Sold

AminoNova A200

ID-number: 024141
Status: Stock unit
Preis auf Anfrage
Excl. 19% VAT , excl. Shipping Cost
siehe Storeview
Description:
AminoNova amino acid analyzer A200. HPLC system focused on amino acid analysis. Automatic injection system. Detector. Column oven. Pump. Year 2004
Quotation
siehe Storeview
More Information
Objektnummer B00024141
ID-number 024141
Object name AminoNova A200
Status Stock unit

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:                  Knauer

Modell :                AminoNova A200

Kommentar:       Dokumente engl.

 

 

 

Specifications :

 

 

Elution Buffer System

Eluent carousel for eight 500 ml non-toxic, ready-made buffers:

• Five lithium acetate buffers ( Eluents A, B, C, D, and E)

• Column regenerant , lithium hydroxide ( Eluent F)

• Potassium acetate ninhydrin reagent

• Reactor wash solution

One eluent system for both hydrolysis and physiological analyses! Ninhydrin reagent and eluents have 1 year shelf-life

 

Automated Sample Injection System

Integrated XYZ-mechanism with stationary rack design 2 sample racks accommodate 120 standard, 1.5 ml vials Injection volume in 1 μ l increments from 1–40 μ l Sample cooling to 5°C ± 2°C; Five priority sample positions

 

Detectors

2 microphotometer detectors at 570 nm and 440 nm Measurement cell with 10 μ l volume, 10 mm pathlength

Measurement range in 2 sensitivity options, normal and high (10x) Analog output 0-4 V; Noise < 0.02 mAU ;

Drift < 0.01 mAU /hr Linearity error < 0.3% at 1 AU; < 2% up to 4 AU

 

Peltier Column Oven

New design provides for longer lifetime than A100 column oven Programmable from 20–80°C; accurate to 0.3°C Rapid temperature ramping up to 5°C/min

 

Postcolumn Reactor

PEEK 0.25 mm ID reactor coil inside reactor oven unit Programmable from 20–150°C; accurate to 0.5°C

 

Pump for delivery of eluent and ninhydrin reagent

Double piston pump with 10 ml pumphead , inert titanium inlays Flow rate 0.01–1.50 ml/min

(typical flow rate = 0.20 ml/min) Reproducibility of flow is better than 1% at 100 μ l/min Pulse dampener reduces baseline noise to < 0.3 mV/min (570 nm)

 

Instrument Control and Data Management

Total instrument control from 32-bit aminoControl software under Microsoft Windows 2000 environment

Data acquisition with ChromGate or EuroChrom software GLP features and 21CFR11 compliant (log file, data audit trail, etc) Analog signal output and RS-232 connector

 

Reproducibility, detection limit

Retention times 2% RSD; peak areas 5% RSD 15 pmol detection limit (sensitivity varies for diff. amino acids)

 

The Amino Acid Analyzer A200 is a dedicated, compact, and complete analysis system, developed exclusively

for the routine analysis of amino acids by post column derivatization with ninhydrin . It represents a significant advancement in facilitating the determination of amino acids:

 

• The buffer system and separation column are compatible for both hydrolysis and physiological analyses

• Innovative narrow-bore design results in shorter run times and less eluent and ninhydrin reagent consumption

• Sensitivity is approximately four times greater than the previous generation of postcolumn ninhydrin analyzers

• All components are easily exchanged for faster service turnaround time

• Delivers outstanding results at an exceptional price

 

The widely known and extensively used ion exchange postcolumn ninhydrin procedure allows detection of both primary and secondary amino acids with the highest resolution and accuracy. Sample preparation is kept to a minimum and the step-wise elution permits an optimal separation while assuring excellent reproducibility.

 

 

Complete instrument control is achieved through aminoControl software running under Microsoft Windows 2000. The aminoControl software’s user-friendly interface and graphical displays of program parameters make routine analysis with the A200 simple and fast. A status information screen is always visible and gives an instant report on the current instrument operation. Five prewritten analysis programs and space for 49 additional custom programs makes it easy to optimize the running parameters for complicated analyses.

 

• Three password-protected access levels provide for GLP compliance

• An automatically generated log file maintains a record of all user actions

 

Clinical, research, or routine analysis

 

The A200 was developed primarily for the routine analysis of feedstuffs, agricultural products, or quality control (pharmaceuticals, food products, etc.). Clinical and biomedical laboratories can also use the A200 with physiological samples to detect and diagnose metabolic diseases or to quantitate amino sugars, peptides, or any other ninhydrin -reactive compounds. Applications are available upon request.