Description:
Agilent GC 7890B. With:
FID and PTV inlet.
Gerstel MPS with dual injector and head-space sampler.
Gerstel controller CF506.
Gerstel centrifuge CF 200.
Gerstel Cryo-Module UPCplus.
Gerstel mVorx orbital shaker.
PC with OpenLab software.
230 V. 50/60 Hz. 3450 W.
Installation
We execute the installation of this laboratory device professionally. We would be pleased to offer you the installation of this laboratory device for 2210€, excluding travel expenses.

Usually, laboratory and analysis devices are very exigent system with a very own specifications and requirements. Therefore, the startup of a laboratory device often rises the question how to assemble, adjust and to launch it.


We would be pleased to take over the professional installation of your laboratory devices!

Please contact us.


Benefit from the installation by us in more than one way:

  • Immediate and smooth startup of your laboratory device
  • A professional installation extends the lifetime of your laboratory device
  • Guarantee extends to 3 months
  • Freight charges do not apply*
  • You are entitled to benefit from the Labexchange Repurchase Guarantee.

* products of the product groups laboratory furniture and laminar flow are excluded. In individual cases, other product groups can be excluded.


Add to Offer List
More Information
Objektnummer B00036166
ID-number 36166
Object name Agilent 7890 B
Status Lagergerät
Manufacture Agilent
Shipping 10-14 working days

Status, terms of delivery and payment

Verification of devices

The second-hand devices are verified by Labexchange Service GmbH before delivery. You are receiving only fully functional devices.

Dispatch time

The stated dispatch times are the shortest possible ones for each article. The effective dispatch times can vary. The effective dispatch times will be stated in the order confirmation.

As a matter of principle, we are offering collective deliveries. The shipping time is calculated based on the position with the longest lead time. A partial delivery is possible on explicit request.

 

Shipping methods

Parcel services, forwarding agencies, self-pickup, delivery by Labexchange fleet.

 

Delivery information

Prices exclude shipping costs. Stated shipping costs are to be expected. Deviations are possible. If transport costs are not specified, please ask separately for them.

For deliveries to countries outside the EU, an additional fee of 70,00€ for export is charged. Note for international shipments: A proof of preference/EUR1 will not be issued by us. When self-collecting/ordering EXW from countries within or outside the European Union, 16% VAT will be retained as a deposit until we have received the corresponding confirmation of arrival/bill of delivery from the buyer.

 

Terms of payment

We do not accept payment by credit card, letter of credit, PayPal, etc. In each case the invoice amount is payable without deduction. Discount is not granted.

Country

Possible payment methods

Comment

DE, AT, CH

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients.

NL, BE, LU

Payment by invoice, payment in advance

Payment by invoice is only possible for corporate clients

Other countries

Payment in advance

 

 

Our General Terms of Sale, Delivery and Payment are valid and are available for download here. 

The goods are offered subject to prior sale.

 

Definition of status

All articles are used articles, except an article is listed especially as a new device.

Status

Condition

Comment

Immediately available

Used The article is fully functional and in impeccable condition. It can be shipped immediately.
In stock

Used

The article is on stock. Our service technicians will verify the article before delivery. You are receiving only a fully functional article.

Published

Used

The article is still with the provider. After your order the article will be purchased and verified by us before being shipped to you. A certificate of operativeness as well as a service report are included in delivery.

New device

new

The article is brand new and unused. Regarding new equipment the guarantee/warranty conditions of the corresponding manufacturer apply.

 

manufacturer:      Agilent

model:                  7890B

 

 

The following illustrations and descriptions refer to the instrument model and are drawn from brochures. They do not represent the scope of delivery. Please refer to the text of the offer for the exact scope of delivery.

 

Specifications

  • Height: 49 cm (19.2 in.)
  • Width: 58 cm (22.9 in.) with EPC inlet and detectors; 68 cm (26.8 in.). with third detector as TCD or with certain valving options mounted an left-hand side of GC

 

 

  • Depth: 51 cm (20.2 in.) Typical weight: 49 kg (108 113)
  • Four internal 24-volt connections (up to 150 mA)
  • Two external 24-volt connections (up to 150 mA)
  • Two on/off contact closures (48 V, 250 mA max)
  • 550 timed events via data system. 50 timed events via GC keyboard.
  • Support for up to 8 valves.- Valves 5 to 6, 24 V DC 100 mA unheated, for low power valve applications

 

 

    • - Valves 7 to 8, externally powered as a remote event from separate contact closure
    • - Valves 1 to 4, 12V DC 13 watt in a heated valve box
  • Independent heated zones, not including oven: six (two inlets, two detectors, and two auxillary). Third detector as TCD can utilize any available zone from inlet or auxillary zones.
  • Maximum operating teperatures for auxiliary zones: 400 °C

 

 

 

 

Environmental Conditions

  • Ambient operating temperature: 15 °C to 35 °C

 

  • Ambient operating humidity: 5% to 95% (noncondensing)
  • Storage extremes: -40 °C to 70 °C
  • Power requirements
  • Line voltage:120/200/220/230/240 Volts ±10% of nominal

 

 

  • Frequency: 50/60 Hz