Analytical Supplies Incubator Vindon 5694 MS. Time 129 h. Outer dimension: HxWxD 2000x820x970 mm. Volume 530 L. 4 inlaid bottoms. 240 V. 50 Hz. 13 A. Temp.: 0-50°C.
siehe Storeview
More Information
Objektnummer B00020317
ID-number 020317
Object name Analytical Supplies Vindon 5694
Status Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

manufacturer :       Analytical Supplies

model :                   Vindon 5694

annotation :           Dokumente engl .

 

 

 

 

Analytical Supplies Limited

V indon Conditioning Cabinets

 

The Vindon Cabinet with controlled temperature, humidity and BS 950 daylight illumination.

 

The benefits for use in the textile industry

 

Vindon Cabinets have helped to solve a significant problem for the textile industry in achieving repeatability in colour matching and dying consistency.

 

The cabinets overcome problems in preparation of test samples created by changes in environmental conditions – including sunlight, temperature and humidity – which can alter the shading process and create “drift” away from the specified colour standard. By being able to set humidity, light and temperature at specified levels, fabrics can be prepared and tested in controlled conditions. A major benefit in improving quality control procedures.

 

Used in conjunction with a spectrophotometer, the cabinets provide a vital tool in testing and controlling colour standards where fabrics are manufactured or dyed in bulk.

 

Whilst the spectrophotometer helps to provide precise colour fingerprints the conditioning cabinets can ensure the same shade standard are met, time after time, at whatever location throughout the world the dyeing process is undertaken.

 

 

 

Humidity

Humidity is created by externally mounted ultrasonic transducers which, on the demand of the digital electronic controller, immediately provides a supply of pre-conditioned moist air to the chamber. This method ensures fast humidity equilibration times and makes it ideal for the speedy conditioning of textile samples.

 

Temperature

Air circulation is fan assisted to ensure uniformity and accuracy of humidity and temperature throughout the chamber.

 

Daylight Illumination to BS 950 Part I (D65)

This is created by special fluorescent tubes fitted internally to the door.

 

Elapsed Hour Timer

This records the time period of usage of the lights to assist in replacement frequency.

 

Water

The water is supplied from a 10 litre reservoir. The cabinet will use approximately 5 litres of water per day. A re-circulating water filter system ensures removal of particles. Clean deionised laboratory grade 2 water is required for the reservoir to (BS 3978: 1987) or (ISO 3936: 1987).

 

 

 

Technical Specification and Product Data

 

5694MS

 

Overall dimension (mm)

Height:            2000

Width:              820

Depth:                         970

 

Chamber dimensions (mm)

Height:            1400

Width:              700

Depth:                         540

 

Useable volume ( litres )

530

 

External finish

White painted

 

Internal finish

Lacquered aluminium with stainless steel base

 

Fan circulation

Yes

 

Digital control

Yes

 

Safety thermostat

Yes

 

Shelves supplied

4

 

Max shelves possible

20

 

Shelf sitze (W x D mm)

650 x 530

 

Doors

1

 

Electrical requirement

240V, 50Hz, 13A

 

Weight (kg)

155

 

Water requirement

Laboratory grade 2 (ISO 3936: 1987)

 

Daylight tubes (BS950) (D65)

2

 

Operating Temperature – Ambient

+10°C to +30°C

 

Temperature range

0°C to +50°C

 

Temperature fluctuation (over time)

±1°C

 

Temperature variation (over space)

±1·5°C

 

Humidity range

60% to 90% RH

 

Humidity fluctuation (@20°C)

±2% RH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 