Amersham Storm 860

ID-number: 012769
Status: Archived Product?The unit is no longer available.
Shipping:
Description:
Amersham Biosciences Phosphor FluorImager Workstation STORM 860. Complete Computer Workstation with latest version of analysis software. 2 exposure screens incl. cassettes.
siehe Storeview
More Information
Objektnummer B00012769
ID-number 012769
Object name Amersham Storm 860
Status Archiv

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

Firma:              Amersham

Modell:            Storm 860

Kommentar:   Dokumente engl.

The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.

STORM860-01.jpg

Storm™

  • Large format imaging systems for filmless autoradiography, fluorescence, and chemifluorescence imaging.
  • Filmless autoradiography based on proven PhosphorImager™ technology.
  • Direct red- and blue-excited fluorescence enable rapid and accurate quantitation using fluorescence- and chemifluorescence-based methods.
  • Five orders of linear dynamic range ensure accurate, publication-quality results on the first exposure.

Storm™ 860 Gel and Blot Imaging System offers filmless autoradiography, fluorescence and chemifluorescence imaging.

Storm™ Gel and Blot Imaging System delivers proven PhosphorImager™ capability for autoradiography, direct fluorescence for nucleic acid and protein gel analysis, and chemifluorescence for fast blot analysis. Storm™ uses storage phosphor screens instead of film to deliver high-resolution imaging and accurate quantitation of 14 C, 3 H, 125 I, 32 P, 33 P, 35 S, and other sources of ionizing radiation.

The system’s wide exposure range and accurate signal quantification yield publication-quality images on the first exposure. Storage phosphor screens are reusable and are not degraded by repeated exposure to laboratory levels of radioactivity. To reuse, simply expose a screen to the extra-bright light of Image Eraser light box (included with Storm™ systems). With direct fluorescence, Storm™ enables visualization and analysis of nucleic acid and protein gels just minutes after electrophoresis is complete. Gels are soaked in dye solution and then placed in the scanner for analysis. Molecules labeled with Cy5 can also be directly detected.

For chemifluorescence-based methods, Storm™ reads blots in minutes, without exposure to film. Quantification is simplified because, unlike film, Storm™ exhibits a linear response to fluorescent signal intensities.

Storm™ scans gels, blots, or mounted and unmounted storage phosphor screens up to 35 × 43 cm. All Storm™ systems come with ImageQuant™ TL.

TECHNICAL SPECIFICATIONS

Scan area 

35 × 43 cm 

Sensitivity (limit of detection) 

< 2 dpm/mm 2 for 14 C (200 and 100 µm only) using GP screen in a one-hour exposure. 

Pixel size 

200, 100, and 50 µm, selectable. The scanning laser beam is approximately 50 µm in diameter. 

Spatial resolution 

Autoradiography: 2 line pairs/mm for lines drawn with 14 C ink.
Blue-excited fluorescence, chemifluorescence:  2 line pairs/mm
Red-excited fluorescence: 4 line pairs/mm 

Uniformity 

± 5% relative standard deviation 

Pixel accuracy 

± 0.15% 

Data format 

16-bit (65 536 levels), TIFF 

Linear dynamic range  and linearity 

5 orders of magnitude (100 000:1) with less than 7.5% relative standard deviation for entire dynamic range. 

Light source 

Storm™ 820, 830, 840, and 860 use a red laser diode (635 nm). Storm™ 840 and 860 also use a blue LED (450 nm). 

External interface 

SCSI 

Software 

Scan control software for Windows™ operating system. 

Power requirements 

Storm™: 115/230 V, 50 - 60 Hz, < 150 W
ImageEraser: 115/230 V, 50
- 60 Hz, < 150 W 

Dimensions (W × D × H) 

Storm™: 76 × 76 × 38 cm
ImageEraser: 42 × 32 × 63.5 cm 

Safety certifications 

UL 3101, CAN/CSA C22.2 No 1010.1, EN 61010-1, EN60825-1, EN 61326, CE Marking (LVD 73/23/EEC EMC 89/336/EEC), CDRH (FDA) Subpart 21 CFR Ch.1-Part 1040. (Please contact your local GE Healthcare office for the latest list of certifications.) 

ARRAY1-01.jpg

Atlas™ Human cDNA array probed with 33 P-labeled cDNA. The hybridized array, containing 588 unique targets, was exposed to a storage phosphor screen for 2 days and imaged using Storm™ 840.

ARRAY3-01.jpg

Gene Discovery Array Human I probed with 32 P-labeled human cDNA. The 22 × 22 cm membrane array contained 18 394 non-redundant cDNA clones. The array was exposed to a storage phosphor screen for one hour and imaged using Storm™ 820.

SELECTION GUIDE - Storm™ System Capabilities

Storm™ Model

Storage phosphor
autoradiography

Direct red-excited
fluorescence

Direct blue-excited
fluorescence

820

 

 

830

 

840

 

860

Product group: Life science / Biotechnology

We can't find products matching the selection.
Back to Top
part-of-labexchange-group
Search engine powered by ElasticSuite
Smart Deals Smart Deals
Labprocure