APERA Instruments SX731 tragbares pH-/ORP-/Leitfäh
The SX731 from Apera Instruments is designed for laboratory-grade pH, redox potential (ORP), conductivity (EC), total organic solvent (TDS), salinity, and resistivity measurements for all general water solutions. Its compact design, dust and water resistance (IP57), and the included rugged carrying case make the SX731 ideal for field use, even in harsh environments. The integrated memory function allows for the storage and recall of 300 data sets. Possible applications include water treatment, environmental monitoring, beverage production, aquaculture, groundwater monitoring, surface water monitoring, and aquarium monitoring, among others.
The 201T-S pH/Temp. electrode included in the set enables fast and precise pH measurements thanks to its lithium glass membrane and ceramic diaphragm. The 2301T-S conductivity/Temp. electrode is based on our unique BPB (Brush-resistant Platinum Black) electrode technology and is characterized by its precision and wide measuring range (0–200 mS/cm). Both electrodes can also measure temperature thanks to an integrated thermistor and perform automatic temperature compensation when measuring pH or conductivity. For precise and reliable ORP determination, the 301Pt-S ORP electrode is included, which is equipped with a high-quality platinum sensor. It does not require calibration and is easy to clean.
- Equipped with the 201T-S pH electrode, the 301Pt-S ORP electrode and the 2301T-S conductivity/temp. electrode
- Precise, fast and reliable measurement of pH, redox potential (ORP), conductivity (EC), TDS, salinity, resistivity and temperature
- Easy switching between conductivity, TDS, salinity and resistivity
- Fast & easy 1- to 3-point pH calibration and 1-point EC calibration
- A special digital filter technology further improves the response time and measurement accuracy
- The integrated memory function allows the storage and retrieval of 300 data records
- Dust and water resistant to IP57, ideal for use in harsh environments
- Supplied as a complete test kit in a robust carrying case
Technical data
| PH value | Measuring range | (-2.00 to 19.99) pH |
| resolution | 0.1/0.01 pH | |
| accuracy | Instrument: ±0.01 pH; Total: ±0.02 pH | |
| Input current | =2×10 -12 A | |
| Input impedance | =1×10 12 O | |
| stability | ±0.01 pH/3h | |
| Temp. compensation | (0 to 100) °C (automatic) | |
| Redox potential (ORP) | Measuring range (mV/ORP/EH) | -1999mV to 0 to 1999mV |
| resolution | 1 mV | |
| accuracy | Device: ±0.1% FS, Total: ±15 mV | |
| Conductivity (EC) | Measuring range | Conductivity: (0.00 to 19.99) µS/cm, (20.0 to 199.9) µS/cm (200 to 1999) µS/cm, (2.00 to 19.99) mS/cm (20.0 to 199.9) mS/cm TDS: (0 to 100) g/L; Salinity: (0 to 100) ppt Resistivity: (0 to 100) MO·cm |
| resolution | 0.01/0.1/1 µS/cm; 0.01/0.1mS/cm | |
| accuracy | Device: ±1.0% FS, Total: ±1.5% FS | |
| Temp. compensation | (0 to 50) °C (automatic) | |
| Electrode constant | 0.1 / 1 / 10 cm -1 | |
| Reference temperature | 25°C, 20°C, and 18°C | |
| More | Storage space | 300 data groups |
| Memory values | Serial number, measured value, measuring unit and temperature | |
| Power supply | 2 AA batteries (1.5V x2) | |
| Dimensions and weight | Measuring device: (65×120×31) mm/180 g Complete set: (255×210×50) mm/1490 g | |
| Quality and safety certification | CE, ISO 9001:2015 | |
| IP protection class | IP57 |
A complete set contains:
- SX731 pH/ORP/Conductivity Meter
- 201T-S pH/Temp. Electrode
- 301Pt-S ORP electrode
- 2301T-S Conductivity/Temp. Electrode
- pH 4.00 calibration solution, 50 ml
- pH 7.00 calibration solution, 50 ml
- pH 10.01 calibration solution, 50 ml
- 1413 µS conductivity calibration solution
- Operating instructions
- 2x AA batteries
- screwdriver
- Carrying case
| Objektnummer | A00103029 |
|---|---|
| ID-number | 103029 |
| Object name | APERA Instruments SX731 tragbares pH-/ORP-/Leitfäh |
| Manufacture | APERA Instruments |
| Shipping | 4-6 weeks |
| Status | Nieuw |
Product group: pH-Measuring
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
|
Country |
Possible payment methods |
Comment |
|
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
|
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
|
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
|
Status |
Condition |
Comment |
|
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
| In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
|
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
|
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
|
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |