantitative measurements to be made in the highly reproducible exponential phase of PCR, enabling extremely accurate and precise quantitation of DNA over a large dynamic range. Real-time PCR provides the highest sensitivity and widest dynamic range of all available nucleic acid detection systems. Real-time PCR using TaqMan® technology is widely regarded as the gold standard for DNA & RNA quantitation due to its reliability and the increased specificity obtained through using primers and a probe.

 

Laboratories use the Applied Biosystems 7500 Real-Time PCR System in conjunction with the Quantifiler Human DNA and Quantifiler Y Human Male DNA quantitation kits to deterrmine the amount of amplifiable total male and total human DNA in a sample to estimate the relative amounts of male and female DNA in sexual assault forensic samples. Results obtained from the 7500 system using the Quantifiler kits also provide an indicator of the potential presence of PCR inhibitors and/or confirm the presence or absence of DNA in a sample. In addition, the Quantifiler kits determine the optimal amount of DNA that should be used in downstream STR amplification reactions to achieve a complete, balanced STR profile.

 

 

 

Features

Benefits

Wide dynamic range detection

•

More precise results with minimal hands-on time

 

•

Minimizes repeat analysis

Minimized contamination

•

Closed tube format minimizes the risk of contamination and eliminates all post-PCR processing

Proven performance

•

Utilizes trusted and validated PCR technology

Validated for use with QuantifilerTM kits

•

Validation supports use of 7500 system for human identification applications

Additional data analysis features

•

Auto-baseline feature simplifies data analysis

 

•

Tool tips for easy identification of sample wells when viewing amplification plots

Intuitive software

•

Plate wizards guide user through all aspects of experimental set-up

 

 

 

 

 

 

 

 

Product group: PCR