Agilent G1312B
Objektnummer | B00018138 |
---|---|
ID-number | 018138 |
Object name | Agilent G1312B |
Status | Archiv |
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
Country |
Possible payment methods |
Comment |
DE, AT, CH |
Payment by invoice, payment in advance |
Payment by invoice is only possible for corporate clients. |
NL, BE, LU |
Payment by invoice, payment in advance |
Payment by invoice is only possible for corporate clients |
Other countries |
Payment in advance |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
Status |
Condition |
Comment |
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
manufacturer: Agilent
model: G1312B
annotation: Dokumente engl.
The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.
|
|
|||
|
|
Features
Configurable delay volume down to 120 µL together with a flow range up to 5 mL/min provides universal applicability.
Fast and easy change from standard to low delay volume configuration.
Electronic damping control for lowest baseline noise.
Perfect choice for fast and precise gradients using LC/MS, as well as UV-only systems.
Fully exploits the speed and separation potential of ZORBAX Rapid Resolution HT columns.
Specifications Agilent 1200 Series Binary Pump SL |
|
Hydraulic system |
Two dual piston in series pumps with proprietary servo-controlled |
Settable flow range |
Set points 0.001 - 5 mL/min, in 0.001 mlLmin increments |
Flow range |
0.05 - 5.0 mL/min |
Flow precision |
≤0.07% RSD, or ≤0.02 min SD whatever is greater, based on retention time at constant room temperature |
Flow accuracy |
± 1 % or 10 µL/min whatever is greater |
Pressure operating range |
0 - 600 bar (0 - 8700 psi) up to 5 mL/min |
Pressure pulsation |
Standard delay volume configuration: |
Compressibility compensation |
Automatic, pre-defined, based on mobile phase compressibility |
Recommended pH range |
1.0 - 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel |
Gradient formation |
High-pressure binary mixing |
Delay volume |
Standard delay volume configuration: |
Composition range |
Settable range: 0-100 % |
Composition precision |
≤0.15% RSD at 1 mL/min |
Composition accuracy |
± 0.35% absolute |
Control and data evaluation |
Agilent ChemStation for LC, EZ Chrom Elite |
Analog output |
For pressure monitoring, 2 mV/bar, one output |
Communications |
Controller-area network (CAN), RS-232C, APG Remote: ready, |
Safety and maintenance |
Extensive diagnostics, error detection and display (through Agilent LC Diagnostics), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. |
Housing |
All materials recyclable |
GLP features |
Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of seal wear and volume of pumped mobile phase with pre-defined and user-settable limits and feedback messages. Electronic records of maintenance and errors. |