Description:
Agilent Binary pump G1312B. With "active seal wash". As new. YoC 2006.
Quotation
siehe Storeview
More Information
Objektnummer B00018138
ID-number 018138
Object name Agilent G1312B
Status Stock unit

Product group: HPLC-Pumps (gradient)

We can't find products matching the selection.

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance, paymet by credit card

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance, payment by credit card

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance, payment by credit card

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

Labprocure

Used

Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen.

manufacturer:       Agilent

model:                   G1312B

annotation:           Dokumente engl.

 

 

Product Graphic

 

For Rapid Resolution LC 

The Agilent 1200 Series binary pump SL is part of the Agilent Rapid Resolution System and is optimized to cope with RRHT 1.8 µm particle size column technology. It is based on a high pressure mixing principle and is configurable in volume (standard or low delay volume configuration). The Agilent 1200 Series binary pump SL is the pump of choice for reproducible gradients and highest performance, especially at low flow rates, for high-throughput and ultra-fast applications, and the use of STM column technology. It is ideal for applications where high speed and resolution with uncompromised data quality is mandatory.

 

 

Features

*            Configurable delay volume down to 120 µL together with a flow range up to 5 mL/min provides universal applicability.

*            Fast and easy change from standard to low delay volume configuration.

*            Electronic damping control for lowest baseline noise.

*            Perfect choice for fast and precise gradients using LC/MS, as well as UV-only systems.

*            Fully exploits the speed and separation potential of ZORBAX Rapid Resolution HT columns.

 

 

Specifications Agilent 1200 Series Binary Pump SL

Hydraulic system

Two dual piston in series pumps with proprietary servo-controlled
variable stroke drive, floating piston design and active inlet valve

Settable flow range

Set points 0.001 - 5 mL/min, in 0.001 mlLmin increments

Flow range

0.05 - 5.0 mL/min

Flow precision

≤0.07% RSD, or ≤0.02 min SD whatever is greater, based on retention time at constant room temperature

Flow accuracy

± 1 % or 10 µL/min whatever is greater

Pressure operating range

0 - 600 bar (0 - 8700 psi) up to 5 mL/min

Pressure pulsation

Standard delay volume configuration:
< 2 %amplitude (typically < 1 %), at 1 mL/min isopropanol, at all pressures > 1 MPa
Low delay volume configuration:
< 5 %amplitude (typically < 2 %), at 1 ml/min isopropanol,
at all pressures > 1 MPa

Compressibility compensation

Automatic, pre-defined, based on mobile phase compressibility

Recommended pH range

1.0 - 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel

Gradient formation

High-pressure binary mixing

Delay volume

Standard delay volume configuration:
600-800 µL, dependent on back pressure (includes 400 µL mixer) Low delay volume configuration:
120 µL

Composition range

Settable range: 0-100 %
Recommended range: 1 - 99 % or 5 µL/min per channel, whatever is greater

Composition precision

≤0.15% RSD at 1 mL/min

Composition accuracy

± 0.35% absolute

Control and data evaluation

Agilent ChemStation for LC, EZ Chrom Elite

Analog output

For pressure monitoring, 2 mV/bar, one output

Communications

Controller-area network (CAN), RS-232C, APG Remote: ready,
start, stop and shut-down signals, LAN optional

Safety and maintenance

Extensive diagnostics, error detection and display (through Agilent LC Diagnostics), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.

Housing

All materials recyclable

GLP features

Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of seal wear and volume of pumped mobile phase with pre-defined and user-settable limits and feedback messages. Electronic records of maintenance and errors.

 