Agilent G 1310 A
For 1100 series.
230 V. 50/60 Hz. 180 W.
| Objektnummer | B00041664 |
|---|---|
| ID-number | 41664 |
| Object name | Agilent G 1310 A |
| Manufacture | Agilent |
| Shipping | 10-14 working days |
| Status | Stock unit |
Product group: HPPU
-
Agilent G 1310 A-20% discount
until Nov 30, 2025 Special Price €1,768.00 Regular Price €2,210.00Excl. 19% VAT , excl. Shipping Cost -
Gilson 334-15% discount
until Nov 30, 2025 Special Price €586.50 Regular Price €690.00Excl. 19% VAT , excl. Shipping Cost
Status, terms of delivery and payment
Verification of devices
The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.
Dispatch time
The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.
As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.
Shipping methods
Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.
Delivery information
Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.
The stated transport and packing charges apply to the most favorable route if transport and are to be understood as subject to verification due to unexpected cost increases. By reason of unpredictable events, cargo rates and delivery times can change at any time and therefore have to be adapted to the recent situation. Import formalities and possible customs charges will be borne by the purchaser. Incoterm coding according to Incoterms 2010: For persons who collect the devices themselves: EXW, for dipatch by sea: CFR, by air freight: CPT, other shipments: DAP. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.
Terms of payment
We do not accept payment by letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.
|
Country |
Possible payment methods |
Comment |
|
DE, AT, CH |
Payment by invoice, payment in advance, paymet by credit card |
Payment by invoice is only possible for corporate clients. |
|
NL, BE, LU |
Payment by invoice, payment in advance, payment by credit card |
Payment by invoice is only possible for corporate clients |
|
Other countries |
Payment in advance, payment by credit card |
|
Our General Terms of Sale, Delivery and Payment are valid and are available for download here.
The goods are offered subject to prior sale.
Definition of status
All articles are used articles, except an article is listed especially as a new device.
|
Status |
Condition |
Comment |
|
Immediately available |
Used | The article is fully functional and in impeccable condition. It can be shipped immediately. |
| In stock |
Used |
The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article. |
|
Published |
Used |
The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery. |
|
New device |
new |
The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply. |
|
Labprocure |
Used |
Labprocure GmbH, as the advertiser, is responsible for the content of this device offer. Labprocure assumes liability for the offers advertised here and for the photos and offer texts included. Labprocure GmbH, Bruckstraße 58, 72393 Burladingen. |
The following illustrations and descriptions are referring to the instrument model and are drawn from brochures. They are not representing the delivery volume. The exact delivery content you will find only in the offering text.
The Agilent 1100 Series isocratic pump
The isocratic pump is a work-horse designed to meet the needs of QA/QC applications:
Long Instrument uptimes that reduce operating and maintenance costs.
A wide flow range of up to 10 ml/min for broad HPLC work, including semipreparative separations.
Built-in early maintenance feedbackEMF, built-in seif-test routines and task-oriented online help are valuable features for QA/QC Operation.
Upgradeable to quaternary pump

One pump head containing dual pistons in-series and the active inlet valve for excellent baseline stability and reproducibility of retention times and peak areas

The isocratic pump delivers stable retention times, run after run, day after day.
Column: 125 x 4.0 mm ODS
Mobile phase: Water/acetonitrile 85:15
Flow rate: 1.5 ml/min

Built-in leak test with graphical presentation of pressure profile ensures reliable Operation

Full programming capabilityfor the isocratic pump
Intelligent method sequencing includes built-in shutdown methods to help reduce solvent costs and prolong column lifetime by flushing after a series of runs
Specifications
Flow precision: < 0.3 % RSD (typically <0.15%RSD)
Compressibility User-selectable, based
compensation: an mobile phase compressibility
pH range: 1.012.5 recommended
Control: 1100 Series control module or optional control by Agilent ChemStation for HPLC
Communications: Analog output: 2 mV/bar, for pressure monitoring, CAN-Bus, HP-IB, RS 232C, APG-remote standard. Optional 4 external contact closures.
Safety and
maintenance aids: Extensive diagnostics, error detection and display, leak detection and Safe leak handling, low voltages in major maintenance areas.
Housing: All materials recyclable
Env ironment: 455 °C constant temperature, <95 % humidity (non-condensing)
GLP features: Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of solvent usage with user-settable limits and feedback messages. Electronic records of maintenance and errors
Hydraulic System: Dual pistons in series, with proprietary servocontrolled variable stroke drive, floating pistons and active inlet valve
Flow range: Setpoints from 0.001 to 10.0 mI/min, in 0.001 ml/ min increments
Pressure: Operating range 040 MPa (0400 bar, 05880 psi) up to 5 mI/min; 020 MPa (0200 bar, 02950 psi) up to 10 mI/min
Gradient formation: Low-pressure quaternary mixing and gradient capability using proprietary high-speed proportioning valve. Delayvolume 8001100 µl, dependent an back pressure.
Composition < 0.20 % SD,at 0.2 and
precision: 1 ml/min
Dimensions (hxwxd): 140 x 345 x 435 mm (5.5 x 13.5 x 17 inches)
Weight: 11 kg (25 Ibs)