Agilent G2880A

ID-number: 018387
Status: Stock unit
Preis auf Anfrage
Excl. 19% VAT , excl. Shipping Cost
siehe Storeview
Description:
Agilent Autosampler G2880A. Fitting for Agilent GC 6850. Tray with 27 positions. Additional positions for solvents and waste vessels. YoC 2004.
Quotation
siehe Storeview
More Information
Objektnummer B00018387
ID-number 018387
Object name Agilent G2880A
Status Stock unit

Product group: GC - Miscellaneous

We can't find products matching the selection.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

manufacturer :       Agilent

model :                   G2880A

annotation :           Dokumente engl .

 

 

 

The Agilent Technologies 6850 Automatic Liquid Sampler (ALS) is specifically designed for use with your 6850 Gas Chromatograph (GC). The sampler consists of an injector module with a high sample vial capacity turret. It mounts directly onto your 6850 GC and is controlled by your Agilent G2629A Control Module, Agilent Cerity NDS system, or Agilent ChemStation .

 

 

 

 

 

 

The 6850 ALS requires a 6850 GC with firmware revision A.03.xx or higher.

 

 

6850 ALS Capabilities

Your 6850 ALS comes with a turret that holds up to 27 2-mL sample vials. Also available is an optional turret holding up to 22 4-mL sample vials. With either turret, the 6850 ALS can use up to two bottles each of two solvent types, and uses three bottles for waste collection.

 

 

 

6850 Automatic Liquid Sampler Capabilities

 

General Options

Syringe size                             5, 10, 25, 50, and 100 µL

Injection volumes                    2%, 10%, 20%, 30%, 40%, or 50% of syringe volume

Syringe rinse solvents            Solvent A: two 4 mL bottles

Solvent B: two 4 mL bottles

 

 

 

Injection Parameter Control

 

Parameter                                         Range                                                Benefits

Variable sampling depth                     –2 to +30 mm above               Accesses very small

sample volumes

default position                        Accesses a specific layer in

a two-phase sample

Avoids aspirating sample

particulates

Pre-injection syringe                           0–15 rinses using                    Minimizes sample

carryover

rinsing and post-                                 solvent A and/or                      A pre-injection rinse wets

the syringe

injection syringe rinsing                      solvent B                                  without consuming sample

Sample prewashes                             0–15 prewashes                     An additional way to

minimize sample carryover

 

Injection Parameter Control

 

Parameter                                         Range                                                 Benefits

Viscosity delay, top of                         0–7 seconds                            Improves sampling plunger stroke                                                                                                   accuracy of viscous

samples

Pre-injection sample                           0–15 pumps                            Ensures accurate and

pumps                                                                                                reproducible sample

volume

Removes bubbles

Minimum sample                                0.1 µL (5-µL syringe)               Prevents overloading the

Injection volume                                                                                 column when using

( single injection)                                                                                 concentrated More information

For more detailed information, including operating procedures, general troubleshooting, and maintenance procedures, see your 6850 GC User Information CD-ROM.

13

  samples , on-

                                                                                                          column injections, or small-

                                                                                                          diameter columns

Maximum sample                               50 µL (100-µL                         Supports ambient

Injection volume                                  syringes)                                 headspace analysis

using gas-tight syringe

Injection plunger speed                       Fast/ Slow                                Fast plunger minimizes

needle

discrimination (see injection flow in vaporizing inlets rate table)

Slow plunger mimics manual techniques

Pre-injection dwell time                       0–1 minute                               Automatically fills needle

with 1 µL of air

after sampling            

Automates “hot needle” injection technique

Post-injection dwell                             0–1 minute                               Mimics manual injection

Time    

Injections per vial                                 1–99 injections                        For replicating sample

analysis

 

Injection Flow Rates

 

Syringe Size              Plunger Parameter (µL/min)

(µL)                              Fast                              Slow

------------------------------------------------------------------

5                                   3,000                            150

10                                 6,000                            300

25                                 15,000                         750

50                                 30,000                          1,500

100                               60,000                         3,000

 

 